Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample include (60) Iraqi subjects (30 male and 30 females) aged between 20-65 years, sagittal view of Cone beam computed tomography was obtained to measure the height ,width and alveolar bone density of the mandibular anterior area, while coronal view was used to measure the height ,width and alveolar bone density assessment of the mandibular premolar and molar areas. Measurement of mandibular bony height and width was in(mm)and each of the three mandibular areas were represented by seven consecutive measurements for bony height and width and these seven stations were set using an average distance of 2 mm apart while the bone density in Hounsfield unit (HU) with point of measurement represent the mean of density to the area located between the height and buccolingual width. Results:The Statistical analysis of linear measurements of mandibular bone which include the bony height , width and density showed that the mean values of all three measurements are significantly higher in males than females also there was statistically significant difference in the mean bone density of mandibular areas which was highest in anterior area and lowest in the molar area followed by premolar area among both gender, mandibular bony height showed a statistically insignificant very weak negative linear correlation with age in all the three examined mandibular areas while the effect of age on bucolingual width was significantly higher among subjects older than 50 years compared to those younger than 50 years old. Conclusion: The mean bony height was highest in anterior area and lowest in premolar area followed by molar area, while the mean bony width was lowest in anterior area and highest in molar area followed by premolar area , finally the mean bone density was highest in anterior area and lowest in molar area followed by premolar area.
The electronic properties (such as energy gap HOMO levels. LUMO levels, density of state and density of bonds in addition to spectroscopic properties like IR spectra, Raman spectra, force constant and reduced masses as a function of frequency) of coronene C24 and reduced graphene oxide C24OX , where x=1-5, were studied.. The methodology employed was Density Functional Theory (DFT) with Hybrid function B3LYP and 6-311G** basis sets. The energy gap was calculated for C24 to be 3.5 eV and for C24Ox was from 0.89 to 1.6862 eV for x=1-5 ,respectively. These energy gaps values are comparable to the measured gap of Graphene (1-2.2 eV). The spectroscopic properties were compared with experimental measurements, specificall
... Show MoreThis experiment was conducted in the season 2001-2000 in station Ishaqi the company's general industrial crops to plant livestock Vigna radala deleted (Khadrawi) carried out the experiment design panels splinter and order in RCBD with three balls two factors are levels nitrogen fertilizer (120 and, 100.0 kg urea / ha)nitrogen ratio of 46%, which put in the main panels mAIN PLOT and Alkiavat three levels that were placed in secondary panels .....
Density data of alum chrom in water and in aqueous solution of poly (ethylene glycol) (1500) at different temperatures (288.15, 293.15, 298.15) k have been used to estimate the apparent molar volume (Vθ), limiting apparent molar volume (Vθ˚) experimental slope (Sv) and the second derivative of limiting partial molar volume [δ2 θ v° /δ T2] p .The viscosity data have been analyzed by means of Jones –Dole equation to obtain coefficient A, and Jones –Dole coefficient B, Free activation energy of activation per mole of solvent, Δμ10* solute, Δμ20* the activation enthalpy ΔH*,and entropy, ΔS*of activation of viscous flow. These results have been discussed in terms of solute –solvent interaction and making/breaking ability of so
... Show MoreBackground: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)
... Show MoreThis study aims to investigate the academic leaders’ perceptions towards the degree of availability of the dimensions of organizational immunity systems at the University of Tabuk, as well as to reveal the statistically significant differences between the average responses of the study sample members about the degree of availability of these dimensions at their university due to the variables of (gender, leadership position, and college specialization). To achieve the objectives of the study, a descriptive survey method was used. The study population consisted of (200) male and female leaders who were academic leaders at the University of Tabuk. A questionnaire was used as a tool for collecting data, which its validity and reliability
... Show MoreThe two-frequency shell model approach is used to calculate the
ground state matter density distribution and the corresponding root
mean square radii of the two-proton17Ne halo nucleus with the
assumption that the model space of 15O core nucleus differ from the
model space of extra two loosely bound valence protons. Two
different size parameters bcore and bhalo of the single particle wave
functions of the harmonic oscillator potential are used. The
calculations are carried out for different configurations of the outer
halo protons in 17Ne nucleus and the structure of this halo nucleus
shows that the dominant configuration when the two halo protons in
the 1d5/2 orbi
Numerical simulation of charge density produced in plasma actuators is dependent upon the development of models dealing with electrical properties. The main aim of this work is to investigate the characteristics surface charge density and space charge density of DBD plasma actuator. A simple design of surface dielectric barrier discharge plasma actuator is used in the study. The discharge gas was N2:H2 mixture with applied voltage equal to 1.5 kV. A theoretical plasma model is used to establish the charge density details. Results show that surface charge density increased in value and spread in width alone the exposed electrode as the voltage increased and reached to the amplitude value.
This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.5 mm, prepared to an ISO #15 diameter and taper. Canals were shaped using ProTaper Universal files (Dentsply Maillefer) attached to an X-smart Plus endo motor (Dentsply), set at 3.5 Ncm torque and 250 rpm, up to size S2 at working length. To simulate fractures, F2 and F3 files were weakened 3 mm from the tip, then twisted to break in the apical and middle sections of the canal, re
... Show MoreABSTRACT Background: Dental anomalies of teeth are major issue that contributes to dental problems encountered in general practice. The aim of this study is to measure the prevalence of dental anomalies and the associated etiological factors among 15 years old students in Basrah city –Iraq. Materials and methods: The total sample composed of 1000 students (435 males and 565 females) from urban area selected randomly from different high schools in the city. Diagnosis of dental anomalies were recorded by present or absent, diagnosis and recording of enamel defects were done according to the criteria of WHO (1997). Results: The prevalence of hypodontia was 4.6%, Females have higher prevalence than males (5.8% females and 3.0% males), ta
... Show More