Preferred Language
Articles
/
jbcd-1747
Evaluation of Osseointegration of Dental Implants Prepared by Piezosurgery (Clinical Study)
...Show More Authors

ABSTRACT Background: Piezosurgery device is a system developed recently to overcome the limitation of the traditional surgical technique in implant site preparation, which use the principle of ultrasonic microvibrations to create precise & selective cut in bone in harmony with the surrounding tissues. The aim of this study was to evaluate the outcomes of implants inserted by ultrasonic implant site preparation protocol (UISP) using piezosurgery device, regarding the survival rate, stability and other related factors, at 16 weeks postoperative follow up period. Materials and Methods: A total of (24) patients, (6) males and (18) females, aged between (19-51) years old, contributed in this study receiving a total of (42) implants, all of these implants bed were prepared by means of special tips mounted in piezosurgery device. For each patient thorough clinical and radiographical preoperative assessment was applied. Implant stability quotient (ISQ) values were measured at baseline, 8 weeks and at 16 weeks. Postoperative clinical and radiographic evaluation was applied for each patient for 16 weeks postoperatively. Results: (24) patients received (42) implants accomplished the follow-up period, After 16 weeks all implants (42) were osseointegrated and the overall implants survival rate was 100% with no failure and no complication was observed. The mean ISQ value at baseline was (74.32±6.42), the mean ISQ value at 8 weeks was (72.62±9.05) and at 16 weeks the mean ISQ (±SD) value was (76.68±7.35) the changes in the mean stability during the healing period showed significant increase in the implant stability (P≤0.05). At the 16th week the number of implants that achieved ISQ≥70 was 35 (83.3%), and 7 implants attained ISQ> 70 (16.7%). Conclusions: high and significant survival rate, significant secondary stability, early positive shifting of the mean ISQ value, no remarkable complications in implants inserted by ultrasonic implant site preparation indicated that piezosurgery is a reliable alternative and safe method used in dental implant osteotomy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of American Science
Morphohistological study of the tongue in local mice species by using special stain
...Show More Authors

Preview PDF
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Study of Reactivity Effect on Reactor Power by Using the Neutronic- Thermohydrolic Coupling
...Show More Authors

The study deals with reactivity insertion linear and non linear and/or Ramp reactivity expressed as a polynomial in time in the presence of two Feedback mechanisms, using the neutronic-thermohydraulic coupling in order to predict the neutron behavior as a function of time in terms of reactor power. Also, a comparative study has been achieved in the case of the presence of the feedback mechanisms. Insertion of Ramp reactivities in terms of polynomial in time to study the behavior of power and reactivity as a function of time in the presence of two feedback mechanisms (fuel and coolant) has been carried out and the results are displayed as plots, and showed this results corresponding with international results. The present study shows t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun May 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Study of Wear Effect on the Unsaturated Resin Reinforced By Rice Husk
...Show More Authors

This study was performed by using the unsaturated polyester resin as matrix to the
composite materials with the rice husk as reinforced materials . The research included study
of wear test on the composite material The results show that the, wear is increased with the
increase of applied load and distance slipping and also with time increase . moreover the
shows that the higher value wear rate( 1.91gm/cm) from the load (20) N and the higher value
wear rate (1.43gm/cm) from the higher distance (4cm) and from the higher time (6min) higher
wear rate (5.33gm/cm).

View Publication Preview PDF
Publication Date
Wed Apr 12 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
the Optical Properties of Electrostatic Design and Study Mirror By using Bimurzaev Technique
...Show More Authors

In this research a computational simulation  has been carried out on the design and properties of the electrostatic mirror and a mathematical expression has been suggested  to represent the axial potential of an electrostatic mirror. The electron beam path using the Bimurzaev  technique had been investigated as mirror trajectory with the aid of Runge – Kutta  method. The spherical and chromatic aberration coefficients of mirror has computed and normalized in terms of the focal length. The choice of the mirror depends on the operational requirements. The Electrode shape of mirror two electrodes has been determined by using package SIMION computer program. Computations have shown that the suggested potentials giv

... Show More
View Publication Preview PDF
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study of the Optical Properties for ZnS Thin Film Irradiated by CO2 Laser
...Show More Authors

In this study ZnS thin film was prepared by using thermal evaporation vacuum technique under the pressure (10-6) Torr on glass substrate at room temperature and annealing at 523 K Samples were irradiated to CO2 laser of power (1 watt) and wave length (10.6) μm at distance 10 cm from the source during (5 sec). The absorbance spectra was recorded by using UV-visible spectrophotometer and used to calculated some of optical properties investigated including their transmittance, reflectance spectra, energy gap, and extinction coefficient. From the result of thin films samples at room temperature and at 523 K, we conclude that the irradiation by laser causes a decrease in the transmittance and increasing in reflection and extinction coeffic

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
The Turkish Journal Of Endocrinology And Metabolism
Cell-free DNA as a Clinical Indicator in Maternal Blood
...Show More Authors

As many expensive and invasive procedures are used for the diagnosis or follow-up of clinical conditions, the measurement of cell-free DNA is a promising, noninvasive method, which considers using blood, follicular fluid, or seminal fluid. This method is used to determine chromosomal abnormalities, genetic disorders, and indicators of some diseases such as polycystic ovary syndrome, pre-eclampsia, and some malignancies. Cell-free DNA, which are DNA fragments outside the nucleus, originates from an apoptotic process. However, to be used as a marker for the previously mentioned diseases is still under investigation. We discuss some aspects of using cell-free DNA measurements as an indicator or marker for pathological conditions.

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Aug 21 2017
Journal Name
Biomedical And Pharmacology Journal
Gene Expression and Clinical Manifestations in Iraqi Patients with Acromegaly
...Show More Authors

Scopus Crossref
Publication Date
Tue May 08 2018
Journal Name
Journal Of Dental Research
Self-Limiting versus Conventional Caries Removal: A Randomized Clinical Trial
...Show More Authors

A single-blind randomized controlled clinical trial in patients with deep caries and symptoms of reversible pulpitis compared outcomes from a self-limiting excavation protocol using chemomechanical Carisolv gel/operating microscope (self-limiting) versus selective removal to leathery dentin using rotary burs (control). This was followed by pulp protection with mineral trioxide aggregate (MTA) and restoration with glass ionomer cement and resin composite, all in a single visit. The pulp sensibility and periapical health of teeth were assessed after 12 mo, in addition to the differences in bacterial tissue concentration postexcavation. Apical radiolucencies were assessed using cone beam computed tomography/periapical radiographs (CBC

... Show More
View Publication
Scopus (36)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Iraqi Journal Of Veterinary Sciences
Incidence of cutaneous and subcutaneous tumors of dogs from Baghdad city: Clinical, cytological and histopathological features
...Show More Authors

The present study was conducted to estimate the incidence, clinical findings, cytological and histopathological characteristics of spontaneously occurring skin neoplasms in dogs. A total of 40 grossly suspected cases of cutaneous and subcutaneous tumors were gathered during the period from July 2016 to August 2018 from male and female dogs in Baghdad city. Dogs with skin neoplasia revealed various clinical signs, and their ages were older than 5 years to 15 years. German shepherd 30% followed by Terrier dogs 25% were more influenced than other breeds. Concerning tumor features, the majority of neoplasms had solitary lesion 70%, regular shapes 65% with black color 55%. The tumors frequently occurred on fore-limbs and abdomen, and 80% of them

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer lens Implantat for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.

Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in  Eye Specialty Private Hospital, Baghdad, Iraq.

Type of the Study: a prospective non randomize intervention study.

Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter

... Show More
View Publication Preview PDF
Crossref