Comparison between diode laser and scalpel for lip lengthening in patients with gummy smile
...Show More Authors

Background: lip lengthening procedure is one of the surgical options for the correction of gummy smile in patients with short upper lip. Methods: A comparative clinical study was conducted on 15 patients requiring lip lengthening procedure for the esthetic correction of excessive gingival exposure with gummy smile. Scalpel was used in seven patients and diode laser in the remaining eight patients. Under infiltration anesthesia, about one cm strip of mucosa was excised at the vestibular depth and the mucosa of the lip was sutured to the alveolar mucosa. Results: The diode laser group demonstrated less postoperative pain and swelling. Regarding postoperative ecchymosis, three patients in the scalpel group developed ecchymosis and no cases were noted in the laser group, the difference was statistically significant. No patient in the laser group developed wound dehiscence and only one patient in the scalpel group had wound dehiscence at third postoperative day. Observed at one month postoperatively, the laser treated groups had less obvious scar than the scalpel group. Conclusion: Diode laser is a valuable tool in performing lip lengthening for gummy smile.

Scopus Crossref
View Publication
Publication Date
Fri Oct 01 2021
Journal Name
Ace Journal Of Clinical Chemistry And Laboratory Medicine
Comparison Between of Five Drugs Anti‐Virus for COVID‐19th in Chemicals Properties and Pharmacological Effectiveness: A Review
...Show More Authors

The corona virus epidemic outbreak has urged an extreme worldwide effort for re‐purposing obtainable approved medications for its treatment. In this review, we're focusing on the chemicals properties andpharmacologicaleffectiveness of medicationsofsmallmolecule that are presently being evaluated in clinical trials for the management of corona virus (COVID‐19). The current review sheds light on a number of drugs that have been diagnosed to treat COVID‐19 and their biological effects.

Publication Date
Tue May 05 2015
Journal Name
International Journal Of Research In Pharmacy And Chemistry
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit

... Show More
View Publication
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
A Comparison between High Ablative Versus Usual Dosages of Iodine-131 in Inducing Hypothyroidism After One Year of Therapy in Hyperthyroid Patients
...Show More Authors

Background: Radioactive iodine-131 therapy is highly effective in treating patients with hyperthyroidism. An ablative dose is preferred by a number of endocrinologists, and, a fixed dose protocol seems to be better than a calculated dose in real practice.

Objective: To check for hypothyroidism in hyperthyroid patients one year after RAI therapy, comparing between the results of high ablative versus usual dosages of RAI-131.

 Methods:  This study included 174 hyperthyroid patients, 101 males and 73 females, divided into 2 groups, the first consisted of 162 patients given a usual fixed dose of RAI while the second consisted of 12 patients given a high fixed ablati

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Influence of 805 nm Diode Laser on Plasmid Content of Some Locally Isolated Escherichia coli and Proteus Mirabilis
...Show More Authors

This work aimed to investigate the effect of Diode laser 805 nm on plasmid DNA and RNA
contents of some Gram negative bacteria represented by Escherichia coli and Proteus mirabilis isolates
.Plasmid extraction was done using two methods (Salting out and CTAB method).Different powers and
pulse repetition rates for 805 nm Diode Laser were used to study this effect. Results revealed that the
plasmid profile of the two species were highly affected using (2, 3) W at different frequencies including
5and 10 kHz as compared with 1 kHz while plasmids were gradually disappeared at 1W, 10 kHz. In the
same time the shining of RNA was also decreased gradually then disappeared with increasing powers
especially at 2W and 10 kHz cau

... Show More
View Publication Preview PDF
Publication Date
Thu May 04 2023
Journal Name
Journal Of Indian Association Of Biomedical Scientists
“Relationship between Cathepsin K and Total oxidative state in diabetes mellitus Iraqi Women patients with osteoporosis
...Show More Authors

Introduction and Aim: Diabetes mellitus patients almost always struggle with a metabolic condition known as chronic hyperglycemia. According to the World Health Organization, osteoporosis is a progressive systemic skeletal disorder that is characterized by decreasing bone mass and microstructural breakdown of bone tissue that increases susceptibility to fracture and increased risk of breaking a bone. Here, we aimed to compare the levels of CatK and total oxidative state in patients with diabetes and osteoporosis among the female Iraqi population and study the possible relationship between them. Materials and Methods: This study included 40 females with diabetes (Group G1), 40 with diabetes and osteoporosis (Group G2) and 40 normal healthy f

... Show More
Publication Date
Tue Mar 04 2008
Journal Name
Journal Of Baghdad College Of Dentistry
Twelve months clinical comparison between modified Widman flap with or without enamel matrix derivative for the treatment of infrabony defects
...Show More Authors

Publication Date
Wed Jul 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between powerful Waterpik flosser with dental floss as an adjunct to tooth brushing
...Show More Authors

Background: Removing dental plaque is important to maintain a good oral hygiene and prevent periodontal disease; this could not be accomplished by the use of toothbrush alone, it needs the help of interdental aids or intra-oral irrigator devices. The aim of this study was to compare the effect of using Waterpik flosser as adjunct to tooth brushing than using the dental floss with the brushing. Materials and methods: A single blind, six weeks study included 45 subjects divided into three groups of 15 subjects at each group. Group B (brushing) was instructed to use the toothbrush only, group BF (brushing & flossing) was instructed to use dental floss and tooth brushing while group BW (brushing and Waterpik flosser) was instructed to use Water

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 15 2023
Journal Name
International Journal Of Advances In Intelligent Informatics
An automatic lip reading for short sentences using deep learning nets
...Show More Authors

One study whose importance has significantly grown in recent years is lip-reading, particularly with the widespread of using deep learning techniques. Lip reading is essential for speech recognition in noisy environments or for those with hearing impairments. It refers to recognizing spoken sentences using visual information acquired from lip movements. Also, the lip area, especially for males, suffers from several problems, such as the mouth area containing the mustache and beard, which may cover the lip area. This paper proposes an automatic lip-reading system to recognize and classify short English sentences spoken by speakers using deep learning networks. The input video extracts frames and each frame is passed to the Viola-Jone

... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
An In Vitro Histological Study of Human Skin Wound Soldering Using 980 nm Diode Laser in Continuous versus Pulsed Modes.
...Show More Authors

Laser skin wound soldering offers many distinct advantages over conventional closure and laser welding techniques. Objective : to compare the histological effects of human skin wound soldering using 50 % human albumin solder and compound charcoal photosensitiser with 980 nm diode laser acting in various modes of action and parameters. Study Design/Materials and Methods: In this in vitro experimental study , Multiple 3-4 cm long full thickness incisions in a specimen of human skin were soldered using a 4 mm spot diameter beam of 980 nm diode laser(at different laser parameters and modes of action) with 50 % human albumin solder mixed with the compound charcoal at 5 % W/V concentration .After obtaining a successful wound soldering , the wo

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Comparison of HF and HCl Chemical Laser Parameters by using Mathematical Model
...Show More Authors

A simplified theoretical comparison of the hydrogen chloride (HCl) and hydrogen fluoride (HF) chemical lasers is presented by using computer program. The program is able to predict quantitative variations of the laser characteristics as a function of rotational and vibrational quantum number. Lasing is assumed to occur in a Fabry-Perot cavity on vibration-rotation transitions between two vibrational levels of hypothetical diatomic molecule. This study include a comprehensive parametric analysis that indicates that the large rotational constant of HF laser in comparison with HCl laser makes it relatively easy to satisfy the partial inversion criterion. The results of this computer program proved their credibility when compared with th

... Show More