Background: Cervical lymph nodes are prone to involved by a number of pathologic processes. They are common sites for lymphoma, metastasis, and reactive enlargement in a number of conditions. Aims of the study:-Clinical evaluation of patients with cervical lymphadenopathy. Differentiation between benign and malignant lymph nodes by means of ultra sounds (US) and Correlate the US findings with cytological and/or histopathological findings of cervical lymph nodes. Subjects, Materials and Methods:-The present study was carried out over a period of 6 months and included 81 patients of different age groups presenting with cervical lymphadenopathy. Each patient was examined clinically, then comprehensive sonographic examination of the neck for cervical lymph nodes (L.Ns) was performed using ultrasound machine (GE Wipro Proseries). The scanning was performed with the patient in the supine position, and with the neck hyperextended using a pad or pillow under the shoulders in order to provide optimum exposure of the neck. The parameters considered in this study include: site, long axis (L), short axis (S), shape index (S/L), echotexture, margins, ancillary features like calcification, necrosis, matting and surrounding tissue changes. These findings were correlated with fine-needle aspiration cytology, core and excisional biopsy. The nodes were classified as benign (reactive) and malignant (lymphomatous and metastatic). Results: The age of patients ranged from five to seventy five years, they were 45 male and 36 females, there was association between family history and development of malignant lesions. Regarding clinical evaluation, and according to consistency, (13) hard L.Ns were malignant and (1) was benign, (27) rubbery L.Ns were malignant and 40 soft L.Ns were benign. According to fixation to underlying structure, forty one L.Ns were fixed, (40) were malignant and (1) was benign. Forty L. Ns were not fixed, on histopathological evaluation all were benign. On US, the results showed that malignant lymph nodes are mostly appeared as round shape, homogenous echotexture, nodal shape (S/L ratio) accurate for differentiating benign from malignant lymph nodes. Most of the malignant nodes had well-defined borders. Calcifications, necrosis, matting, were characteristically found in benign lymph node. A combined ultrasound-guided and fine-needle aspiration (FNA) diagnosis had a high accuracy as compared with situations in which they were used alone. Conclusions: Sonographic findings have a high accuracy in differentiating benign from malignant cervical lymph nodes. An ultrasound scan can be used as the first-line imaging tool in the diagnostic evaluation of cervical lymphadenopathy. Using gray scale features are particularly useful to identify the causes of cervical lymphadenopathy.
In this research, a novel synthesis of CaONPs has been developed via an environmentally friendly, green method. Garlic extract (Allium sativum) was used as a green-reducing and stabilizing agent for CaONPs. The average particle size of CaONPs was approximately 24.42 nm. The synthesized CaONPs were identified by using Fourier transform infrared (FT-IR) spectroscopy, U.V.-vis spectrum, X-ray diffraction (XRD), Field Emission-Scanning Electron Microscopy (FE-SEM), Transmission Electron Microscopy, transmission electron microscopy (TEM), Energy Dispersive X-ray spectroscopy (EDX), Atomic Force Microscopy (AFM), and zeta potential (Zp) analysis. The current study highlights the notable applications for CaONPs. First, an antimicrobial assay revea
... Show MoreSynthesis, characterization and pharmaceutical studies of schiff base from 2-pyrrolidinone derivative and imidazole-2-carboxaldehyde and corresponding complexes with Metal (||)
Most companies use social media data for business. Sentiment analysis automatically gathers analyses and summarizes this type of data. Managing unstructured social media data is difficult. Noisy data is a challenge to sentiment analysis. Since over 50% of the sentiment analysis process is data pre-processing, processing big social media data is challenging too. If pre-processing is carried out correctly, data accuracy may improve. Also, sentiment analysis workflow is highly dependent. Because no pre-processing technique works well in all situations or with all data sources, choosing the most important ones is crucial. Prioritization is an excellent technique for choosing the most important ones. As one of many Multi-Criteria Decision Mak
... Show MoreThe paper is devoted to solve nth order linear delay integro-differential equations of convolution type (DIDE's-CT) using collocation method with the aid of B-spline functions. A new algorithm with the aid of Matlab language is derived to treat numerically three types (retarded, neutral and mixed) of nth order linear DIDE's-CT using B-spline functions and Weddle rule for calculating the required integrals for these equations. Comparison between approximated and exact results has been given in test examples with suitable graphing for every example for solving three types of linear DIDE's-CT of different orders for conciliated the accuracy of the results of the proposed method.
This investigation reports application of a mesoporous nanomaterial based on dicationic ionic liquid bonded to amorphous silica, namely nano-N,N,N′,N′-tetramethyl-N-(silican-propyl)-N′-sulfo-ethane-1,2-diaminium chloride (nano-[TSPSED][Cl]2), as an extremely effectual and recoverable catalyst for the generation of bis(pyrazolyl)methanes and pyrazolopyranopyrimidines in solvent-free conditions. In both synthetic protocols, the performance of this catalyst was very useful and general and presented attractive features including short reaction times with high yields, reasonable turnover frequency and turnover number values, easy workup, high performance under mild conditions, recoverability and reusability in 5 consecutive runs without lo
... Show More