Background: The displacement of artificial teeth during complete denture construction presents major processing errors in the occlusal vertical dimension which were verified at the previous trial denture stage. The aim of this study was to assess the effect of delay in processing after final flask closure and tension application on the vertical acrylic and porcelain teeth displacement of complete dentures constructed from heat cured acrylic and the results were compared with the conventional processing method. Materials and methods: forty samples of identical maxillary complete dentures were constructed from heat polymerized acrylic resin. These samples were subdivided into the following experimental subgroups in which each subgroup contains 5 samples for both acrylic and porcelain teeth and as follows: 1. Conventional flasking technique and immediate processing. 2. Conventional flasking technique and 6 hours delay in processing. 3. flasking technique with tension system and immediate processing. 4. flasking technique with tension system and 6 hours delay in processing. Reference metal pins were attached to the middle of the buccal surface of the upper right canine and center of the buccal groove of the left first molar. And according to these reference points on the teeth another metallic Reference pins were fixed on the denture vestibules and at a distance of 7.5mm by straight lines and 6.5mm where placed between the metal pins and the vestibules in order to standardize the measurement. The distance between the right and left metal pins on the canine and molars and the corresponding metal pins on the buccal vestibules were measured during the wax up stage and after processing by using an optical travelling microscope with an accuracy of 0.0005 mm. Means in (mm) were analyzed statistically by analysis of variance and the comparative T-test and least significance test (LSD). Results: Significant reduction in vertical displacement of the teeth occurred in groups when 6 hours delay in processing were applied, but a significant improvement was also observed in groups with tension system application when compared with control group. On the other hand, there were a high significant reduction in the vertical displacement in groups with tension system and 6 hours delay in processing combination. While for the type of artificial teeth data showed significant difference in the amount of vertical displacement of the teeth in groups with acrylic teeth when compared with porcelain teeth. Conclusions: The findings of this study showed that 6 hours delay in processing and tension system application were effective in reducing the vertical displacement of the artificial teeth during flasking. The maximum reduction in the displacement was observed in dentures constructed from acrylic teeth. On the other hand, significant decrease in vertical displacement of the teeth was detected in dentures constructed from porcelain teeth.
Autorías: Nadeema Badr Mohammed, Missaa Nadem, Huda Badwe Shbeeb, Iqbal Abdul Hussein Neamah, Najlaa Abbas AL Zuhairi, Nihad Mohammed Alwan. Localización: Retos: nuevas tendencias en educación física, deporte y recreación. Nº. 63, 2025. Artículo de Revista en Dialnet.
Objective: The objective of this study is to develop instructional materials that teach fundamental basketball skills to female students enrolled in the first year of the College of Physical Education and Sports Sciences for Girls at the University of Baghdad while also encouraging reflective thinking (RT). Research methodology: the researcher chose the experimental methodology with the two equal group's method. Finding the community and choosing the right sample for the study's kind and goals are essential to the accomplishment of any research project. A sample for the primary experiment was picked at random after the researcher confirmed the students' first-year basketball curriculum. This study community consisted of (40) fourth-
... Show MoreBackground: This study was designed to measure the displacement pattern of posterior palatal seal (pps) area in different forms of the palate and with different impression techniques. Materials and method: This study was used to measure the displacement pattern of (pps)in different palatal shapes by using different impression materials Korrecta wax No.4,Green compound and design of House for pps for each palatal forms by using a 3D Scanner of CAD/CAM and measuring the distance between 2 points in pps area by using Caural Threw. Result: The results show highly significant differences between these techniques and the control group (impression with light body) Conclusion: The physiological impression technique of pps with Korecta wax no.4
... Show MoreProved Islamic banks in many countries where they are present, whether Muslim or non-Muslim in the wake of the global financial crisis, it is more efficient, profitable, and stable compared with the conventional banks, so went many of the worlds towards providing Islamic banking through Islamic windows to Besides financial services and products offered by the traditional, or the initiative to enter formulas Islamic finance is fully compliant with the principles and rules of Islamic law and is Brokerage basic function of conventional banks and Islamic alike ) and that means working on the mobilization of savings from surplus units and directed towards the financial units of the fiscal deficit) , which operates commercial banks
... Show MoreThree new polyphosphates were synthesized in good yields by reacting diethylenetriamine with the appropriate phosphate ester in ethanol under acidic conditions. The polyphosphate structures were determined using FT-IR and 1H-NMR spectroscopies, and their elemental compositions were confirmed by EDX spectroscopy. Polyphosphates were added to poly(vinyl chloride) (PVC) at low concentrations to fabricate thin films. The PVC films were irradiated with ultraviolet light for long periods, and the effect of polyphosphates as the photostabilizer was investigated by determining changes in the infrared spectra (intensity of specific functional group peaks), reduction in molecular weight, weight loss, and surface morphology. Minimal changes we
... Show MoreIn this paper, we will focus to one of the recent applications of PU-algebras in the coding theory, namely the construction of codes by soft sets PU-valued functions. First, we shall introduce the notion of soft sets PU-valued functions on PU-algebra and investigate some of its related properties.Moreover, the codes generated by a soft sets PU-valued function are constructed and several examples are given. Furthermore, example with graphs of binary block code constructed from a soft sets PU-valued function is constructed.
Background: Because of many factors play a role in the developing of late lower arch crowding, therefore the objective of the current study is to do vertical analysis for subjects with late lower dental arch crowding. The conducted study is the first attempt to do vertical analysis for Iraqi subjects with late lower arch crowding to see if there is a vertical discrepancy in such patients. Subjects and methods: Eighty subjects were selected according to certain inclusion criteria from patients attending the Orthodontic Department in the College of Dentistry, Baghdad University, patients ranged between 18-25 years old. The 80 patients were divided into two groups (crowding and normal), 40 patients each (20 males and 20 females). A study cast
... Show MoreObjective: To identify of the effect of the different concentrations of the special liquid (for mixing the investment, Gilvest)
and mixed with water/powder ratio on setting time of phosphate–bonded investment.
Method and materials: The present study is (60) specimens made from phosphate bonded investment divided into (4)
groups (control and experimental groups), (15) specimens for each group. The Gillmore needle device is used to setting
time of phosphate bonded investment mixed with different concentration of Gilvest and water.
Results: Showed that there is a high significant difference (P<0.01) between each groups in the ANOVA test and a
significant difference (P<0.05) between the group (A) and control group i