ABSTRACT Background: work-related musculoskeletal disorders represent an important occupational health issues among dentists especially neck and low back complaints. Biomarkers of tissue damage as results of occupational physical demands could be used for detection of work related musculoskeletal disorders. Aim: The aim of this study was to assess work- related musculoskeletal disorders, physical work load index, selected salivary biomarkers (Creatine kinase and C - reactive protein) and to find the relation among them. Subjects and Methods: Study participants are consisted of 112 dentists. They were selected from college of dentistry /Baghdad University, health care center in Bagdad city. They were of both gender and aged between 40-45 years .they should fit the study criteria. Self-administered standardized Nordic questionnaires were used to evaluate musculoskeletal complaints. Physical work load was evaluated by used physical work load index. Stimulated saliva were collected from subsample (87) dentists drawn randomly from the total sample, for whom biochemical analysis (measurement of creatine kinase and C - reactive protein) were done. Results: Results showed that low back and neck complaints is the most complaint experienced by the dentists with percentages of ( 69.6% and 66.1% ), followed by the shoulder complaint (49.1% ) while the hip complaint showed the lowest percentage (13.4%).According to severity scores ,both low back and neck musculoskeletal complaints were of score 3 severity (score 3 constituted the highest percentages in both area (27.7% ,23.2%respectively) as compared to other severity scors.For shoulder complaint it was of score 2 severity (score 2 constituted the highest percentage 23.2% as compared to other severity scores, The musculoskeletal complaints(proximal ,neck, shoulder and low back) had higher mean rank values in the highest quartile of Physical work load index with non – significant differences (P<0.05). Regarding salivary creatine kinase the proximal ,total and low back complaints had higher mean rank values among dentists with highest Creatine kinase quartile , while distal manifestations ,neck and shoulder complaints had higher mean rank value in the average interquartile range of Creatine kinase with non – significant differences( P<0.05). For c- reactive protein almost all the complaints(proximal , total ,neck and shoulder) had higher mean rank values in the first lowest quartile with non – significant differences( P<0.05). Conclusions: Physical work load increase the risk of musculoskeletal disorders occurrence. Salivary creatine kinase could serve as a biomarker that reflects the underlying of musculoskeletal complaints more than C - reactive protein. Further studies that used more objective tools for assessing musculoskeletal disorders is needed.
In this research constructed N2 laser system by use developed method of electric discharge. In this method used four step of electric discharge by using four capacitors, three spark gaps, high tension power supply varying in range from 12kV to 24 kV and three resistors, this method called three stage blumlein circuit. The breakdown time delay of these parallel spark gaps cement strong ultraviolet preionization in the laser channel, thus the result of these amendments the laser output is many doubled and is more increasing than that obtained using the one and two stage blumlein circuits. This system has been designed and operated to give pulse laser with wavelength at 337.1 nm. This laser system can operate without mirrors and optical res
... Show MoreBootstrap is one of an important re-sampling technique which has given the attention of researches recently. The presence of outliers in the original data set may cause serious problem to the classical bootstrap when the percentage of outliers are higher than the original one. Many methods are proposed to overcome this problem such Dynamic Robust Bootstrap for LTS (DRBLTS) and Weighted Bootstrap with Probability (WBP). This paper try to show the accuracy of parameters estimation by comparison the results of both methods. The bias , MSE and RMSE are considered. The criterion of the accuracy is based on the RMSE value since the method that provide us RMSE value smaller than other is con
... Show MoreSupport vector machines (SVMs) are supervised learning models that analyze data for classification or regression. For classification, SVM is widely used by selecting an optimal hyperplane that separates two classes. SVM has very good accuracy and extremally robust comparing with some other classification methods such as logistics linear regression, random forest, k-nearest neighbor and naïve model. However, working with large datasets can cause many problems such as time-consuming and inefficient results. In this paper, the SVM has been modified by using a stochastic Gradient descent process. The modified method, stochastic gradient descent SVM (SGD-SVM), checked by using two simulation datasets. Since the classification of different ca
... Show MoreDue to restrictions and limitations on agricultural water worldwide, one of the most effective ways to conserve water in this sector is to reduce the water losses and improve irrigation uniformity. Nowadays, the low-pressure sprinkler has been widely used to replace the high-pressure impact sprinklers in lateral move sprinkler irrigation systems due to its low operating cost and high efficiency. However, the hazard of surface runoff represents the biggest obstacle for low-pressure sprinkler systems. Most researchers have used the pulsing technique to apply variable-rate irrigation to match the crop water needs within a normal application rate that does not produce runoff. This research introduces a variable pulsed irrigation algorit
... Show MoreAbstract
The research’s goal lies in demonstrating the impact of the Federal Financial Supervision Endowment through the process of auditing the performance of the entities subject to its audit as to improve the performance of these entities, especially if the performance audit method is one of the newly applied methods that are compatible with the standards issued by the International Organization of Financial Supervision and Accounting Institutions which is the method of auditing performance according to the performance evaluation guide for programs and policies issued by the Federal Office of Financial Supervision.
T
... Show MoreThree scolopacids out of 150 are found infected with Haemoproteus scolopaci Galli-
Valerio 1929 and H. tringae n. sp. A detailed description of the new taxon is presented along
with a comparison of the diagnostic measurements between the two species.
BN RASHİD, 2023
Double drum dryer is operated for producing pregelatinized maize starches using feed starch slurries of different
solids(7, 10 and13 g/100 g )content . Steam pressure (2,3,and 4 bar), the level of pool between the drums (4,7,and 10
cm) , and speed of drums rotation (3,4,and 6 rpm) are varied together with the feed solids content in a practical range of
values. The response of the dryer is registered by measuring several output variables, i.e. external drum temperature,
product moisture content, mass flow rate.