Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).
It is necessary to use the means of recovery and other means that help to get rid of the effects of fatigue, as the game of badminton and the effectiveness of running 800 meters fall within the mixed system with the superiority of the anaerobic system by more than the air system, so requires the development of energy systems In proportion to the time of the match for badminton players and their travels and high performance and ability to tolerate the high level of lactic acid in the muscles and blood and increase the pain associated with the fatigue that occurs during the performance. In light of the physical and physiological processes of these actions N it should seek through training programs to develop your endurance and wind energy sys
... Show MoreAbstract
In this study, we compare between the autoregressive approximations (Yule-Walker equations, Least Squares , Least Squares ( forward- backword ) and Burg’s (Geometric and Harmonic ) methods, to determine the optimal approximation to the time series generated from the first - order moving Average non-invertible process, and fractionally - integrated noise process, with several values for d (d=0.15,0.25,0.35,0.45) for different sample sizes (small,median,large)for two processes . We depend on figure of merit function which proposed by author Shibata in 1980, to determine the theoretical optimal order according to min
... Show MoreA spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples
... Show MoreThe article emphasizes that 3D stochastic positive linear system with delays is asymptotically stable and depends on the sum of the system matrices and at the same time independent on the values and numbers of the delays. Moreover, the asymptotic stability test of this system with delays can be abridged to the check of its corresponding 2D stochastic positive linear systems without delays. Many theorems were applied to prove that asymptotic stability for 3D stochastic positive linear systems with delays are equivalent to 2D stochastic positive linear systems without delays. The efficiency of the given methods is illustrated on some numerical examples. HIGHLIGHTS Various theorems were applied to prove the asymptoti
... Show MoreBackground: Coated aesthetic archwires are currently the existing solutions for the esthetic problem, but the color of these archwires tends to change overtime. This study was aimed to evaluate the color stability of different types of esthetic archwires from four different companies at different time periods after immersion of two different staining drinks which are tea and Pepsi cola. Materials and methods: 48 specimens were prepared, each specimen contains 10 aesthetic archwires; and were divided according to type of solution into two groups: A (tea) &B (Pepsi cola); each group contained 24 specimens (12 specimens were immersed in the staining solution as 4 specimens for each time intervals and 12 specimens were immersed in distilled wa
... Show More
In this study, the physical, and mechanical properties of low-cost and biocomposites were evaluated. The walnut shell and date palm frond fibers were thermally treated in an oven at a temperature of 70°C and then chemically treated with NaOH and distilled water solution, after these treatments, the biocomposite materials will be thermally treated again at 50°C. This procedure was performed for three types of biocomposite; Walnut shell Fiber Reinforced Polymer (WFRP), Date palm Fiber Reinforced Polymer (DFRP), and Hybrid Fiber Reinforced Polymer (HFRP), whereas the biocomposite sheets consisting of 30% biofibers and 70% unsaturated polyester, the mechanical test specimens were cut by a CNC machine according to ASTM standards. The e
... Show MoreOne of the important differences between multiwavelets and scalar wavelets is that each channel in the filter bank has a vector-valued input and a vector-valued output. A scalar-valued input signal must somehow be converted into a suitable vector-valued signal. This conversion is called preprocessing. Preprocessing is a mapping process which is done by a prefilter. A postfilter just does the opposite.
The most obvious way to get two input rows from a given signal is to repeat the signal. Two rows go into the multifilter bank. This procedure is called “Repeated Row” which introduces oversampling of the data by a factor of 2.
For data compression, where one is trying to find compact transform representations for a
... Show MoreIn this investigation, metal matrix composites (MMCs) were manufactured by using powder technology. Aluminum 6061 is reinforced with two different ceramics particles (SiC and B4C) with different volume fractions as (3, 6, 9 and 12 wt. %). The most important applications of particulate reinforcement of aluminum matrix are: Pistons, Connecting rods etc. The specimens were prepared by using aluminum powder with 150 µm in particle size and SiC, B4C powder with 200 µm in particle size. The chosen powders were mixed by using planetary mixing setup at 250 rpm for 4hr.with zinc stearate as an activator material in steel ball milling. After mixing process the powders were compacted by hydraulic
... Show More