Preferred Language
Articles
/
jbcd-2461
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample include (60) Iraqi subjects (30 male and 30 females) aged between 20-65 years, sagittal view of Cone beam computed tomography was obtained to measure the height ,width and alveolar bone density of the mandibular anterior area, while coronal view was used to measure the height ,width and alveolar bone density assessment of the mandibular premolar and molar areas. Measurement of mandibular bony height and width was in(mm)and each of the three mandibular areas were represented by seven consecutive measurements for bony height and width and these seven stations were set using an average distance of 2 mm apart while the bone density in Hounsfield unit (HU) with point of measurement represent the mean of density to the area located between the height and buccolingual width. Results:The Statistical analysis of linear measurements of mandibular bone which include the bony height , width and density showed that the mean values of all three measurements are significantly higher in males than females also there was statistically significant difference in the mean bone density of mandibular areas which was highest in anterior area and lowest in the molar area followed by premolar area among both gender, mandibular bony height showed a statistically insignificant very weak negative linear correlation with age in all the three examined mandibular areas while the effect of age on bucolingual width was significantly higher among subjects older than 50 years compared to those younger than 50 years old. Conclusion: The mean bony height was highest in anterior area and lowest in premolar area followed by molar area, while the mean bony width was lowest in anterior area and highest in molar area followed by premolar area , finally the mean bone density was highest in anterior area and lowest in molar area followed by premolar area.

Crossref
View Publication
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (8)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Revista Española De Cirugía Oral Y Maxilofacial
The correlation of alveolar trabecular bone microstructure with bone density measured by cone-beam computed tomography (CBCT) and implant stability
...Show More Authors

View Publication
Crossref
Publication Date
Tue Mar 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of alveolar bone height in adolescents utilizing Cone Beam Computed Tomography: a retrospective radiographic analysis
...Show More Authors

Background: To assess the alveolar bone crest level (ABCL) by Cone Beam Computed To-mography (CBCT) and to investigate several variables as predictors for the height of the alveolar bone in adolescents. Materials and methods: Age, sex, and ethnic groups were rec-orded for each patient. CBCT images were used to obtain measurements of the interproximal alveolar bone level from the cementoenamel junction (CEJ) to the alveolar crest. The highest measurement in each sextant was recorded along with any presence of a vertical bone defect or calculus. Results: Total of 720 measurements were recorded for 120 subjects. No vertical bony defects or calculus were observed radiographically. Statistically significant (P< 0.05) differences were observed be

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Craniofacial Surgery
Radiographic Assessment of Nasopalatine Canal Using Cone Beam Computed Tomography
...Show More Authors

View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Dec 23 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of bone density after six months from dental implants placement using Computed Tomography
...Show More Authors

Background: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and inc

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 23 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Computed tomography bone density in Hounsfield units at dental implant receiving sites in different regions of the jaw bone
...Show More Authors

Background: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one wee

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
J Indian Soc Periodontol.
Osteoporosis effect on posterior mandible in preimplanted area for postmenopausal females using cone-beam computed tomography
...Show More Authors

Scopus (1)
Scopus
Publication Date
Thu Dec 05 2024
Journal Name
Shifaa
Evaluating alveolar bone thickness in upper and lower incisors from orthodontic perspective. A Cone beam computed tomography-based retrospective study
...Show More Authors

Purpose: This study aimed to assess the thickness of alveolar bone of maxillary and mandibular incisors from orthodontics perspective. Materials and Method: A total of 73 Cone beam computed tomography for Iraqi patients (47 females and 26 males) were included in this study. The selected images were captured and imported to AutoCAD database software to perform the measurement. To measure alveolar bone thickness, a reference line was drawn through the long axis of each incisor, from the incisal edge to the root apex. Then, labial and lingual/palatal perpendicular lines were drawn to the reference line at 3, 6, and 9mm apically from the cemento-enamel junction (CEJ). Results: The buccal bone is generally thinner than the lingual/palata

... Show More
View Publication
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Anterior Loop Presence and Extension Using Cone-Beam Computed Tomography
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue May 03 2022
Journal Name
Teikyo Medical Journal
Tooth agenesis and palatal dimensions associated with craniofacial deformity- Cone Beam Computed Tomography based study
...Show More Authors

Cleft / palate is one of the common congenital deformities in craniofacial region, associated with different types of dental anomalies like (Tooth agenesis, impaction, and supernumerary teeth) with marked changes in palatal dimensions. This study aimed to determine the prevalence of teeth agenesis and dental anomalies in cleft lip/palate patients using CBCT, and to compare the palatal dimension of cleft group with control subjects. Twenty-eight cleft cases collected during the period from 2015 to 2022, CBCT images evaluated, the study sample classified into two groups (14 bilateral and 14 unilateral cleft lip/palate) and the non-cleft control group (14 CBCT images). The presence of dental anomalies was assessed in relation to clef

... Show More