Background: Restoration of root canal treated teeth with a permanent restoration affect in the success of endodontically treated teeth. This in vitro study was performed to evaluate and compare the fracture strength of endodontically treated teeth restored by using custom made zirconium posts and cores, prefabricated carbon fiber, glass fiber and zirconium ceramic posts. Materials and method: Forty intact human mandibular second premolars were collected for this study and were divided into five groups. Each group contains 8 specimens: Group1: Teeth restored with Carbon Fiber Posts; Group2: Teeth restored with Glass Fiber Posts; Group3: Teeth restored with Zirconium Ceramic prefabricated Posts; Group4: Teeth restored with Zirconium Posts and Cores (copy milling); Group5: (Control Group).For groups 1, 2, 3, and 4; crowns were removed horizontally at the level of cement-enamel junction. Endodontic therapy was then done for all specimens in these groups using step-back technique.These specimens received standardized posts preparation (10mm depth), and then mounted in acrylic resin blocks. Panavia F 2.0 dual cure resin cement was used for cementation. The core build up was done with composite (Filtek P60). The specimens were then stored in saline and were subjected to compressive loads parallel to their long axes using universal testing machine (WP 300) until failure. Results: Data obtained were analyzed by one-way analysis of varianceand student t-test. The results showed that zirconium posts and cores possessed the highest significant differences followed by glass fiber posts, carbon fiber posts, and prefabricated ceramic zirconium posts. There were no significant differences between glass fiber, carbon fiber, and control group. The specimens were examined to determine the root fracture patterns and locations. Conclusion: In the present study the fiber post treated teeth showed significantly more desirable fracture patterns compared to those restored with zircon posts.
Abstract:
This research aims to identify the actual reality of the supply chain processes applied in the Noor Al-Kafeel Food Products Company, which was chosen as a research sample by measuring the application and documentation gap. The current research relies on the case study method to reach the desired results, and the seven-scale scale was relied on to identify the reality of the supply chain operations applied in the researched company and the use of quantitative and qualitative methods in data collection and analysis, as quantitative methods such as the arithmetic mean were used weighted, percentage measurement, and g
... Show MoreThis paper is concerned with introducing and studying the M-space by using the mixed degree systems which are the core concept in this paper. The necessary and sufficient condition for the equivalence of two reflexive M-spaces is super imposed. In addition, the m-derived graphs, m-open graphs, m-closed graphs, m-interior operators, m-closure operators and M-subspace are introduced. From an M-space, a unique supratopological space is introduced. Furthermore, the m-continuous (m-open and m-closed) functions are defined and the fundamental theorem of the m-continuity is provided. Finally, the m-homeomorphism is defined and some of its properties are investigated.
In this study, a mathematical model for the kinetics of solute transport in liquid membrane systems (LMSs) has been formulated. This model merged the mechanisms of consecutive and reversible processes with a “semi-derived” diffusion expression, resulting in equations that describe solute concentrations in the three sections (donor, acceptor and membrane). These equations have been refined into linear forms, which are satisfying in the special conditions for simplification obtaining the important kinetic constants of the process experimentally.
In this paper, a sufficient condition for stability of a system of nonlinear multi-fractional order differential equations on a finite time interval with an illustrative example, has been presented to demonstrate our result. Also, an idea to extend our result on such system on an infinite time interval is suggested.
Urinary tract infection is a bacterial infection that often affects the bladder and thus the urinary system. E. coli is one of the leading uropathogenic bacteria that cause urinary tract infections. Uropathogenic E. coli is highly effective and successful in causing urinary tract infections through biofilm formation and urothelial cell invasion mechanisms. Other organisms that cause urinary tract infections include members of the Enterobacteriaceae family, streptococci and staphylococci species and perch. In addition, K.penumoniae is another important gram-negative bacterium that causes urinary tract infections. With the PCR technique, unseen bacterial species can be detected using standard clinical microbiology methods. In this study, the
... Show More4 Blood Res 2018;53:314-319. Received on August 11, 2018 Revised on August 30, 2018 Accepted on August 30, 2018 Background Iron overload is a risk factor affecting all patients with thalassemia intermedia (TI). We aimed to determine whether there is a relationship of serum ferritin (SF) and alanine ami- notransferase (ALT) with liver iron concentration (LIC) determined by R2 magnetic reso- nance imaging (R2-MRI), to estimate the most relevant degree of iron overload and best time to chelate in patients with TI. Methods In this cross-sectional study, 119 patients with TI (mean age years) were randomly se- lected and compared with 120 patients who had a diagnosis of thalassemia major (TM). Correlations of LIC, as determined by R2-MRI, with SF
... Show MoreThe present work describes numerical and experimental investigation of the heat transfer characteristics in a plate-fin, having built-in piezoelectric actuator mounted on the base plate (substrate). The geometrical configuration considered in the present work is representative of a single element of the plate-fin and triple fins. Air is taken as the working fluid. A performance data for a single rectangular fin and triple fins are provided for different frequency levels (5, 30 and
50HZ) , different input power (5,10,20,30,40 and 50W) and different inlet velocity (0.5, 1, 2, 3, 4, 5 and 6m/s) for the single rectangular fin and triple fins with and without oscillation. The investigation was also performed with different geometrical fin
This field experiment was conducted at Research Station B, Department of Horticulture and Landscape Engineering, College of Agricultural Engineering Sciences, University of Baghdad, Jadiriyah during the fall season of 2019-2020 to evaluate the effect of cultivation dates and soil fertilization source on the growth, yield and quality of broccoli. A split plot design within the RCBD design with three replicates was applied as the Max F1 hybrid broccoli seedlings were transferred to the field at two dates 25, Sep. 2019 and 15, Oct. 2019, which were symbolized as A and B, respectively, and occupied at the main plot. After two weeks of cultivation, the soil fertilizers were applied three times during the season in 20 days between each applicati
... Show More