Preferred Language
Articles
/
jbcd-2872
Comparison among pulp capping materials in: calcium ion release, pH change, solubility and water sorption (An in vitro study)
...Show More Authors

Background: Calcium hydroxide and calcium-silicate materials used as direct pulp capping materials. The aims of this in vitro study is to compare among these materials in, the calcium ion release and pH change in soaking water after immersion of materials’ specimens in deionized water. Also Solubility and water sorption of materials’ specimens measured after soaking time. Calcium-silicate materials used were Biodentine, TheraCal and MTA Plus. Materials and methods: Four materials used in this study; Urbical lining (as control group), Biodentine, TheraCal and MTA Plus. Ten discs fabricated from each tested material, by using plastic moulds of 9 mm diameter and 1 mm thickness. Each specimen was immersed in 10 ml of deionized water and stored at 37ºC using incubator for 3 hr, 24hr, 14 days and 30 days as a sequence. The amount of calcium ion (Ca+2) released in soaking water was measured in each tube using atomic absorption spectrophotometer. Also pH analysis for soaking water measured by using pH meter. For solubility and water sorption measurement, the specimen (n=10) weighed with precision weighing scale before immersion in deionzed water to determine the initial Weight (W1) and immediately after weighing immersed in 10 mL of deionized water at 37 °C for 1 week using an incubator, then removed and weighing again (W2). The samples blotted dry using filter paper and dehydrated in an oven at 37 °C for 24 hr. and weighed again (W3). Then percentage of solubility and water sorption were determined. Data obtained were analyzed using one-way ANOVA and Tukey tests at 0.05 significant levels. Results: Statistical analysis showed highly significant differences (P<0. 05) among tested materials and in all tests (Ca+2 release, pH change, solubility and water sorption). Biodentine showed higher calcium ion released at four soaking time (3 hr, 24hr, 14 days and 30 days), with non significant difference with TheraCal and highly significant difference with MTA Plus and control group at 24 hr. immersion time; While MTA Plus showed non significant difference with control group at 24 hr. Less amount of calcium released was in control group. All tested materials induced alkalization of the soaking water that decreased with time. Means of solubility and water sorption showed that MTA Plus and biodentine had higher solubility in comparison with control group, while TheraCal showed less solubility than control group. The results of water sorption showed that less sorption percentage occurred in control group in comparison with other groups. Conclusion: calcium-silicate materials released more Ca+2 with time than calcium hydroxide. TheraCal showed less solubility and higher water sorption in comparison with control group. Biodentine and MTA Plus showed higher solubility and water sorption in comparison with TheraCal and control group.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
Comparison between Open Mini-incision Thyroidectomy and Conventional Thyroidectomy: Clinical Experience and Literatures Review
...Show More Authors

Background: Thyroid surgery is most common endocrine surgery in general surgical practice. Objectives: the aim of this work is to evaluate the feasibility, benefits and outcomes of open mini-incision thyroidectomy and compared the results with that of conventional thyroidectomy. The comparison between the two groups was in term of incision length, amount of blood loss, time of operation, postoperative pain, hospital stay and the cosmetic outcomes.Type of the study: this is a single-blinded randomized controlled studyMethods: This study compared the advantages and outcomes of 22 patients subjected to mini-incision thyroidectomy (Group A) with the equal numbers of patients subjected to conventional thyroidectomy (Group B).Results: the oper

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Comparison of HF and HCl Chemical Laser Parameters by using Mathematical Model
...Show More Authors

A simplified theoretical comparison of the hydrogen chloride (HCl) and hydrogen fluoride (HF) chemical lasers is presented by using computer program. The program is able to predict quantitative variations of the laser characteristics as a function of rotational and vibrational quantum number. Lasing is assumed to occur in a Fabry-Perot cavity on vibration-rotation transitions between two vibrational levels of hypothetical diatomic molecule. This study include a comprehensive parametric analysis that indicates that the large rotational constant of HF laser in comparison with HCl laser makes it relatively easy to satisfy the partial inversion criterion. The results of this computer program proved their credibility when compared with th

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental and Numerical Comparison of Prestressed Perforated Concrete Rafters of Different Configurations
...Show More Authors
Abstract<p>This paper demonstrates an experimental and numerical study aimed to compare the influence of openings of different configurations on the flexural behavior of prestressed concrete rafters. The experimental program consisted of testing six simply supported prestressed concrete rafters; 5 rafters are perforated, and the other one is solid as a reference. All rafters were tested under monotonic midpoint load. The variable which has been investigated in this work was the opening’s configuration (quadrilateral or circular) with the same upper and lower chords depths. The results indicate improvement in the beam flexural behavior using the circular openings compared to the quadrilateral o</p> ... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
A comparison between PCA and some enhancement filters for denoising astronomical images
...Show More Authors

This paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used.

Experimental results shows LPG-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
On Comparison between Radial Basis Function and Wavelet Basis Functions Neural Networks
...Show More Authors

      In this paper we study and design two feed forward neural networks. The first approach uses radial basis function network and second approach uses wavelet basis function network to approximate the mapping from the input to the output space. The trained networks are then used in an conjugate gradient algorithm to estimate the output. These neural networks are then applied to solve differential equation. Results of applying these algorithms to several examples are presented

View Publication Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
Iraqi Journal Of Physics
A comparison between PCA and some enhancement filters for denoising astronomical images
...Show More Authors

This paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used. Experimental results shows LPG-PCA method

... Show More
Publication Date
Tue Mar 24 2009
Journal Name
Proceeding Of 3rd Scientific Conference Of The College Of Science, University Of Baghdad.
A Comparison Between Galactic and Large Magellanic Cloud (LMC) Interstellar Extinction Curves
...Show More Authors

Average interstellar extinction curves for Galaxy and Large Magellanic Cloud (LMC) over the range of wavelengths (1100 A0 – 3200 A0) were obtained from observations via IUE satellite. The two extinctions of our galaxy and LMC are normalized to Av=0 and E (B-V)=1, to meat standard criteria. It is found that the differences between the two extinction curves appeared obviously at the middle and far ultraviolet regions due to the presence of different populations of small grains, which have very little contribution at longer wavelengths. Using new IUE-Reduction techniques lead to more accurate result.

Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Removal of Amoxicillin from Water by Adsorption on Water Treatment Residues
...Show More Authors

The presence of residual antibiotics in water results in the development of antibiotics resistant genes. The available wastewater treatment systems are not capable of removing such antibiotics from sewage. Thus, antibiotics need to be removed before the discharge of wastewater. Adsorption is among the promising techniques for the wastewater treatment to aid the removal of a wide range of organic and inorganic pollutants. The present work is a contribution to the search for an economical method for the removal of low concentrations of amoxicillin (AMX) from water by adsorption on water treatment residue, WTR, taken from a local drinking water facility. The chemical composition and the adsorptive characteristics of the material were first

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Science
Calculating the variations of sunrise, sunset and day length times for Baghdad city.With comparison to different regions of the world in year 2019
...Show More Authors

     The sunrise, sunset, and day length times for Baghdad (Latitude =33.34º N, Longitude =44.43º E) were calculated with high accuracy on a daily basis during 2019. The results showed that the earliest time of sunrise in Baghdad was at 4h: 53m from 5 Jun. to 20 Jun while the latest was at 7h: 07m from 5 Jan. to 11 Jan. The earliest time of sunset in Baghdad was at16 h: 55m from 30 Nov. to 10 Dec. whereas the latest was at 19h: 16m from 25 Jun. to 5 Jul. The minimum period of day length in Baghdad was 9h: 57m) in 17 Dec. whereas the maximum period was 14h: 22m) in 20 Jun. Day length

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of some mechanical properties of ImprelonĀ® and DuranĀ® thermoplastic Biostar machine sheets in comparison with some types of acrylic resins
...Show More Authors

Background: Imprelon® Biostar foils are new alternative tray material that has become increasingly popular because oftheir several advantages. Also, (Duran®) is another type of Biostar foils which is used in splint therapy. This study assessed some mechanical properties of these two types Biostar sheets in comparison with some types of acrylic resins used for construction of trays and splints. Materials and Methods: A total of 150 specimens were prepared, 30 specimens for each test, 10 for each group material in order to assess some mechanical properties of the Imprelon® Biostar foil (dimension stability, surface roughness and shear bond strength of Imprelon® materialto zinc oxide impression material) and compare them to that of the oth

... Show More
View Publication Preview PDF