Background: Pit and fissure sealant have been considered an outstanding adjunct to oral health care in the decrease of occlusal caries onset and low progression. The aims of this in vitro study were to evaluate the marginal microleakage of three different types of fissure sealants (SDI, Tg and tetric N-flow) by time interval, one day and 45 days, in the presence or absence of bonding agent among maxillary and mandibular teeth. Materials and methods: Seventy two sound human maxillary and mandibular first premolar teeth were collected which were free from obvious carious lesions. The teeth were randomly divided into two main equal groups, group (1) and group (2), each group consists of (36) teeth involving equal numbers of maxillary and mandibular teeth. The first group incubated for one day, the second incubated for (45) days. Each group divided into two subgroup; one of them treated with bonding agent while the other without. Then each subgroup was treated with three different materials which were; Tg sealant (without fluoride) group (A), SDI sealant (containing fluoride) group (B) and Tetric N-flow (flowable composite) group (C). Each one consist of six teeth involving three maxillary and three mandibular. Then dye penetration tested by using methylene blue dye, then the teeth cleaned and sectioned by sectioning device and tested under microscope. Results, the results had shown that, group (C+) in both incubation periods have no microleakage (score 0), but there was an opposite effect when using bonding agent with sealant materials not containing filler particles that showed a significant increase in the microleakage rate as shown in groups (A+ and B+). The opposite effect was seen also when used sealant materials containing filler particles but without bonding agent that seen in group (C) during both incubation periods that showed significant increasing in microleakage rate. While the effect of fluoride was very clear in decreasing significantly the microleakage rate after (45) days of incubation in both groups that treated with and without bonding agent (groups B and B+). Concerning the anatomical variation, there were no significant changes in most groups regarding the microleakage rate. Conclusions: Results had shown that the microleakage can be prevented by using of flowable composite containing nanofillers that treated with bonding agent after etching of enamel with 35% phosphoric acid gel.
Over the last 40 years, rate of cesarean delivery has risen from less than10% to over 30% around the world, and almost simultaneously a 10-foldraise in the incidence of placenta accrete spectrum. Fine coordinationamong vascular endothelial growth factor, soluble fms-like tyrosine kinase1 and placental growth factor is important for normal placentaldevelopment and trophoblast invasion. To measure and compare the levelsof circulating vascular endothelial growth factor, placental growth factorand soluble fms-like tyrosine kinase 1 in pregnant women with placentaaccreta to a control group. A case control study which involved one hundredpregnant females were recruited from the Obstetric ward in BaghdadTeaching Hospital who were pregnant with 28
... Show MoreWet granulation method was used instead of conventional pan coating or fluidized –bed coating technique to prepare enteric-coated diclofenac sodium granules, using ethanolic solution of EudragitTM L100 as coating, binding and granulating agent .Addition of PEG400 or di-n-butyl phthalate as a plasticizer was found to improve the enteric property of the coat.
Part of the resulted granules was filled in hard gelatin capsules (size 0), while the other part was compressed into tablets with and without disintegrant.
The release profile of these two dosage forms in 0.1N HCl (pH 1.2)for 2 hours, and in phosphate buffer (pH 6.8) for 45 minutes as well as the release kinetic were compared with that of the en
... Show MoreThe effective insulation design of the stress grading (SG) system in form-wound stator coils is essential for preventing partial discharges and excessive heat generation under pulse-width modulation excitation. This paper proposes a method to find the optimal insulation design of the SG system aimed at reducing the dielectric and thermal stresses in the machine coil. The non-uniform transmission line model is used to predict the voltage propagation along the overhang, SG, and slot regions considering the variation in the physical properties of the insulation layers. The machine coil parameters for different insulation materials are calculated by using the finite element method. Two optimization algorithms, fmincon and particle swarm optimiz
... Show MoreBackground: Tumor necrosis factor-alpha (TNF-α) and interleukins play important roles in the pathogenesis of rheumatoid arthritis (RA). Genetic research has been employed to find many of the missing connections between genetic risk variations and causal genetic components. Objective: The goal of this study is to look at the genetic variations of TNF-α and interleukins in Iraqi RA patients and see how they relate to disease severity or response to biological therapy. Method: Using specific keywords, the authors conducted a systematic and comprehensive search to identify relevant Iraqi studies examining the genetic variations of TNF-α and interleukins in Iraqi RA patients and how they relate to disease severity or response to biolo
... Show MoreBackground: The present study was carried out to compare shear bond strength of sapphire bracket bonded to zirconium surface after using different methods of surface conditioning and assessment of the adhesive remnant index. Materials and methods: The sample composed of 40 zirconium specimens divided into four groups; the first group was the control, the second group was conditioned by sandblast with aluminum oxide particle 50 μm, the third and fourth group was treated by (Nd: YAG) laser (1064nm)(0.888 Watt for 5 seconds) for the 1st laser group and (0.444 Watt for 10 seconds) for the 2nd laser group. All samples were coated by z-prime plus primer. A central incisor sapphire bracket was bonded to all samples with light cure adhesive res
... Show MoreBackground: The marginal adaptation has a key role in the success and longevity of the fixed dental restoration, which is affected by the impression and the fabrication techniques .The objective of this in vitro study was to evaluate and compare the marginal fitness of lithium disilicate crowns using two different digital impression techniques (direct and indirect techniques) and two different fabrication techniques (CAD/CAM and Press techniques). Materials and Methods: Thirty two sound upper first premolar teeth of comparable size extracted for orthodontic reason were selected in this study .Standardized preparation of all teeth samples were carried out with modified dental surveyor to receive all ceramic crown restoration with 1 mm deep
... Show MoreBackground: This in vitro study was carried out to evaluate the effect of various endodontic irrigants (sodium hypochlorite, ethylene diaminetetracetic acid and normal saline) on sealing ability of (Biodentine, mineral trioxide aggregate, and amalgam) used to repair furcal perforations. Material and methods: One hundred and twenty extracted human molars with divergent roots were used in this study. A standard root canal access cavity was prepared in each tooth and furcal perforation was made and was standardized by using k file size 100 instrument to get a perforation of (1.32mm) in diameter .The teeth were randomly divided in to three groups of 40 teeth according to the type of material used to repair the perforations (Group A: The furcal
... Show MoreBackground: Health professionals have a crucial role in promotion, support and management of breastfeeding. To be effective in this effort, the clinician should focus on the issue from the preconception stage through pregnancy and delivery, and continue in subsequent infant care. Aim of the study: to assess the effectiveness of the UNICEF/WHO 40-hour of breast feeding training through the assess breastfeeding knowledge and attitudes of the health profession staff before and after training course.
Using sodium4-((4,5-diphenyl-imidazol-2-yl)diazenyl)-3-hydroxynaphthalene-1-sulfonate (SDPIHN) as a chromogenic reagent in presence of non-ionic surfactant (Triton x-100) to estimate the chromium(III) ion if the wavelength of this reagent 463 nm to form a dark greenish-brown complex in wavelength 586 nm at pH=10,the complex was stable for longer than 24 hours. Beer's low, molar absorptivity 0.244×104L.mol-1.cm-1, and Sandal's sensitivity 0.021 µg/cm2 are all observed in the concentration range 1-11 µg/mL. The limits of detection (LOD) and limit of quantification (LOQ), respectively, were 0.117 µg/mL and 0.385µg/mL. (mole ratio technique, job's method) were employed to
... Show More