Preferred Language
Articles
/
jbcd-155
Force decay of orthodontic elastomeric chains by using three different mechanisms simulating canine retraction
...Show More Authors

Background: The ideal force-delivery system must: provide optimal tooth moving forces that elicit the desired effects, be comfortable and hygienic for the patient, require minimal operator manipulation and patient cooperation and provide rapid tooth movement with minimal mobility during orthodontic therapy, the elastomeric chains have the greatest potential to fulfill these requirements. Materials and Methods: This in vitro study was designed to determine the effect of three different mechanisms for canine retraction : (6-3 , 6-5-3 and chain loop ) on the load relaxation behavior of three types of elastomeric chains : (maximum clear , maximum silver and extreme silver) from the same company (Ortho Technology company) with two different brand configurations: closed loop and open (short filament) chains under effect of time at (zero time, 24hr., 7, 14 , 21 and 28 days) in artificial saliva. Results: Statistical analysis showed that there was a highly significant difference in the mean percentage force decay for the three different mechanisms (P? 0.001).For all the three types, the 6-3 mechanism had the smallest mean percentage force decay. There was a highly significant difference in the mean percentage force decay for the different types (P? 0.001). For all three mechanisms, extreme silver elastomeric chains had the smallest percentage force decay while maximum silver elastomeric chains had the highest percentage force decay. Conclusion: This study illustrated that for all the three types of elastomeric chains, the (6-3) mechanism had the smallest mean percentage force decay. This finding suggests that it may be most efficient to retract a canine utilizing elastomeric chain directly from the molar hook to the canine bracket. The chain loop mechanism may not be indicated for space closure in vivo due to the excessive physiological force values involved with this mechanism.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
European Journal Of General Medicine
The Value of Longitudinal Strain versus Coronary Angiography in Detection of Coronary Artery Disease
...Show More Authors

Aims: The aim of this study was to evaluate the value and accuracy of longitudinal strain in detection of coronary artery disease compared to coronary angiography. Results: The left ventricular longitudinal strain-speckle tracking showed evidence of stenosis of left anterior descending artery, circumflex artery and right coronary artery in (86.1%), (76.4%), and (84.7%) respectively. For the stenosis in left anterior descending artery, the current study showed that the longitudinal strain was a good predictor for presence of significant stenosis with a sensitivity of (93.8%), specificity (75%) and accuracy (91.7%) compared with coronary angiography. For the stenosis in right coronary artery, the left ventricular longitudinal strain had

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Wed May 27 2015
Journal Name
Diyala Journal For Pure Science
Synthesis And Characterization Of Some New Metals Complexes Of [N-(3-acetylphenylcarbamothioyl)-4-methoxybenzamide]
...Show More Authors

A new ligand [N-(3-acetylphenylcarbamothioyl)-4-methoxybenzamide](MAA) was synthesized by reaction of 4-methoxybenzoylisothiocyanate with 3-aminoacetophenone,The ligand was characterized by elemental microanalysis C.H.N.S, FT-IR, UV-Vis and 1H,13CNMR spectra, some transition metals complexes of this ligand were prepared and characterized by FT-IR, UV-Vis spectra, conductivity measurements, magnetic susceptibility and atomic absorption, From obtained results the molecular formula of all prepared complexes were [M(MAA)2(H2O)2]Cl2 (M+2 =Mn, Co, Ni, Cu, Zn, Cd and Hg),the proposed geometrical structure for all complexes were octahedral

Publication Date
Mon Sep 30 2019
Journal Name
Engineering Journal
Effects of Water Table Level on Slope Stability and Construction Cost of Highway Embankment
...Show More Authors

Highway embankments stability during its service period represents an important factor for the safety of highway users and vehicles. Consequently, the cost of construction of these embankments should be adequate to maintain the safety and durability during this period through proper estimation of the loading on asphalt pavement, slope stability, horizontal and vertical deformation, etc. Slope stability of the embankment mainly depends on the shear strength of the soil layers materials; this shear strength is affected by the water table level through the contribution of the capillary water. Negative pore water pressure above the water table level evolves matric suction in the unsaturated zone above water table; this matric suction increases

... Show More
Crossref (8)
Crossref
Publication Date
Wed Jun 26 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis of Acetylenic Derivatives of a Substituted 1, 3, 4-Thiadiazole as Antibacterial Agents
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Apr 28 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
COMPARISON OF TWO TYPES OF SENSORS AND THEIR EFFECT ON SPRAY QUALITY PEAR TREES
...Show More Authors

This study was aimed to reduce the amount of the sprayed solution lost during trees spraying.  At the same time, the concentration of the sprayed solution on the target (tree or bush) must be ensured and to find the best combination of treatments. Two factors controls the spraying process: (i) spraying speed (1.2 km/h, 2.4 km/h, 3.6 km/h), and (ii) the type of sensor. The test results showed a significant loss reduction percentage. It reached (6.05%, 5.39% and 2.05%) at the speed (1.2 km/h, 2.4 km/h, 3.6 km/h), respectively. It was noticed that when the speed becomes higher the loss becomes less accordingly. The interaction between the 3.6 km/h speed and the type of Ultrasonic sensor led to a decrease in the percentage of the spray

... Show More
Scopus Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Study the Effect of PH Variation on the Particle Size of Sio2 Thin Films
...Show More Authors

In this paper, SiO2 nanoparticles thin films were synthesised at different PH values of solution by sol gel method at fixed temperature (25oC) and molar ratio (R =H2O/precursor) of (Tetra Ethyl Ortho Silicate) TEOS as precursor at (R=1). The structure and optical properties of the thin films have been investigated. All thin films were tested by using X-RAY diffraction. All X-RAY spectrum can be indexed as monoclinic structure with strong crystalline (110) plane. The morphological properties of the prepared films were studied by SEM. The results indicate that all films are in nano scale and the particle size around (19-62) nm .The size of silica particles increases with increasing PH value of solution where both the rate of hydrolysis and

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
EFFECT OF COOLING RATE ON MECHANICAL PROPERTIES OF EUTECTIC AND HYPOEUTECTIC Al-Si ALLOYS
...Show More Authors

In this research the effect of cooling rate and mold type on mechanical properties of the eutectic
and hypoeutectic (Al-Si) alloys has been studied. The alloys used in this research work were (Al- 12.6%Si
alloy) and (Al- 7%Si alloy).The two alloys have been melted and poured in two types of molds with
different cooling rates. One of them was a sand mold and the other was metal mold. Mechanical tests
(hardness, tensile test and impact test) were carried out on the specimens. Also the metallographic
examination was performed.
It has been found that the values of hardness for the alloys(Al-12.6%Si and Al-7%Si) which poured in
metal mold is greater than the values of hardness for the same alloy when it poured in a heated

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Effect of Dam Height on The Stability of Earth Dam (Case Study: Karolinka Dam)
...Show More Authors

The Karolinka earth-fill dam was constructed between 1977 and 1984 on the Stanovnice river above the town of Karolinka in the region of Vsetínsko in Czech Republic. Because of leakage on the downstream dam face due to technological indiscipline when filling dam layers during the dam construction stage, there were some steps to improve state dam safety. The final rehabilitation is to construct the diaphragm walls from self-hardening cement-bentonite suspension along the length of the dam. In addition to connecting the gallery and abutment (2 × 25 m long) by using jet piles. The article presents numerical modeling of safety factor evaluation associated with the state of the dam body and foundation; before, and after seal

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Mar 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Preparation, Characterization and Study of Biological Activities of New Organozinc Compounds Drived from Cytosine
...Show More Authors

The novel heterocyclic organozinc compounds were prepared from the reaction of diazonum salt cytosine zinc chloride with thymol and vanilin as coupler components. The prepared compounds were characterized by elemental analysis and UV-Vis, FTIR and 1HMNR spectroscopic techniques. The biological activity was also studied for all prepared compounds. 

View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Promoters on the Activity of Prepared Zeolite Catalyst in FCC Process
...Show More Authors

Faujasite type NaY zeolite catalyst was prepared from locally available kaolin, then the prepared NaY zeolite have been modified by exchanging of sodium ion with ammonium to produce NH4Y zeolite. NH4Y zeolite was converted to HY zeolite by ion exchanging with oxalic acid. Zinc and nickel promoters have been added to the prepared HY zeolite catalyst, and the effect of these promoters on the catalytic activity of the prepared HY catalyst was studied in fluid catalytic cracking process using light gas oil as a feedstock. The experimental results show that the promoted catalyst gives higher gas oil conversion and gasoline yield than HY zeolite catalyst at the same reaction temperature and WHSV. It was also found that the promoted catalyst gi

... Show More
View Publication Preview PDF