Background: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randomly divided into four groups with 10 samples in each group: Group A instrumentation by WaveOne reciprocating file, Group B instrumentation by TRUShape 3D rotating files, Group C instrumentation by Hyflex CM rotating files and Group D instrumentation by One Shape rotating file. A total volume of 7 ml of sodium hypochlorite was used for irrigation in each sample. Apical patency confirmed and maintained by a size #15 K-File. All canals were instrumented up to a size #25. After completion of endodontic instrumentation, vials were then stored in an incubator for 5 days at 68o C for dryness. Then vials are weighted again, and the pre-weight subtracted from the post-weight, the weight difference resembled the amount of apically extruded debris from the apical foramen during root canal instrumentation. Data obtained were statistically analysed by using ANOVA and LSD tests. Results: The results showed that the Hyflex CM Group (C) has statistical significant lowest apically extruded debris as compared to other groups of this study (P ≤0.05), while the TRUShape Group (B) has statistical significant lowest apically extruded debris as compared to One Shape Group (D) and WaveOne Group (A), while the WaveOne Group (A) showed the highest value of apically extruded debris (p ≤0.01). The result showed that all groups resulted in apical extrusion of debris. Significance: Although all systems caused apical extrusion of debris and irrigant, continuous rotary instrumentation was associated with less extrusion as compared with the use of reciprocating file system.
In this article, new Schiff base ligand LH-prepared Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Hg(II), Pd(II), and Pt(II) materials were analyzed using spectroscopy (1 Metal: 2 LH). The ligand was identified using techniques such as FTIR, UV-vis, 1H-13C-NMR, and mass spectra, and their complexes were identified using CHN microanalysis, UV-vis and FTIR spectral studies, atomic absorption, chloride content, molar conductivity measurements, and magnetic susceptibility. According to the measurements, the ligand was bound to the divalent metal ions as a bidentate through oxygen and nitrogen atoms. The complexes that were created had microbicide activity against two different bacterial species and one type of fungus. DPPH techniques were bei
... Show MoreBackground: Very low birth weight (VLBW) neonates constitute approximately 4–7 percent of all live births and their mortality is very high.
Objective: to find out if there is a relationship between Very Low Birth Weight Neonates and increased neonatal mortality for age 0 to 7 days.
Methods: A retrospective study of VLBW neonates admitted to NICU at Ibn Al- Baladi Pediatrics and Maternity hospital over one year (2012)were studied, The study period was from April till August 2013. Exclusion criteria were: (1) neonates weighing less than 700 g and with gestational age less than 24 weeks (abortion) (2) death in the delivery room (3) neonates weighing more than 1500 g. (4) Postnatal age more than 7 days. The outcome measure was in-hos
The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % we
... Show MoreB aa cc kk gg r oo uu nn dd : Very low birth weight (VLBW) neonates constitute approximately 4–7 percent of all live births and their mortality is very high. O bb j ee cc t i vv ee: to find out if there is a relationship between Very Low Birth Weight Neonates and increased neonatal mortality for age 0 to 7 days. M ee t hh oo dd ss A retrospective study of VLBW neonates admitted to NICU at Ibn Al- Baladi Pediatrics and Maternity hospital over one year (2012)were studied, study period was from April till August 2013. Exclusion criteria were: (1) neonates weighing less than 700 g and with gestational age less than 24 weeks (abortion) (2) death in the delivery room (3) neonates weighing more than 1500 g. (4) Postnatal age more than 7 days.
... Show MoreWearable sensors are a revolutionary tool in agriculture because they collect accurate data on plant environmental conditions that affect plant growth in real-time. Moreover, this technology is crucial in increasing agricultural sustainability and productivity by improving irrigation strategies and water resource management. This review examines the role of wearable sensors in measuring plant water content, leaf and air humidity, stem flow, plant and air temperature, light, and soil moisture sensors. Wearable sensors are designed to monitor various plant physiological parameters in real-time. These data, obtained through wearable sensors, provide information on plant water use and physiology, making our agricultural choices more informed an
... Show MoreThe research aims to design a narrow-band frequency drive amplifier (1.5GHz -1.6GHz), which is used to boost the transmitter amplifier's input signal or amplify the GPS, GlONASS signals at the L1 band.
The Power Amplifier printed circuit board (PCB) prototype was designed using InGaP HBT homogeneous technology transistor and GaAs Heterojunction Bipolar Transistor (HBT) transistor. Two models have been compared; one of the models gave 16dB gain, and the other gave 23dB when using an input power signal (-15dBm). The PCB consumes 2.4W of power and has a physical dimension of 11 x 4 cm.