Background: The aim of this study was to evaluate the effect of three types of light curing devices QTH, LED and Flashmax on the surface microhardness of three types of bulkfill composite resins; Filtek Bulkfill posterior composite ( 3M), Tetric Evo Ceram ( Ivoclar Vivadent) and Sonicfill composite ( Kerr) Materials and methods: Total number of 90 samples was prepared, 30 samples for each type of bulkfill composite, were divided into three main groups, group A: Filtek posterior bulkfil (3M), group B: Tetric Evo Ceram (Ivoclar Vivadent) and group C: contain Sonicfill composite (kerr). Which then divided into three subgroups (n= 10) (1) Samples cured by QTH system (2) Samples cured by LED system and (3) samples cured by Flashmax system then all samples were subjected for microhardness test (by Vickers hardness tester). The data were recorded and statistically analyzed, by the ANOVA and the Tukey test. Results: the data was subjected to statistical analysis using one way ANOVA and Tukey test, the result revealed that there was a high significant difference among the tested units with LED had high VHN values followed by QTH while Flashmax had lowest VHN values, also there was high significant difference among the tested materials in which Sonicfill composite had higher VHN value followed by Tetric EvoCeram while Filtek bulkfill posterior composite had the lowest VHN. Conclusions: microhardness of the composite resin materials depend upon energy of the curing device, time of exposure, composition of the composite material.
A field experiment was conducted in Yusufiya sub-district - Mahmudiya township/Baghdad governorate in silty loam texture soil during the spring season of 2020. The experiment included three treatments with three replicates, as the Randomized Complete Block Design (RCBD) was used according to the arrangement of the split design block. The treatments are in the irrigation system, which included surface drip irrigation (T1) and sprinkler irrigation (T2). Secondly, the Irrigation levels including the irrigation using 0.70 Pan Evaporation Fraction PEF (I1), irrigation using 1.00 PEF (I2), and irrigation using 1.30 PEF (I3). Coupled with, Pota
... Show MoreInformation and Communication Technology revolution has led to the emergence of electronic payment systems and their means And that the replacement of these modern means replace the traditional means (legal money) issued by the Central Bank has influenced the performance of monetary policy, especially that monetary policy is one of the most important policies used to achieve economic stability , The aim of the research is To know the impact of electronic payment systems on the tools of monetary policy as these means, such as cards and electronic money issued by credit institutions and companies, that is, the Central Bank is not responsible for issuance and spread And the lack of regulation by the Central Bank will lea
... Show MoreThe paper aims to propose the maximum track length (Lmax) measurement as an alternative approach to evaluate and extract the bulk etch rate (Vb) of the nuclear detector PADC CR-39, and compare it with the results obtained by the removal layer thickness measurement of the etched detector. The alternative Lmax-method mainly relies on the measuring the length of the etched tracks, their maximum values and saturation times from the obtained track profile images. The detectors were irradiated with different energies of alpha particles emitted from the 241Am source and then etched in a 6.5 N NaOH solution at 70±1oC for different successive time intervals. In
... Show MoreChoosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show MoreDental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. The disinfectant solutions of the impression materials cause various adverse reactions. Therefore, disinfection of dental casts may be effective in preventing cross infection. This study was carried out to evaluate the surface hardness, dimensional accuracy, reproduction of details and surface porosity of type III, type IV and type IV extra hard dental stone after immersion in and spray by using SOLO and Sodium hypochlorite disinfectant solutions. Materials and methods: 240 Stone samples were prepared in rubber rings, A total of 60 test block w
... Show More