Background: Fixed orthodontic appliances impede the maintenance of oral hygiene and result in plaque accumulation leads to enamel demineralization caused by acids produced by bacteria. Studies on plaque control strategies in orthodontic populations are limited. This might be caused by difficulties in the quantitative evaluation of dental plaque because the teeth have various levels of bracket coverage, and different tooth sizes and malocclusions, making the traditional categorical indices complex. The present study aims to evaluate the effect of different hygiene protocols on plaque quantity on bands with different attachments. Materials and method: Twenty patients had four bands within the orthodontic appliance. Then randomly divided into four groups of hygiene regimens where group A used chlorhexidine dentifrice, group B used fluoridated dentifrice, group C used chlorhexidine mouthwash along with chlorhexidine dentifrice and group D used chlorhexidine mouthwash in addition to the fluoride dentifrice. Bands were removed four weeks after the appliance been in place, cut out carefully into 2 pieces from the center of the mesial and distal contact areas, biochemical test (clinprocario L-pop) was applied then 80 digital photographs were obtained. Four areas of interest were estimated which are mesially and distally to each attachment (2 mm) in width each. Percentage of plaque in these areas was calculated and statistically analyzed. Results: Side difference revealed that the plaque accumulated on the right sided bands more than the left, however the difference was not significant. It was also found that the lower bands had insignificantly higher amount of plaque than the upper ones. Conclusions: The four groups of oral hygiene regimens have no significant different effects on the plaque amount. Moreover, the oral hygiene maintenance is more difficult in the right side than the left side but the difference was not significant. The lower arch accumulated insignificantly more plaque than the upper. Also, difference in attachments has no influence on plaque amount.
Background: The aims of this study were to evaluate the effect of implant site preparation in low-density bone using osseodensification method in terms of implant stability changes during the osseous healing period and peri-implant bone density using CBCT. Material and methods: This prospective observational clinical study included 24 patients who received 46 dental implants that were installed in low-density bone using the osseodensification method. CBCT was used to measure the bone density pre- and postoperatively and implant stability was measured using Periotest® immediately after implant insertion and then after 6 weeks and 12 weeks postoperatively. The data were analyzed using paired t-test and the probability value <0.05 was conside
... Show MoreThe melting duration in the photovoltaic/phase-change material (PV/PCM) system is a crucial parameter for thermal energy management such that its improvement can realize better energy management in respect to thermal storage capabilities, thermal conditions, and the lifespan of PV modules. An innovative and efficient technique for improving the melting duration is the inclusion of an exterior metal foam layer in the PV/PCM system. For detailed investigations of utilizing different metal foam configurations in terms of their convective heat transfer coefficients, the present paper proposes a newly developed mathematical model for the PV/PCM–metal foam assembly that can readily be implemented with a wide range of operating condition
... Show MoreBackground: One of the most prevalent procedures in oral surgery is the removal of impacted mandibular third molars, typically accompanied by trismus, edema, and pain. Several methods and biomaterials were implemented to mitigate or avoid these surgical problems. Objectives: To evaluate the efficiency of chlorhexidine gel (WISDOM®) in minimizing postoperative sequelae associated with the impacted mandibular third molar that will be surgically extracted and its role in promoting early soft tissue closure of the surgical site. Methods: The study design was a double-masked and randomized, controlled clinical study that included healthy patients needing the removal of a mandibular third molar through surgery. The participants were rand
... Show MoreThe increasing use of antiseptic compounds creates selective pressure cause emergence of antiseptic resistance among Staphylococcus aureus .Resistance mechanism of antiseptic is driven mainly by multi drug resistant (MDR) efflux protein.Sixty five isolates of S.aureuswere collected from different clinical sources and subjected to 11 antibiotics most of them are recognized by efflux systems as extruded substrates. Range of efflux activity was estimated using cartwheel method. Simultaneous discrimination of antiseptic coding genes (qacA/B, smr and norA)as well as nuc and mecA genes among multidrug resistantS.aureus(MRSA) isolates was preformed using multiplex PCR assay
... Show MoreCorrosion experiments were carried out to investigate the effect of several operating parameters on the corrosion rate and corrosion potential of carbon steel in turbulent flow conditions in the absence and presence of sodium benzoate inhibitor using electrochemical polarization technique. These parameters were rotational velocity (0 - 1.57 m/s), temperature (30oC – 50oC), and time. The effect of these parameters on the corrosion rate and inhibition efficiency were investigated and discussed. It was found that the corrosion rate represented by limiting current increases considerably with increasing velocity and temperature and that it decreased with time due to the formation of corrosion product layer. The corrosion potential shifted t
... Show MoreEnd Stage Renal Disease is a well-known global public health problem. Maintenance hemodialysis is considered a life-saving treatment for patients with such disease. This treatment method that requires patients to be adherent to hemodialysis attendance, dietary and fluid recommendations as well as adherence to prescribed medications to ensure success. The aim of the current study was to assess adherence, perception, and counseling among hemodialysis patients to different modalities of treatment (fluid restriction, dietary recommendations, medications, and hemodialysis schedules). A cross-sectional study carried out on hemodialysis patients who attended to the dialysis centers at al- Karama teachi
... Show MoreThe Makhoul Dam project proposed to be established is considered one of the strategic projects in Iraq as it works to insurance large quantity of water spare in flood seasons, increase the storage capacity of the dams in Iraq, as well as increase food security. The Makhool Dam is located on Tigris River in Salah al-Din Governorate, and 8 km south of the meeting point of the Tigris River with the Lower Zab River. The lake area is about 256 km2. In this research, a mathematical model was prepared by using HEC-RAS Two Dimension Software to analyze the velocity patterns and water depths inside makhool dam reservoir at the highest operational water elevation, based on the designs prepared
In this paper, the maximum likelihood estimates for parameter ( ) of two parameter's Weibull are studied, as well as white estimators and (Bain & Antle) estimators, also Bayes estimator for scale parameter ( ), the simulation procedures are used to find the estimators and comparing between them using MSE. Also the application is done on the data for 20 patients suffering from a headache disease.
ABSTRACT
Naproxen(NPX) imprinted liquid electrodes of polymers are built using polymerization precipitation. The molecularly imprinted (MIP) and non imprinted (NIP) polymers were synthesized using NPX as a template. In the polymerization precipitation involved, styrene(STY) was used as monomer, N,N-methylenediacrylamide (N,N-MDAM) as a cross-linker and benzoyl peroxide (BPO) as an initiator. The molecularly imprinted membranes and the non-imprinted membranes were prepared using acetophenone(AOPH) and di octylphathalate(DOP)as plasticizers in PVC matrix. The slopes and detection limits of the liquid electrodes ranged from)-18.1,-17.72 (mV/decade and )4.0 x 10-
... Show More