The accuracy of ridge mapping procedure in determining the alveolar ridge width
...Show More Authors

Background: Post-extraction alveolar ridge resorption is unavoidable phenomenon ending with insufficient ridge width. Measuring the physical dimensions of the available bone before implant surgery is an important aspect of diagnosis and treatment planning. Bone height can be calculated from radiographs, while bucco-lingual ridge width can be measured by conventional tomography, CT scanning and ridge mapping.

Radiographic techniques have certain disadvantages. Therefore the ridge mapping technique was used as an option for determining alveolar ridge width.

The purpose of this study was to compare the validity of alveolar ridge width measurements obtained with ridge mapping technique before surgical flap reflection against direct caliper measurement following surgical exposure of the bone.

Materials and Methods: This prospective observational clinical study included 21 patients; 9 males (42.9%) and 12 females (57.1%) with mean age of 40.8. A vacuum formed acrylic stent was fabricated for each subject. The stent provided two buccal/lingual pairs of consistent measurement points to provide a reference of measurement for each implant site located 3 and 6 mm from the crest of alveolar soft tissue. Measurements (n=216) were made at 54 implant sites, the measurements obtained from the two techniques were compared and then accuracy of these methods was assessed. The mean, standard deviation, standard error of mean were calculated and subjected to statistical analysis using Student’s unpaired t- test, values <0.05 were considered statistically significant.

Results: There was no statistically significant difference between ridge mapping technique and intra-operative measurement in determining alveolar ridge width.

Conclusion: The ridge mapping technique is a useful method in determining alveolar ridge width for its exactitude, low cost, the immediate result and no need of radiation.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 05 2022
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Visual spatial attention and its impact on the accuracy of the diagonal spike in volleyball
...Show More Authors

The primary aim of this research was to study visual spatial attention and its impact on the accuracy of the diagonal spike in volleyball. A total of 20 volleyball players of Baghdad participated in this study. The sample was homogeneous in terms of height, weight and age of the players. The tests used in the present study were: 1) Visual Spatial Attention Test. 2) Volleyball Spike Test. Based on the findings of the study, the researcher concluded that visual spatial attention has a significant impact on the accuracy of the diagonal spike in volleyball.

View Publication Preview PDF
Crossref
Publication Date
Mon Nov 03 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The relation among ramal width and length with some cervical and cranio-facial measurements in different skeletal classes
...Show More Authors

Background: The purpose of this study was to assess the relation among the ramal length and width with various cervical and cranio-facial measurements for a sample of Iraqi adults with different skeletal classes. Materials and method: The sample composed of 71 Iraqi adults (36 females and 35 males) with an age ranged between 17-30 years and had different skeletal mal-relations using SNA, SNB and ANB to differentiate between them and assorting them into CL.I, CL.II and CL.III mal-relation. Each individual was subjected to clinical examination and digital true lateral cephalometric radiograph that had been analyzed using AutoCAD 2007 software computer program to determine sixteen linear and ten angular measurements. Descriptive statistics wer

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
Diagnostic Accuracy of Different Radiological Investigations in the Diagnosis of Perforated Duodenal Ulcer
...Show More Authors

Background; Perforated duodenal ulcer (PDU) is a common surgical emergency that is associated with high mortality and morbidity. Early diagnosis and prompt surgical treatment is required to prevent grave complications.
Objective; The study was designed to evaluate the diagnostic accuracy of different radiological investigations in the diagnosis of perforated duodenal ulcer.
Methods; A prospective study of 185 pts with PDU at al kindy teaching hospital, Baghdad, Iraq from June 2008- august 2010. patients were examined clinically and investigated by blood test, chest x ray, plain X ray of the abdomen. Ultrasonography (U/S) and CT scanning done for those patients with negative X- ray finding. Resuscitation by intravenous fluid and ant

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Determining the concentrations of radon and the rate of annual effective dose in some types of drinking water available in the Iraqi markets
...Show More Authors

           In this research, radon concentrations in some types of healthy drinking water samples available in Iraq's market were measured using a technique called Durridge RAD-7-H2O with closed loop. Then the rate of annual effective dose in human taken this water is determined.

          It was found that, radon concentrations in studied samples ranged between 1.2 Bq.m-3 to 142 Bq.m-3. The results of the radon concentrations and the rate of annual effective dose for drinking water samples were significantly lower than the USEPA and WHO recommended limits that equal 500 Bq/m3 and 1 mSv/y resp

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Oct 24 2017
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Analysing Building Shapes Quality of Collaborative Mapping
...Show More Authors

The very fast developments of web and data collection technologies have enabled non-experts to collect and disseminate geospatial datasets through web applications. This new type of spatial data is usually known as collaborative mapping or volunteered geographic information VGI. There are various countries around the world could benefit from collaborative mapping data because it is cost free data, easy to access and it provides more customised data. However, there is a concern about its quality because the data collectors may lack the sufficient experience and training about geospatial data production. Most previous studies which have outlined and analysed VGI quality focused on positional and linear features. The current research has been

... Show More
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in

... Show More
View Publication
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al- Mohtaref Journal
Impact of The Use of Electronic Concept Mapping Strategy in Learning and Retaining Some of The Skills of The Ground-Moving Carpet in Women's Artistic Gymnastics
...Show More Authors

The study aimed to identify the use of the electronic concept maps method in learning some of the skills of the floor exercises in the artistic gymnastics for third graders ,as well as to identify the best group between the two research groups (experimental And the officer to learn and retain some of the skills of the floor exercises in the artistic gymnastics of the research subject , and the experimental method was used and included the sample research on students of the collage of Physical Education and Sports Sciences/University of Baghdad, third grade, and has selected (10) Students for each group of The experimental and controlling groups randomly by lottery and after the completion of the period of implementation of the experiment wh

... Show More
Preview PDF
Publication Date
Thu Mar 25 2021
Journal Name
Engineering And Technology Journal
The Effect of the Number of Key-Frames on the Facial Emotion Recognition Accuracy
...Show More Authors

Key-frame selection plays an important role in facial expression recognition systems. It helps in selecting the most representative frames that capture the different poses of the face. The effect of the number of selected keyframes has been studied in this paper to find its impact on the final accuracy of the emotion recognition system. Dynamic and static information is employed to select the most effective key-frames of the facial video with a short response time. Firstly, the absolute difference between the successive frames is used to reduce the number of frames and select the candidate ones which then contribute to the clustering process. The static-based information of the reduced sets of frames is then given to the fuzzy C-Means algor

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Oct 14 2022
Journal Name
Diagnostics
Determination of the Accuracy of Salivary Biomarkers for Periodontal Diagnosis
...Show More Authors

Background: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15

... Show More
View Publication
Scopus (24)
Crossref (28)
Scopus Clarivate Crossref