Preferred Language
Articles
/
jbcd-2221
Color Stability of Different Aesthetic Archwires after Immersion into Different Types of Mouthwashes(An In Vitro Study)
...Show More Authors

Background: Because of the demands for aesthetic orthodontic appliances have increased, aesthetic archwires have been widely used to meet patient's aesthetic needs. The color stability of aesthetic archwires is clinically important, any staining or discoloration will affect patient’s acceptance and satisfaction. This study was designed to evaluate the color stability of different types of aesthetic archwires after immersion into different types of mouth washes. Materials and methods: Four brands of nickel titanium coated aesthetic arch wires: Epoxy coated (Orthotechnology and G&H) and Teflon coated (Dany and Hubit) were evaluated after 1 week, 3 weeks and 6 weeks of immersion into two types of mouthwashes (Listerine with alcohol and Listerine without alcohol). Color change measurements were performed by using spectrophotometer VITA Easyshade Compact according to the commission Internationale de I’Eclairage L*a*b* color space system. Results: The results of this study showed that there were highly significant differences in color change values among all brands of aesthetic archwires at various immersion media. On the other hand, a significant difference was found between Dany and Orthotechnology aesthetic archwires at 1 week immersion in distilled water. Listerine with alcohol mouthwash produced more color changes of aesthetic archwires and color change value increases with the time of immersion. Conclusions: All brands of aesthetic archwires showed different degrees of color changes but most of these changes were not visible or clinically acceptable.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 26 2022
Journal Name
Neuroquantology
Efficiency Evaluation of Optical System Includes Different Stop Apertures When Using Relative Moving Factor
...Show More Authors

In this work, optical system with different aperture shapes (circular, square, elliptical and triangle aperture) has been used for efficiency evaluation when the system involved moving factor in ideal case (aberration free). The optical system evaluate far moving object, therefore the image forming at image plane due to point spread function (image formula of incoherently illuminated point object). A mathematical treatment has been used to getting results by Gaussian numerical calculations method. The results show priority of circular aperture when optical system that submits of moving factor.

View Publication
Crossref (2)
Crossref
Publication Date
Fri Apr 13 2012
Journal Name
Kut Journal For Economic And Administrative Sciences
Using Different Methods to Estimate the Parameters of Probability Death Density Function with Application
...Show More Authors

In this paper, the maximum likelihood estimates for parameter ( ) of two parameter's Weibull are studied, as well as white estimators and (Bain & Antle) estimators, also Bayes estimator for scale parameter ( ), the simulation procedures are used to find the estimators and comparing between them using MSE. Also the application is done on the data for 20 patients suffering from a headache disease.

Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
The follow up of experimentally infected hamsters with Leishmania tropica immunized with different vaccines
...Show More Authors

Some parameters for advancement of Leishmania tropica infection were examined in three groups of golden hamsters, Group (1) inoculated with autoclaved killed Leishmania tropica , Group (2) inoculated with BCG vaccine alone while Group (3) Inoculated with mixed vaccine (autoclaved killed Leishmania with BCG). The follow up of experimentally infected animals with virulent isolation of Leishmania tropica was done for 90 days, the animals inoculated with mixed vaccine (autoclaved killed Leishmania with BCG) showed the minimum average in each of foot pad thickness (2.3 ± 0.05) mm after (60) days of infection, spleen enlargement (1.13±0.38) after (45) days of infection, spleen length (23.9±0.08) mm after (30) days of infection, liver weight(3.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 16 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Force decay of orthodontic elastomeric chains by using three different mechanisms simulating canine retraction
...Show More Authors

Background: The ideal force-delivery system must: provide optimal tooth moving forces that elicit the desired effects, be comfortable and hygienic for the patient, require minimal operator manipulation and patient cooperation and provide rapid tooth movement with minimal mobility during orthodontic therapy, the elastomeric chains have the greatest potential to fulfill these requirements. Materials and Methods: This in vitro study was designed to determine the effect of three different mechanisms for canine retraction : (6-3 , 6-5-3 and chain loop ) on the load relaxation behavior of three types of elastomeric chains : (maximum clear , maximum silver and extreme silver) from the same company (Ortho Technology company) with two different bran

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Co-digestion of Shumblan with Different Wastes as a Source for the Biogas Production
...Show More Authors

Shumblan (SH) is one of the most undesirable aquatic plants widespread in the irrigation channels and water bodies. This work focuses on boosting the biogas potential of shumblan by co-digesting it with other types of wastes without employing any chemical or thermal pretreatments as done in previous studies. A maximum biogas recovery of 378 ml/g VS was reached using shumblan with cow manure as inoculum in a ratio of 1:1. The methane content of the biogas was 55%. Based on volatile solid (VS) and C/N ratios, biogas productions of 518, 434, and 580 ml/g VS were obtained when the shumblan was co-digested with food wastes (SH:F), paper wastes (SH:P), and green wastes (SH:G) respectively. No significant changes of methane contents were observ

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 25 2018
Journal Name
Biomedical And Pharmacology Journal
Comparing the Impact Strength and Transverse Flexure Strength of Three Different Dentures Base Materials
...Show More Authors

View Publication
Crossref (9)
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Path Coefficient Analyses for Growth and Yield Traits of Barley Under Different Seeding Rates
...Show More Authors
Abstract<p>The purpose of this experiment was to determine the relationship between the path coefficient and seed rate for four different barley cultivars (Amal, Ibaa 265, Ibaa 99, and Buhooth 244) during the 2019-2020 winter season. The experiment was carried out using a split plot design with three replications according to a randomized complete block design (RCBD). The highest positive thru effect on grain yield was found for flag leaf area and harvest index at aseeding rate of 130 kg.h<sup>-1</sup>; the highest positive direct effect on grain yield was found for flag leaf area and plant height at aseeding rate of 160 kg.h<sup>-1</sup>; and the highest positive direct effe</p> ... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Wed Apr 30 2025
Journal Name
Iraqi Journal Of Science
Calculating the Variation of the Universal Parameter (Variable) Using Kepler's Equation for Different Orbits
...Show More Authors

Stumpff functions are an infinite series that depends on the value of z. This value results from multiplying the reciprocal semi-major axis with a universal anomaly. The purpose from those functions is to calculate the variation of the universal parameter (variable) using Kepler's equation for different orbits. In this paper, each range for the reciprocal of the semi-major axis, universal anomaly, and z is calculated in order to study the behavior of Stumpff functions C(z) and S(z). The results showed that when z grew, Stumpff functions for hyperbola, parabola, and elliptical orbits were also growing. They intersected and had a tendency towards zero for both hyperbola and parabola orbits, but for elliptical orbits, Stumpff functions

... Show More
Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Different Hand and Finger Grip Patterns using Surface Electromyography and Hand Dynamometry
...Show More Authors

Recording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different le

... Show More
View Publication
Crossref (7)
Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Viscosity Reduction of Sharqi Baghdad Heavy Crude Oil Using Different Polar Hydrocarbons, Oxygenated Solvents
...Show More Authors

This work studied the facilitation of the transportation of Sharqi Baghdad heavy crude oil characterized with high viscosity 51.6 cSt at 40 °C, low API 18.8, and high asphaltenes content 7.1 wt.%, by reducing its viscosity from break down asphaltene agglomerates using different types of hydrocarbon and oxygenated polar solvents such as toluene, methanol, mix xylenes, and reformate. The best results are obtained by using methanol because it owns a high efficiency to reduce viscosity of crude oil to 21.1 cSt at 40 °C. Toluene, xylenes and reformate decreased viscosity to 25.3, 27.5 and 28,4 cSt at 40 °C, respectively. Asphaltenes content decreased to 4.2 wt. % by using toluene at 110 °C. And best improvement in API of the heavy crude o

... Show More
View Publication Preview PDF