Background: Cervical lymph nodes are prone to involved by a number of pathologic processes. They are common sites for lymphoma, metastasis, and reactive enlargement in a number of conditions. Aims of the study:-Clinical evaluation of patients with cervical lymphadenopathy. Differentiation between benign and malignant lymph nodes by means of ultra sounds (US) and Correlate the US findings with cytological and/or histopathological findings of cervical lymph nodes. Subjects, Materials and Methods:-The present study was carried out over a period of 6 months and included 81 patients of different age groups presenting with cervical lymphadenopathy. Each patient was examined clinically, then comprehensive sonographic examination of the neck for cervical lymph nodes (L.Ns) was performed using ultrasound machine (GE Wipro Proseries). The scanning was performed with the patient in the supine position, and with the neck hyperextended using a pad or pillow under the shoulders in order to provide optimum exposure of the neck. The parameters considered in this study include: site, long axis (L), short axis (S), shape index (S/L), echotexture, margins, ancillary features like calcification, necrosis, matting and surrounding tissue changes. These findings were correlated with fine-needle aspiration cytology, core and excisional biopsy. The nodes were classified as benign (reactive) and malignant (lymphomatous and metastatic). Results: The age of patients ranged from five to seventy five years, they were 45 male and 36 females, there was association between family history and development of malignant lesions. Regarding clinical evaluation, and according to consistency, (13) hard L.Ns were malignant and (1) was benign, (27) rubbery L.Ns were malignant and 40 soft L.Ns were benign. According to fixation to underlying structure, forty one L.Ns were fixed, (40) were malignant and (1) was benign. Forty L. Ns were not fixed, on histopathological evaluation all were benign. On US, the results showed that malignant lymph nodes are mostly appeared as round shape, homogenous echotexture, nodal shape (S/L ratio) accurate for differentiating benign from malignant lymph nodes. Most of the malignant nodes had well-defined borders. Calcifications, necrosis, matting, were characteristically found in benign lymph node. A combined ultrasound-guided and fine-needle aspiration (FNA) diagnosis had a high accuracy as compared with situations in which they were used alone. Conclusions: Sonographic findings have a high accuracy in differentiating benign from malignant cervical lymph nodes. An ultrasound scan can be used as the first-line imaging tool in the diagnostic evaluation of cervical lymphadenopathy. Using gray scale features are particularly useful to identify the causes of cervical lymphadenopathy.
Wireless Multimedia Sensor Networks (WMSNs) are a type of sensor network that contains sensor nodes equipped with cameras, microphones; therefore the WMSNS are able to produce multimedia data such as video and audio streams, still images, and scalar data from the surrounding environment. Most multimedia applications typically produce huge volumes of data, this leads to congestion. To address this challenge, This paper proposes Modify Spike Neural Network control for Traffic Load Parameter with Exponential Weight of Priority Based Rate Control algorithm (MSNTLP with EWBPRC). The Modify Spike Neural Network controller (MSNC) can calculate the appropriate traffi
... Show MoreObjective: Synthesized a series of new thiourea (TU) derivatives, tested their antioxidant activity, and investigated their expected biological activity by theoretical study (computational methods). Methods: The derivatives were made using a one-pot reaction with two steps. Initially, succinyl chloride was mixed with KSCN to make succinyl isothiocyanate. Then, primary and secondary amines were used to make TU derivatives. The theoretical studies were done by Swiss ADME and molecular docking via Genetic Optimization of Linkage Docking (GOLD). Then evaluate antioxidant activity using the DPPH scavenging method. Results: FT-IR, 1H NMR, and 13C NMR spectroscopy show the verification of all the prepared derivatives. Compounds (II), (VIII),
... Show MoreWellbore instability problems cause nonproductive time, especially during drilling operations in the shale formations. These problems include stuck pipe, caving, lost circulation, and the tight hole, requiring more time to treat and therefore additional costs. The extensive hole collapse problem is considered one of the main challenges experienced when drilling in the Zubair shale formation. In turn, it is caused by nonproductive time and increasing well drilling expenditure. In this study, geomechanical modeling was used to determine a suitable mud weight window to overpass these problems and improve drilling performance for well development. Three failure criteria, including Mohr–Coulomb, modifie
This study aims to show, the strength of steel beam-concrete slab system without using shear connectors (known as a non-composite action), where the effect of the friction force between the concrete slab and the steel beam has been investigated, by using finite element simulation.
The proposed finite element model has been verified based on comparison with an experimental work. Then, the model was adopted to study the system strength with a different steel beam and concrete slab profile. ABAQUS has been adopted in the preparation of all numerical models for this study.
After validation of the numerical models, a parametric study was conducted, with linear and non-linear Regression analysis. An equation re
... Show More