Preferred Language
Articles
/
jbcd-169
Postoperative assessment of dental implants by using multi-slice computed tomography
...Show More Authors

Background: Implantology is a fast growing area in dentistry. One of the most common issues encountered in dental implantation procedures is the lack of adequate preoperative planning. Conventional radiography may not be able to assess the true regional three-dimensional anatomical presentation. Multi Slice Computed Tomography provides data in 3-dimentional format offering information on craniofacial anatomy for diagnosis; this technology enables the virtual placement of implant in a 3-Dimensional model of the patient jaw (dental planning). Patients, Material and Methods: The sample consisted of (72) Iraqi patients indicated for dental implant (34 male and 38 female), age range between (20-70) years old. They were examined during a time period started from December 2012 to April 2013. All the patients who subjected to implant treatment depending on the pre-operative panoramic radiograph were referred Al-Kharkh General hospital, spiral CT scan Department, for postsurgical assessment evaluate the angulation of fixture in relation to the angulation of bone in coronal and sagittal sections by using Multi-Detector Computed Tomography. Results: The present study showed that the angulation of implant affected by age, sector, and tooth position in the same jaw, and not affected by gender. Conclusion: Multi-Slice Computed Tomography provides a great understanding about bone angulation, it necessary as a diagnostic tool for treatment planning pre and post-operatively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Periodontal & Implant Science
Bio-hybrid dental implants prepared using stem cells with β-TCP-coated titanium and zirconia
...Show More Authors

Purpose This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 o

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of certain radiomorphometric facial indices in different facial types of Iraqi adults using Cone Beam Computed Tomography
...Show More Authors

Background: The human face has its special characteristics. It may be categorized into essentially three kinds in horizontal and vertical directions: short or brachyfacial, medium or mesofacial and long or dolichofacial. The aim of this study was to describe several orofacial indices and proportions of adults, according to gender in Iraqi subjects by using cone beam computed tomography . materials and methods: This prospective study included 100 Iraqi patients (males and females) ranging from 20 to 40 years. All subjects attended the Oral and Maxillofacial Radiology Department of Health Specialist Center for Dentistry in AL Sadr city in Baghdad taking cone beam computed tomography scan for different diagnostic purposes from October 2016 to

... Show More
View Publication
Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative evaluation of the radiographic density of GuttaFlow® 2 in different obturation techniques using Spiral Computed Tomography
...Show More Authors

Background: Ideal root canal obturation depends on many factors; one of them is good sealing of root canal without pores. The aim of this study was to determine the radiographic density of GuttaFlow® 2 with different obturation techniques using spiral computed tomography. Materials and Methods: Forty palatal roots of permanent maxillary first molar were used in this study. Following working length determination, root canal was prepared using rotary PROTAPER universal system. They were randomly divided into four groups of 10 roots each, the groups are Conventional lateral condensation with Apexit Plus sealer, Conventional lateral condensation with GuttaFlow® 2 as a sealer, Soft Core Regular with GuttaFlow® 2 as a sealer and singl

... Show More
View Publication
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Engineering
Agile manufacturing assessment model using multi-grade evaluation
...Show More Authors

In unpredicted industrial environment, being able to adapt quickly and effectively to the changing is key in gaining a competitive advantage in the global market. Agile manufacturing evolves new ways of running factories to react quickly and effectively to changing markets, driven by customized requirement. Agility in manufacturing can be successfully achieved via integration of information system, people, technologies, and business processes. This article presents the conceptual model of agility in three dimensions named: driving factor, enabling technologies and evaluation of agility in manufacturing system. The conceptual model was developed based on a review of the literature. Then, the paper demonstrates the agility

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Mar 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 27 2012
Journal Name
Journal Of Prosthodontics
A Three-Dimensional Finite Element Analysis for Overdenture Attachments Supported by Teeth and/or Mini Dental Implants
...Show More Authors

View Publication
Crossref (14)
Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Postoperative Follow-up for Patients with Recurrent Kidney Stone
...Show More Authors

Abstract Kidney stones are one of the most common and most painful medical problems known (1). Nurses assess and monitor patients through diagnosis and treatment and teach patients how to avoid recurrence of stones (2). A descriptive study was conducted on 150 patients diagnosed with recurrent kidney stones, who were attending the out patients consultation urology disease clinics at surgical specialties, Al-Kadhimia, Al-Yarmook, and Al-Karama Teaching Hospital and Extracorporeal shock wave lithotripsy (ESWL) departments for the period from the 1st of Feb. 2002 through to the end of May 2004. The aim of

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 18 2023
Journal Name
Journal Of Research In Medical And Dental Science
Morphologic Evaluation of the Permanent Mandibular First Molar within an Iraqi Population Using Cone Beam Computed Tomography (Retrospective Study)
...Show More Authors

Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Revista Española De Cirugía Oral Y Maxilofacial
The correlation of alveolar trabecular bone microstructure with bone density measured by cone-beam computed tomography (CBCT) and implant stability
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Mar 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Platelet-Rich Plasma on Osseointegration Period of Dental Implants
...Show More Authors

Background: The preparation of Platelet-rich plasma (PRP) is minimally invasive way, simple, low cost to obtain natural autologous growth factors and is now being widely used in different fields of medicine for its ability to increase the regeneration potential of tissue. The aim of this study was to investigate the effect of local application of autologous PRP gel on acceleration rate of osseointegration period by clinical assessment accomplished by determining the changes in implant stability during 3 months healing period using resonance frequency analysis (RFA). Materials and methods: A total of 28 dental implants were inserted in edentulous maxillae or mandibles of 13 patients using a split mouth design, i.e. each patient was received

... Show More
View Publication Preview PDF