Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were scanned using Computed Tomography (Initial scan). After canal preparation with ProTaper (group A), BioRaCe (group B), and Self Adjusting File (group C) the roots were rescanned (Final scan), the degree of canal transportation and centering ability were assessed at apical (4 mm), middle (6 mm), coronal (9 mm) sections using computed tomography. The collected data were statistically analyzed using ANOVA and Least Significant Difference tests. Results: There were no statistically significant differences among the groups at level 4 mm and level 9 mm (P ? 0.05). However, at level 6 mm there was a highly significant difference between (A) and (B) groups (P ? 0.01) and there was a significant difference between (A) and (C) groups (P ? 0.05). There were no statistically significant differences among different levels of (A) and (C) groups (P ? 0.05), while (B) group showed a highly significant difference between 4 mm and 9 mm levels and between 6 mm and 9 mm levels (P ? 0.01). Regarding canal centering ability, there was no statistically significant difference among the three groups at different levels (P ? 0.05)., while (B) group showed a significant difference between 4 mm and 9 mm levels (P ? 0.05), and a very highly significant difference between 6 mm and 9 mm levels (P ? 0.001). Conclusion: The study demonstrated that canal preparation with the three designs of Ni-Ti instruments produced canal transportation. Self Adjusting File group showed less canal transportation than ProTaper group. There was a comparable value of canal centering ability among different levels in each group except in BioRaCe group.
The Dirichlet process is an important fundamental object in nonparametric Bayesian modelling, applied to a wide range of problems in machine learning, statistics, and bioinformatics, among other fields. This flexible stochastic process models rich data structures with unknown or evolving number of clusters. It is a valuable tool for encoding the true complexity of real-world data in computer models. Our results show that the Dirichlet process improves, both in distribution density and in signal-to-noise ratio, with larger sample size; achieves slow decay rate to its base distribution; has improved convergence and stability; and thrives with a Gaussian base distribution, which is much better than the Gamma distribution. The performance depen
... Show MoreIn this research, some thermophysical properties of ethylene glycol with water (H2O) and two solvent mixtures dimethylformamide/ water (DMF + H2O) were studied. The densities (ρ) and viscosities (η) of ethylene glycol in water and a mixed solvent dimethylformamide (DMF + H2O) were determined at 298.15 K, t and a range of concentrations from 0.1 to1.0 molar. The ρ and η values were subsequently used to calculate the thermodynamics of mixing including the apparent molar volume (ϕv), partial molar volume (ϕvo) at infinite dilution. The solute-solute interaction is presented by Sv results from the equation ∅_v=ϕ_v^o+S_v √m. The values of viscosity (B) coefficients and Falkenhagen coefficient(A) of the Jone-Dole equation and Gibbs fre
... Show MoreIt is often needed to have circuits that can display the decimal representation of a binary number and specifically in this paper on a 7-segment display. In this paper a circuit that can display the decimal equivalent of an n-bit binary number is designed and it’s behavior is described using Verilog Hardware Descriptive Language (HDL).
This HDL program is then used to configure an FPGA to implement the designed circuit.
In this paper, the dynamic of quark and anti-quark interaction has been used to study the production of photons in the annihilation process based on the theory of chromodynamic. The rate of the photon is to be calculated for charm and anti-strange interaction c→γg system with critical temperature 113 and 130 MeV and photon energy GeV/c. Here the critical temperature, strength coupling and photons energy are assumed to be affected dramatically on the rate of photons emission of state interaction c, which can form gluon possible structures and photon emission state. The decreased photons emission yields with increased strength couple of quarks reaction due to increase critical temperature from 113 MeV to 130 MeV were predicted. We
... Show MoreThis study aims to Statement of the relationship between Total Quality Management philosophy and Organizational performance from the point of view of the internal customer. A comparison has been made between two companies, one of which applies the requirements of TQM well and the other does not apply these requirements as the (General Company for Electrical Industries/ Diyala) and (General Company for Electrical Industries/ Baghdad) to conduct the search, During the questionnaire prepared for this purpose and distributed to a sample of 30 employees in the General Company for Electric Industries/ Diyala and (20) employees of the General Company for Electrical Industries/ Baghdad. Their answers were analyzed using a simple correlation coef
... Show MoreElectrocardiogram (ECG) is an important physiological signal for cardiac disease diagnosis. With the increasing use of modern electrocardiogram monitoring devices that generate vast amount of data requiring huge storage capacity. In order to decrease storage costs or make ECG signals suitable and ready for transmission through common communication channels, the ECG data
volume must be reduced. So an effective data compression method is required. This paper presents an efficient technique for the compression of ECG signals. In this technique, different transforms have been used to compress the ECG signals. At first, a 1-D ECG data was segmented and aligned to a 2-D data array, then 2-D mixed transform was implemented to compress the
Background: The figure for the clinical application of computed tomography have been increased significantly in oral and maxillofacial field that supply the dentists with sufficient data enables them to play a main role in screening osteoporosis, therefore Hounsfield units of mandibular computed tomography view used as a main indicator to predict general skeleton osteoporosis and fracture risk factor. Material and Methods: Thirty subjects (7 males &23 females) with a mean age of (60.1) years underwent computed tomographic scanning for different diagnostic assessment in head and neck region. The mandibular bone quality of them were determined through Hounsfield units of CT scan images and were correlated with the bone mineral density v
... Show MoreThe sports field is one of the fields that are concerned with the various methods and methods because of their positive impact on the development of actual training, the investment of the exerted effort in time, and through the follow-up of the researcher in the field and academic field, I noticed that there is a weakness in explosive ability, which affects performance and skill level during training and competition Therefore, the researcher decided to prepare maximum physical exertion exercises according to the anaerobic threshold as a principle of development in many physical and skill variables because good physical performance leads to reaching the best achievements and since the skill of shooting by jumping high - either constitutes a
... Show More