Preferred Language
Articles
/
jbcd-1505
Physical and Histological Evaluation of Coated Implant with Nano ZrO2 after Creation Titania Nanotubes
...Show More Authors

Background: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM) images shows inhomogeneous distribution of TNTs on screws surfaces. X-ray diffraction (XRD) patterns illustrate the covering of first group samples with ZrO2 and transformation of Ti to its oxide (Rutile phase) for second group. These pattern shows that TiO2 had higher crystallinity and larger grain size than ZrO2. Atomic Force Microscopy images (AFM) shows the increasing of roughness, grain size and internal diameter of TNTs after annealing process. Coated implant with ZrO2 at 4 month duration shows threads with newly Haversian canal feature. Annealed implant at same duration shows well developed threads, base of implant illustrates bone trabeculae filled the base of implant bed with active osteoblast cells. Conclusion: Modification of implant's surface produced an improvement of osseointegration in comparison to untreated one.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of Bond Strength of Acrylic Artificial Teeth with Unreinforced and Nano Silica Reinforced Denture Base Material after Chemical Disinfection
...Show More Authors

Soaking dentures with disinfection solutions is an effective way of keeping dentures in a healthy status; however, immersions in these solutions have a negative effect on the bond strength of denture base and denture teeth. The aim of this study was to evaluate the bond strength between denture acrylic teeth and heat-cured Poly (methyl methacrylate) denture base material (with and without nano silica) after disinfection with different chemical disinfectants for a simulated period of six months. One hundred specimens of maxillary central incisors attached to PMMA were divided into two groups; 50 specimens of PMMA without nano silica and 50 specimens of PMMA reinforced with 5 wt% of nano silica. Specimens of each group were immersed in five i

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 24 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Histomorphometric analysis of bone deposition at Ti implant surface dip-coated with hydroxyapatite (In vivo study)
...Show More Authors

Background: Synthetic hydroxyapatite,(Ca10(PO4)6(OH2) can directly bond to bones without infection and fibrous encapsulation, thus is regarded as bioactive and biocompatible. The aim of the study was the estimation of microarchitecture bone parameters include bone mass (gm/cm2) cortical bone width (mm), thread width (mm), marrow space star volume analysis (V*m) and osteoblast, osteocyte cell number. Materials and methods: Ninety-six (96) commercially pure titanium CpTi) used in this study, (48) implants were coated with HA by dipping coating and (48) implants were used as control. They were inserted in (32) Newzland white rabbits and followed for 2 & 6 weeks. Mechanical torque removal test and histomorphometric analysis of bone microarchit

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Mechanical and physical properties of carbon nano tubes with kevlar fiber reinforced with polyester resin
...Show More Authors

In this research study Hardness (shore D), Water absorption,
Flexural, Impact Test, and Fracture Toughness of polymer nano
composites. The polymer nano composites based on unsaturated
polyester resin reinforced with Kevlar fibers (K.F). The samples are
attended by hand lay – up method according to (Rule mixture) for
various volume fractions of unsaturated polyester resin, fiber and
carbon nanotube. The polyester resin was matrix strengthened with
3% volume fraction from Kevlar fiber and (0.5%, 1%, 1.5%, 2%)
volume fractions of carbon nanotube. The water absorption, hardness
(shore D), flexural test, impact test and toughness fracture properties
were studied. Results showed that the water absorption increas

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 24 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Localization of transforming growth factor-beta expression in the peri-implant tissues of dental implants coated with placental collagen
...Show More Authors

Back ground : The transforming growth factor beta (TGFB) signaling pathway is involved in many cellular processes in both the adult organism and the developing embryo including cell growth, cell differentiation, apoptosis. The interaction between implant material and surrounding tissues is believed to play a fundamental role in implant success and illustrates different expression of growth factors by different cells that involved in the formation of peri-implant tissue. The aim of this study was to localize expression of TGF B by newly formed bone tissue around surface-conditioned implants with placental collagen at different time intervals: 3 ,7,14,28, and 56 days . Materials and Methods: Commercially pure Titanium (CPTi) implants coated w

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 29 2018
Journal Name
Biomedical And Pharmacology Journal
Comparison of Some Mechanical and Physical Properties of three Types of Impression Materials with Different Dental Implant Angulations
...Show More Authors

Choosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue Dec 24 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Pores in Dual Nano Hydroxyapatite Coating on Thermally Oxidized Commercial Pure Titanium: Mechanical and Histological Evaluation
...Show More Authors

Background:In this study,TiO2 layer was thermally grown as a diffusion barrier on CP Ti substrate prior to electrophoretic deposition of HA coatings, to improve the coating’s compatibility also macro and micro pores in nano Hydroxyapatite dual coatings were created and their effect on the bond strength between the bone and implant was evaluated. Materials and methods: Electrophoretic Deposition technique (EPD) was used to obtain coatings for each one of four types of Hydroxyapatite(HA)on CP Ti screws (micro HA, nano HA, dual nano HA with micro pores, dual nano HA with macro pores) where carbon particles used as fugitive material to be removed by thermal treatment to create porosity.For examination of the changes occurred on the subs

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Enhanced Photocurrent of Titania Nanotube Photoelectrode Decorated with CdS Nanoparticles
...Show More Authors

In this work, CdS/TiO2 nanotubes composite nanofilms were successfully synthesized via electrodeposition technique. TiO2 titania nanotube arrays (NTAs) are commonly used in photoelectrochemical cells as the photoelectrode due to their high surface area, excellent charge transfer between interfaces and fewer interfacial grain boundaries. The anodization technique of titanium foil was used to prepare TiO2 NTAs photoelectrode. The concentration of CdCl2 played an important role in the formation of CdS nanoparticles. Field emission scanning electron microscopy (FESEM) shows that the CdS nanoparticles were well deposited onto the outer and inner of nanotube at 40 mM of CdCl2. X-ray diffraction (XRD) and energy dispersive X-ray (EDX) analyses wer

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Case Studies In Construction Materials
Enhancing asphalt binder performance through nano-SiO2 and nano-CaCO3 additives: Rheological and physical insights
...Show More Authors

During the last two decades, nanomaterial application has gained a significant attraction into asphalt technology due to their effect in enhancing asphalt binder improving the asphaltic mixture. This study will modify the asphalt binder with two different nano types, nano SiO2 and CaCO3, at levels ranging from 1% to 7%. The resulting optimum nano-modified Asphalt will be subject to a series of rheological tests, including dynamic shear rheometer (DSR), Viscosity, and bending beam rheometer (BBR) to determine asphalt binder sensitivity towards low-medium-high temperature range. Results indicate that both nano types improved the physical characteristics of Asphalt, and 5% by weight of Asphalt was suggested as a reasonable dosage of nano-SiO2

... Show More
View Publication
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Tue Dec 24 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of thermocycling and different pH of artificial saliva on the impact and transverse strength of heat cure resin reinforced with silanated ZrO2 nano-fillers.
...Show More Authors

Background: The aim of this study was to evaluate the effect of thermo cycling and different pH of artificial saliva (neutral, acidic, basic) on impact and transverse strength of heat cure acrylic resin reinforced of with 5% silanated ZrO2 nano fillers. Materials and methods: 120 samples were prepared, 60 samples for impact strength test and another 60 samples for transverse strength test, for each test, samples were divided into two major groups (before and after thermo cycling), then each of these major groups were further subdivided into 3 subgroups according to the pH of prepared artificial saliva (neutral, acidic, basic). Charpy impact device was used for impact strength test and Flexural device was used for transverse strength test. R

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 24 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of adding of modified ZrO2-TiO2 nanoparticles on certain physical and mechanical properties of heat polymerized acrylic resin
...Show More Authors

Background: The mechanical and physical properties of Polymethyl methacrylate (PMMA) don’tfulfill the entire ideal requirements of denture base materials. The purpose of this study was to produce new modified polymer nanocomposite (PMMA /ZrO2-TiO2) andassess itsimpact strength, transverse strength and thermal conductivity in comparison to the conventionalheat polymerized acrylic resin. Materials and Methods: Both ZrO2 and TiO2nano fillers were silanized with TMSPM (trimethoxysilyl propyl methacrylate) silane coupling agent before beingdispersed by ultrasonication with the methylmethacrylate (monomer) and mixed with the polymer by means of 2% by weight in (1:1) ratio, 60 specimens were constructed by conventional water bath processing

... Show More
View Publication Preview PDF