Background: Pit and fissure sealant have been considered an outstanding adjunct to oral health care in the decrease of occlusal caries onset and low progression. The aims of this in vitro study were to evaluate the marginal microleakage of three different types of fissure sealants (SDI, Tg and tetric N-flow) by time interval, one day and 45 days, in the presence or absence of bonding agent among maxillary and mandibular teeth. Materials and methods: Seventy two sound human maxillary and mandibular first premolar teeth were collected which were free from obvious carious lesions. The teeth were randomly divided into two main equal groups, group (1) and group (2), each group consists of (36) teeth involving equal numbers of maxillary and mandibular teeth. The first group incubated for one day, the second incubated for (45) days. Each group divided into two subgroup; one of them treated with bonding agent while the other without. Then each subgroup was treated with three different materials which were; Tg sealant (without fluoride) group (A), SDI sealant (containing fluoride) group (B) and Tetric N-flow (flowable composite) group (C). Each one consist of six teeth involving three maxillary and three mandibular. Then dye penetration tested by using methylene blue dye, then the teeth cleaned and sectioned by sectioning device and tested under microscope. Results, the results had shown that, group (C+) in both incubation periods have no microleakage (score 0), but there was an opposite effect when using bonding agent with sealant materials not containing filler particles that showed a significant increase in the microleakage rate as shown in groups (A+ and B+). The opposite effect was seen also when used sealant materials containing filler particles but without bonding agent that seen in group (C) during both incubation periods that showed significant increasing in microleakage rate. While the effect of fluoride was very clear in decreasing significantly the microleakage rate after (45) days of incubation in both groups that treated with and without bonding agent (groups B and B+). Concerning the anatomical variation, there were no significant changes in most groups regarding the microleakage rate. Conclusions: Results had shown that the microleakage can be prevented by using of flowable composite containing nanofillers that treated with bonding agent after etching of enamel with 35% phosphoric acid gel.
Background: The aims of the study were to evaluate the unclean/clean root canal surface areas with a histopathological cross section view of the root canal and the isthmus and to evaluate the efficiency of instrumentation to the isthmus using different rotary instrumentation techniques. Materials and Methods:The mesial roots of thirty human mandibular molars were divided into six groups, each group was composed of five roots (10 root canals)which prepared and irrigated as: Group one A: Protaper system to size F2 and hypodermic syringe, Group one B: Protaper system to size F2 and endoactivator system, Group two A:Wave One small then primary file and hypodermic syringe, Group two B:Wave One small then primary file and endoactivator system, Gr
... Show MoreChlopheniramine maleate ( CPM ) , is one of the H- receptor antagonist , widely used in allergic diseases ,like skin rash and pruritis .CPM 3%w/w was successfully loaded in 2%w/w sodium alginate (SA) as a gel base , and to be considered as a selected formula .It was found that the diffusion of CPM through the skin of albino rat was increased as the concentration of CPM increased from 2 %w/w sodium alginate , More
... Show MoreThe goals of endodontic preparation were to shape and clean the space of the root canal and remove microorganisms, affected dentin and pulp, the apical foramen and the canal curve should be protected from being transported during endodontic canal preparation. The aim of this study was to evaluate the curve straightening of curved root canals and apical transportation after preparation with four rotary systems. Forty mesial roots of the lower 1st molars teeth only the mesiobuccal canals were used, these roots were immersed into cold clear acrylic , the teeth roots divided into four groups according to rotary system used for preparation of the canals (ten roots for each group):. group I: ProTaper Next rotary system, group II: IRaCe Plus rotar
... Show MoreOsteoarthritis is the most prevalent arthritic disease and a leading cause of disability. The pathogenesis of osteoarthritis involves multiple etiologies, including variable degree of synovial inflammation. Metformin and pioglitazone could potentially reduce the levels and activity of inflammatory mediators. This may consider as a new therapeutic approach added to the current used drugs in an attempt to decrease the pain, inflammation, and improve daily activity and quality of life in patients with knee osteoarthritis.
This study designed to evaluate the clinical utility of using metformin or pioglitazone as anti-inflammatory agents in combination with non-steroidal anti-inflammatory drugs (NSAID) of selective type of cyclooxygen
... Show MoreEfficacy of Varnishes with: Bioactive Glass, Recaldent Technology and Silver Diamine Fluoride in Comparison with Sodium Fluoride on Tooth Surface Micro-hardness (an In Vitro Study)
Background: Debonding orthodontic brackets and removal of residual bonding material from the enamel surface include critical steps that may cause enamel damage. The aim of the present study was to evaluate and compare the site of bond failure and enamel surface damage after debonding of three types of esthetic brackets (composite, ceramic, sapphire) bonded with light cure composite and resin-modified glass ionomer adhesive. Materials and methods: Seventy two maxillary premolars teeth were divided into three groups each group consisted of 24 teeth according to the type of brackets. Each group was subdivided into two subgroups (12 teeth for each) according to the bonding material that was used. After 7 days of bonding procedure, the brackets
... Show MoreEquilibrium and rate of mixing of free flowing solid materials are found using gas fluidized bed. The solid materials were sand (size 0.7 mm), sugar (size0.7 mm) and 15% cast iron used as a tracer. The fluidizing gas was air with velocity ranged from 0.45-0.65 m/s while the mixing time was up to 10 minutes. The mixing index for each experiment was calculated by averaging the results of 10 samples taken from different radial and axial positions in fluidized QVF column 150 mm ID and 900 mm height.
The experimental results were used in solving a mathematical model of mixing rate and mixing index at an equilibrium proposed by Rose. The results show that mixing index increases with inc
... Show MoreItraconazole (ITZ) is an antifungal drug (BCSII) used for the treatment of local and systemic fungal infections. Furthermore, ITZ used as an antifungal prophylaxis for immunocompromised patients.
The objective of the study is to overcome the two problems of low and pH dependent solubility of ITZ by its preparation as floating microparticles.
Firstly, pH-dependent floating microparticles were prepared using oil in water solvent evaporation method, from which the best one (F7) selected as a best pH-dependent formula with composition of ITZ (200mg),EC (800mg), HPMC 15cps (200mg) and safflower oil (2ml) .Then, F7 was compared with the selected Relatively pH-independent ITZ floating microparticles formula wit
... Show MoreSelexipag is an orally selective long-acting prostacyclin receptor agonist, which indicated for the treatment of pulmonary arterial hypertension. It is practically insoluble in water ( class II, according to BCS). This work aims to prepare and optimized Selexipag nanosuspensions to achieve an enhancement in the in vitro dissolution rate. The solvent antisolvent precipitation method was used for the production of nanosuspension, and the effect of formulation parameters (stabilizer type, drug: stabilizer ratio, and use of co-stabilizer) and process parameter (stirring speed) on the particle size and polydispersity index were studied. SLPNS prepared with Soluplus® as amain stabilizer (F15) showed the smallest particle size 47nm wi
... Show More