Preferred Language
Articles
/
jbcd-200
The value of ultrasound and color Doppler ultrasonography in the evaluation of periapical lesions in comparison to histopathological and/or surgical findings
...Show More Authors

Background: Imaging techniques play a very important role in the specialty of endodontic. The ultrasonographic technique is non-expensive procedure, safe, and reproducible. The aim of the study was to determine the sensitivity, specificity, and accuracy of ultrasound and color Doppler ultrasonography in evaluation of periapical lesions (cyst, granuloma, mixed lesion “cyst within graulomas mass”, and abscess. Subject, Material and method: The sample consists of prospective study for 64 Iraqi participants who attended Karbalaa Specialized Center for Dentistry (males & females). Those patients were diagnosed clinically and radiographically as having periapical lesions of dental origin. They were examined by real time ultrasound and color Doppler ultrasonography with echographic predilection about the type of the lesion based on three parameters measured by ultrasound including: content, outline, and the vascularity. The echographic diagnosis was compared to the final histopathological and /or surgical findings obtained from the periapical surgeries. Results: The sensitivity, specificity and accuracy of ultrasound diagnosis were respectively as follow: for periapical cyst, they were 92.3%, 96.1%, and 95.3%. While for periapical granulomam, they were 87.0%, 92.7%, and 90.6%. For mixed lesions, they were 66.7%, 98.4%, and 96.9% and lastly for periapical abscess, they were 92.0%, 97.4%, and 95.3%. The ultrasound diagnosis in our study had an overall agreement of 89% between ultrasound diagnosis and final diagnosis based on histopathological and/ or surgical findings. Conclusion: Ultrasound is a non- invasive, low cost, and complementary method for examination and diagnosis of periapical lesions and there is correlation of ultrasonographic findings with histopathological and /or surgical findings for final diagnosis.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Research Journal Of Pharmacy And Technology
New Mode Semi-Automated Turbidimetric Determination of Mefenamic Acid by Ayah 6SX1-ST-2D Solar cell-CFI Analyser
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Wed Oct 04 2023
Journal Name
Environmental Progress & Sustainable Energy
Removal of <scp>E133</scp> brilliant blue dye from artificial wastewater by electrocoagulation using cans waste as electrodes
...Show More Authors
Abstract<p>Solid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm<sup>2</sup>), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on </p> ... Show More
View Publication
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Applied Science And Engineering Progress
Efficient Separation of Organic Dyes using Polyvinylidene Fluoride/Polyethylene Glycol-Tin Oxide (PVDF/PEG-SnO2) Nanoparticles Ultrafiltration Membrane
...Show More Authors

This work studies developing ultrafiltration (UF) membranes using organic and inorganic additives to remove organic dyes at UF conditions with high effectiveness. Flat sheet (18 wt%) polyvinylidene fluoride (PVDF) membranes were prepared via phase inversion and then developed by adding 6 wt% polyethylene glycol (PEG) as a pore former. Furthermore, the PVDF/PEG membranes were developed by embedding tin oxide nanoparticles (SnO2 NPs) with different contents of 0.3, 0.6, and 0.9 wt%. The prepared membranes were examined for their performance in the dye removal before being characterized using the field emission scanning electron microscope, atomic force microscopy, contact angle, Fourier-transform infrared spectroscopy, surface charge,

... Show More
View Publication
Scopus (19)
Crossref (6)
Scopus Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Detection of Methamphetamine using Nanobentonite as a Novel Solid Phase Extraction Column Matrix Assisted with Gas Chromatography- Mass Spectroscopy
...Show More Authors

          This study was done to evaluate a new technique to determine the presence of methamphetamine in the hair using nano bentonite-based adsorbent as the filler of extraction column. The state of the art of this study was based on the presence of silica in the nano bentonite that was assumed can interact with methamphetamine. The hair used was treated using methanol to extract the presence of methamphetamine, then it was continued by sonicating the hair sample. Qualitative analysis using Marquish reagent was performed to confirm the presence of methamphetamine in the isolate.The hair sample that has been taken in a different period confirmed that this current developing method can be used to analyzed methamphetamine. This m

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Mar 21 2014
Journal Name
International Journal Of Antennas And Propagation
Development of a Compact Wide-Slot Antenna for Early Stage Breast Cancer Detection Featuring Circular Array Full-View Geometry
...Show More Authors

A novel planar type antenna printed on a high permittivity Rogers’ substrate is proposed for early stage microwave breast cancer detection. The design is based on a p-shaped wide-slot structure with microstrip feeding circuit to eliminate losses of transmission. The design parameters are optimized resulting in a good reflection coefficient at −10 dB from 4.5 to 10.9 GHz. Imaging result using inhomogeneous breast phantom indicates that the proposed antenna is capable of detecting a 5 mm size cancerous tumor embedded inside the fibroglandular region with dielectric contrast between the target and the surrounding materials ranging from 1.7 : 1 to 3.6 : 1.

Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Treatment of localized vitiligo with 1% pimecrolimus Cream versus 0.05% clobetasol propionate cream&#8212;single, blinded, comparative therapeutic trial
...Show More Authors

KE Sharquie, HR Al-Hamamy, AA Noaimi, KA Ali, Journal of Cosmetics, Dermatological Sciences and Applications, 2015 - Cited by 3

View Publication
Publication Date
Fri Jul 12 2024
Journal Name
Biomass Conversion And Biorefinery
Chitosan-triphosphate/food grade algae/montmorillonite clay for adsorptive removal of methyl violet 2B dye removal: Behnken design optimization
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Non-Destructive Damage Assessment of Five Layers Fiber Glass / Polyester Composite Materials Laminated Plate by Using Lamb Waves Simulation
...Show More Authors

Composite materials are widely used in the engineered assets as aerospace structures, marine and air navigation owing to their high strength/weight ratios. Detection and identification of damage in the composite structures are considered as an important part of monitoring and repairing of structural systems during the service to avoid instantaneous failure. Effective cost and reliability are essential during the process of detecting. The Lamb wave method is an effective and sensitive technique to tiny damage and can be applied for structural health monitoring using low energy sensors; it can provide good information about the condition of the structure during its operation by analyzing the propagation of the wave in the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 13 2018
Journal Name
Journal Of Engineering
Zn(II) Removal from Wastewater by Electrocoagulation/Flotation Method using New Configuration of a Split-Plate Airlift Electrochemical Reactor
...Show More Authors

In this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Kinetic studies of AST isoenzymes I,II,III,IV partially purified from patient,s urine with chroinc renal failure
...Show More Authors

In this research, the kinetic studies of four isoenzymes of Asprtate aminotransferase, which partially purified from the urine of chronic renal failure patients were carried out .The four isoenzymes were obeyed Michaelis-Menton's equation and the optimum concentration of their substrate (Aspartic acid) was (166.5x10-3) mole/liter,and their Km values were determined. Four isoenzymesI,II,III,IV have shown an optimum pH at 7.4.The four isoenzymes obeyed Arrhenius equation up to 37º C and their Ea and Q10 constants were determined .

View Publication Preview PDF
Crossref