Preferred Language
Articles
/
jbcd-2376
The Influence of Different Fabrication and Impression Techniques on the Marginal Adaptation of Lithium Disilicate Crowns (A comparative in vitro study)
...Show More Authors

Background: The marginal adaptation has a key role in the success and longevity of the fixed dental restoration, which is affected by the impression and the fabrication techniques .The objective of this in vitro study was to evaluate and compare the marginal fitness of lithium disilicate crowns using two different digital impression techniques (direct and indirect techniques) and two different fabrication techniques (CAD/CAM and Press techniques). Materials and Methods: Thirty two sound upper first premolar teeth of comparable size extracted for orthodontic reason were selected in this study .Standardized preparation of all teeth samples were carried out with modified dental surveyor to receive all ceramic crown restoration with 1 mm deep chamfer finishing line, 4 mm axial length and 6 degree convergence angle. Half of the teeth were duplicated and poured in type IV dental stone to have sixteen dies and then these dies and the remaining teeth divided in to two groups according to the type of digital impression techniques (n=16) as follow: Group A: Indirect digital impression technique scanned by inEos X5 camera; Group B: Direct digital impression technique scanned by CEREC AC Omnicam camera. Each group was subdivided according to the technique of fabrication into two subgroups (n=8): Press technique using IPS e-max press (A1, B1); CAD/CAM technique using IPS e-max CAD (A2, B2).Marginal gaps were evaluated on the prepared teeth at four defined points on each aspect using digital microscope at a magnification of (280X). One way ANOVA and LSD tests were used to identify and localize the source of difference among the groups. Results: The results showed that indirect digital impression with IPS e-max CAD/CAM group A2 revealed the poorest marginal integrity with (55.93 μm ± 3.300). Group B2 and group A1 were next in line with(44.49 μm ± 6.840 and 37.74 μm± 5.433) respectively, while in the first group of restorations, the result of 29.9 μm ± 5.534 obtained with direct digital impression with pressable ceramic was clearly better. Conclusions: All the tested digital impression techniques showed clinically acceptable accuracy and intraoral scanning with pressable ceramic significantly enhanced the marginal fit

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 24 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
The Incidence of Hepatitis C Virus Infections among People Screened in Governmental Health Care Facilities in 2018 in Iraq
...Show More Authors

View Publication
Crossref
Publication Date
Fri Jul 24 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
The Incidence of Hepatitis C Virus Infections among People Screened in Governmental Health Care Facilities in 2018 in Iraq
...Show More Authors

View Publication
Crossref
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Determination Of Micro Amount Of Spironolactone In Some Of Pharmaceutical Preparate By Using a Molecular Luminescence Technique.
...Show More Authors

The present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Prevalence of B-Thalassemia Carriers Among a Cohort of University Students in Hawler Province of Iraqi Kurdistan
...Show More Authors

         A representative sample of a thousand volunteer university students was screened for evidence of thalassemia minor.Complete blood counts using automated blood cell analysers and blood smears were examined. Patients having anemia, abnormal red cell indices or morphological features of thalassemia minor like hypochromia, microcytosis, target cells erythrocytosis and family history of thalassemia were then investigated for determination of  HbA2 & HbF levels. Estimation of hemoglobin A2 was performed by micro-column chromatography while HbF was done using alkali denaturation. Seventy seven out of the thousand samples tested positive for thalassemia minor. They all showed a hemoglobin A

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Engineering And Applied Sciences
Estimation of concentration of radioactive elements for the Liquid Waste pool in radiochemistry laboratories in Al Tuwaitha site Baghdad-Iraq
...Show More Authors

Scopus (3)
Scopus
Publication Date
Sat Dec 02 2023
Journal Name
International Journal Of Applied Engineering & Technology
ASSESSING THE CONCENTRATIONS OF SOME HEAVY METALS IN BLOOD SAMPLES OF CHILDREN DIAGNOSED WITH AUTISM SPECTRUM DISORDERS IN BAGHDAD CITY
...Show More Authors

Publication Date
Mon Sep 01 2014
Journal Name
Engineering And Technology Journal
Analysis of the Capacity, Spectral Efficiency and Probability of Outage of Adaptive Mobile Channel for WiMAX System
...Show More Authors

Preview PDF
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Properties of Ground-State of 17,19,20,24,26F using the Wave Functions of Harmonic-Oscillator and Spherical Hankel Functions
...Show More Authors

     The nuclear size radii, density distributions and elastic electron scattering charge form factors for Fluorine isotopes (17,19,20,24,26F) were studied using the radial wave functions (WF) of harmonic-oscillator (HO) potential and free mean field described by spherical Hankel functions (SHF) for the core and the valence parts, respectively for all aforementioned isotopes. The parameters for HO potential (size parameter ) and SHF were chosen to regenerate the available experimental size radii. It was found that using spherical Hankel functions in our work improved the calculated results quantities in comparison with empirical data.   

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
mathematical model for segmentation of the overall planning of puplic redemption company- ministry of industry and minerals
...Show More Authors

Abstract

The study presents a mathematical model with a disaggregating approach to the problem of production planning of a fida Company; which belongs to the ministry of Industry. The study considers disaggregating the entire production into 3 productive families of (hydraulic cylinders, Aldblatt (dampers), connections hydraulics with each holds similar characteristics in terms of the installation cost, production time and stock cost. The Consequences are an ultimate use of the available production capacity as well as meeting the requirements of these families at a minimal cost using linear programming. Moreover, the study considers developing a Master production schedule that drives detailed material and production requi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Iraqi Journal Of Agricultural Sciences
Effect of cultural media and nutrient solution on quality and production of cucumber by using hydroponic system.
...Show More Authors