Preferred Language
Articles
/
jbcd-1733
Comparative Study of The Amount of Apically Extrusion Of Debris During Root Canal Preparation Using Wave Oneâ„¢, Trushape 3Dâ„¢, Hyflexâ„¢ CM and One Shapeâ„¢ Instrumentation Systems (An In Vitro Study)
...Show More Authors

Background: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randomly divided into four groups with 10 samples in each group: Group A instrumentation by WaveOne reciprocating file, Group B instrumentation by TRUShape 3D rotating files, Group C instrumentation by Hyflex CM rotating files and Group D instrumentation by One Shape rotating file. A total volume of 7 ml of sodium hypochlorite was used for irrigation in each sample. Apical patency confirmed and maintained by a size #15 K-File. All canals were instrumented up to a size #25. After completion of endodontic instrumentation, vials were then stored in an incubator for 5 days at 68o C for dryness. Then vials are weighted again, and the pre-weight subtracted from the post-weight, the weight difference resembled the amount of apically extruded debris from the apical foramen during root canal instrumentation. Data obtained were statistically analysed by using ANOVA and LSD tests. Results: The results showed that the Hyflex CM Group (C) has statistical significant lowest apically extruded debris as compared to other groups of this study (P ≤0.05), while the TRUShape Group (B) has statistical significant lowest apically extruded debris as compared to One Shape Group (D) and WaveOne Group (A), while the WaveOne Group (A) showed the highest value of apically extruded debris (p ≤0.01). The result showed that all groups resulted in apical extrusion of debris. Significance: Although all systems caused apical extrusion of debris and irrigant, continuous rotary instrumentation was associated with less extrusion as compared with the use of reciprocating file system.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the cleaning efficiency of the isthmus using different rotary instrumentation techniques (In vitro study)
...Show More Authors

Background: The aims of the study were to evaluate the unclean/clean root canal surface areas with a histopathological cross section view of the root canal and the isthmus and to evaluate the efficiency of instrumentation to the isthmus using different rotary instrumentation techniques. Materials and Methods:The mesial roots of thirty human mandibular molars were divided into six groups, each group was composed of five roots (10 root canals)which prepared and irrigated as: Group one A: Protaper system to size F2 and hypodermic syringe, Group one B: Protaper system to size F2 and endoactivator system, Group two A:Wave One small then primary file and hypodermic syringe, Group two B:Wave One small then primary file and endoactivator system, Gr

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative study of retention of fiber-reinforced post at middle and cervical one thirds of root canal cemented by polycarboxylate and zinc phosphate cements measured at different storage times
...Show More Authors

Background: The purpose of this study was to compare regional bond strength at middle and cervical thirds of the root canal among glass fiber-reinforced composite (FRC) endodontic posts cemented with different cements, using the push-out test to compare the performance (retention) of two types of luting cements; polycarboxylate cement and Zinc phosphate cement used to cement translucent fiber post and to compare the result of the push-out test at different storage times;1 week ,1month and 2 months. Materials and methods: Ninety caries-free, recently extracted single-rooted human teeth with straight root canals was used in this study, The root canals were endodontically instrumented at a working length of 0.5 mm from the apex by m

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Influence of Different Fabrication Techniques and Preparation Designs on the Marginal Adaptation of Ceramic Veneers (An In vitro Comparative Study)
...Show More Authors

Background: Ceramic veneers represent the treatment of choice in minimally invasive esthetic dentistry; one of the critical factors in their long term success is marginal adaptation. The aim of the present study is to evaluate the marginal gap of ceramic veneers by using two different fabrication techniques and two different designs of preparation. Material and methods: A typodont maxillary central incisor used in the preparation from which metal dies were fabricated, which were in turn used to make forty stone dies. The dies divided into four experimental groups, each group had ten samples: A1: prepared with butt-joint incisal reduction and restored with IPS e.max CAD, A2: prepared with overlapped incisal reduction and restored with IPS e.

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 20 2020
Journal Name
International Medical Journal
Cleaning efficacy and instrumentation time using rotary file system in primary molars (comparative study)
...Show More Authors

ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to a

... Show More
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Microleakage of Pit and Fissure Sealants after Using Different Occlusal Surface Preparation Techniques: An In Vitro Study
...Show More Authors

Background: The marginal seal is essential for sealant success because penetration of bacteria under the sealant might allow caries onset or progression. The aim of the present study was to estimate and compare the microleakage of pit and fissure sealant after various methods of occlusal surface preparation. Materials and methods: Thirty non-carious premolars extracted for orthodontic reasons were equally divided into three groups. In group one, occlusal fissures were opened with round carbide bur, in group two, occlusal surfaces of the teeth were cleaned with a dry pointed bristle brush and samples of group three were cleaned with a slurry of fine flour of pumice in water using rubber cup. Then fissures of all teeth were etched using 35% p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Push out bond strength of different obturation systems (An in vitro study)
...Show More Authors

Background: The bond strength of the root canal sealers to dentin seems to be a very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate the shear bond strength of four different obturation systems using push-out test. Materials and methods: Forty straight palatal roots of the maxillary first molars teeth were used in this study, these roots were instrumented using crown down technique and ProTaper system, instrumentation were done with copious irrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilled water, roots were randomly divided into four groups according to the obturation system (ten teeth for each g

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An in-vitro scan electron microscope comparative study of dentine-Biodentine interface
...Show More Authors

Background: Restoration of the gingival margin of Class II cavities with composite resin continues to be problematic, especially where no enamel exists for bonding to the gingival margin. The aim of study is to evaluate the marginal leakage at enamel and cementum margin of class II MOD cavities using amalgam restoration and modern composite restorations Filtek™ P90, Filtek™ Z250 XT (Nano Hybrid Universal Restorative) and SDR bulk fill with different restoratives techniques. Materials and method: Eighty sound maxillary first premolar teeth were collected and divided into two main groups, enamel group and cementum group (40 teeth) for each group. The enamel group was prepared with standardized Class II MOD cavity with gingival margin (1 m

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Brazilian Dental Science
Antimicrobial activity of Er,Cr:YSGG and Ultrasonic on E. faecalis biofilm in the mesial root canal systems of lower molars
...Show More Authors

Scopus (1)
Scopus
Publication Date
Tue Mar 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of fracture strength of endodontically treated teeth restored by milled zirconia post and core with different post and core systems (An in vitro comparative study)
...Show More Authors

Background: Restoration of root canal treated teeth with a permanent restoration affect in the success of endodontically treated teeth. This in vitro study was performed to evaluate and compare the fracture strength of endodontically treated teeth restored by using custom made zirconium posts and cores, prefabricated carbon fiber, glass fiber and zirconium ceramic posts. Materials and method: Forty intact human mandibular second premolars were collected for this study and were divided into five groups. Each group contains 8 specimens: Group1: Teeth restored with Carbon Fiber Posts; Group2: Teeth restored with Glass Fiber Posts; Group3: Teeth restored with Zirconium Ceramic prefabricated Posts; Group4: Teeth restored with Zirconium Posts

... Show More
View Publication Preview PDF