Background: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM) images shows inhomogeneous distribution of TNTs on screws surfaces. X-ray diffraction (XRD) patterns illustrate the covering of first group samples with ZrO2 and transformation of Ti to its oxide (Rutile phase) for second group. These pattern shows that TiO2 had higher crystallinity and larger grain size than ZrO2. Atomic Force Microscopy images (AFM) shows the increasing of roughness, grain size and internal diameter of TNTs after annealing process. Coated implant with ZrO2 at 4 month duration shows threads with newly Haversian canal feature. Annealed implant at same duration shows well developed threads, base of implant illustrates bone trabeculae filled the base of implant bed with active osteoblast cells. Conclusion: Modification of implant's surface produced an improvement of osseointegration in comparison to untreated one.
The liver is one of the most prominent glands in the digestive system. It crosses vital organs with multiple functions, including the secretion of enzymes, digestion of fats, and secretion of bile. Through histological studies and those interested in them, the tissue structure of the liver is of interest to researchers, and the four samples of Guinea pig Cavia porcellus were taken in this study to know the histological structure and compare it with rodents in particular. and other animals in general. The results of the liver parenchyma were comparable to those of the studied mammals in periods of hepatocytes, Kupffer cells, and sinusoids surrounding the central vein, blood supply, and bile ducts. He did not record differences, eve
... Show MoreThe current study was designed to investigate the histological structure of the cerebellum in the Iraqi frog
The liver is one of the most prominent glands in the digestive system. It crosses vital organs with multiple functions, including the secretion of enzymes, digestion of fats, and secretion of bile. Through histological studies and those interested in them, the tissue structure of the liver is of interest to researchers, and the four samples of Guinea pig Cavia porcellus were taken in this study to know the histological structure and compare it with rodents in particular. and other animals in general. The results of the liver parenchyma were comparable to those of the studied mammals in periods of hepatocytes, Kupffer cells, and sinusoids surrounding the central vein, blood supply, and bile ducts. He did not record differences, eve
... Show MoreThe present study deals with the morphological and histological aspects of the forebrain(Cerebrum) in the Columba livia domestica (Gmelin, 1789) to identify the histoarchitecture of its layers. This bird' has a large head found as perpendicular to the longitudinal axis. The morphological results reveal that for brain (Cerebrum) pear shaped, its outer surface is smooth without folds or deep grooves. Cerebrum is made up of two regions, the Pallium and the Subpallium. The Cerebral cortex includes four layers of hyperpallium (Wulst) , Dorsolateral corticoid area (CDL), Hippocampus, Piriform cortex. The internal cortex of cerebrum consists of Dorsal Ventricle ridge which includes the mesopallium, nidopallium, and archospallium. All these reg
... Show MoreBackground: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentineâ„¢) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10):
... Show MoreBackground: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentineâ„¢) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10):
... Show MoreCollapsible behaviour of soil is considered as one of the major problems in the stability of roadway embankment, the lack of cohesion between soil particles and its sensitivity to the change of moisture content are reasons for such problem. Creation of such cohesion may be achieved by implementation of liquid asphalt and introduction of Nano additives. In this work, silica fumes, fly ash and lime have been implemented with the aid of asphalt emulsion to improve the unconfined compressive strength of the collapsible soil. Specimens of 38 mm in diameter and 76 mm height have been prepared with various percentages of each type of Nano additive and fluid content. Specimens were subjected to unconfined compressive strength determination at dry a
... Show MoreIn this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show More