Background: The skull base and the hard palate contain many anatomical features that make them rich in information which are useful in sex differentiation; in addition to that they have the ability to resist the hardest environmental conditions that support them in making sex differentiation. Three dimensional computed tomographic techniques has important role in differentiation between sex since it offers images with very accurate data and details of all anatomical structures with high resolution. This study was made to study sex variations among Iraqi sample by craniometric linear measurements of the hard palate and the skull base using 3D reconstructed Computed Tomographic scan. Materials and methods: This study composed of 100 Iraqi subjects (50 male and 50 female) aged between 20-59 years. The sample collected from patients attending Al-Shaheed Ghazi hospital in Baghdad city to for spiral CT scanner. The craniometrical linear measurements of the hard palate and the skull base in this study were including: Maxillo-Alveolar Breadth, Maxillo-Alveolar Length, the distance between incisive foramen and greater palatine foramen (right and left), the distance between the incisor foramen and B point (the median point located at the anterior area of the magnum foramen), the distance between the incisor foramen and the anterior root of the mastoid notch on both sides (right and left), Maxillo-Alveolar Index and size of Palate. All these measurements were done by (mm) unit. Results: The statistical analysis of linear measurements of the hard palate and the skull base showed that the mean values of all measurements were significantly higher in males than females except for Maxillo-Alveolar Index was not significant and also showed that the size of the palate was the best indicator for sex variation and making the diagnosis of male with accuracy 93.3%. The age had none significant effect on these measurements. Conclusion: Three dimensional Computed Tomographic scanners is the best diagnostic tool for sex variation by the craniometrical linear measurements for the anatomical landmarks points of the hard palate and the skull base.
A comprehensive review focuses on 3D network-on-chip (NoC) simulators and plugins while paying attention to the 2D simulators as the baseline is presented. Discussions include the programming languages, installation configuration, platforms and operating systems for the respective simulators. In addition, the simulator’s properties and plugins for design metrics evaluations are addressed. This review is intended for the early career researchers starting in 3D NoC, offering selection guidelines on the right tools for the targeted NoC architecture, design, and requirements.
this worl was carried oit on 50 woman they were attended to the gynecological out patinetand non albicans vared among age group
In this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average valu
Objectives: Umbilical cord blood can be taken at birth and largely gives indication of fetal and maternal conditions. The aim of the study was to investigate the relation between sex hormones in cord blood and birth weight of newborns and pregnancy complications. Methods: Fifty cord blood samples were collected from newborns at labor room of Baghdad Teaching Hospital between May and October 2018. Blood was withdrawn from their mothers for lead analysis. Five milliliters (ml) of cord blood was taken, 3 ml was used for testosterone and estradiol analysis (using enzyme-linked immunosorbent assay) and 2 ml for lead measurement by lead care analyzer. Newborns weight and head circumference were measured. Delivered women were divided into four gro
... Show MoreThis study was conducted to investigate the relationship between corticosterone hormone in the blood of local Iraqi white chicken mothers and the sexual ratio of the hatching chicks. A field experiment located at the Poultry Research Station, Livestock Department, Agricultural Research Department, Ministry of Agriculture for the period from 16 of September 2018 to 25 of December 2018. One hundred and forty birds of Iraqi local chicken mothers (100 females+ 40 males) at the age of 28 weeks were provided from the poultry research station. The birds were raised in individual cages and distributed sequentially to the cages after the numbering of the females. Data were recorded in three periods, each period was of 28 days, and then the general a
... Show MoreBackground: The styloid process is a cylindrical bone (protrusion). It situated above the common carotid artery between the external and internal branches immediately proximal to the internal jugular vein and facial nerves. The styloid process varies in length also it may be absent as well as elongated. Classically, an elongated styloid process and calcified of stylohyoid ligament causes Eagle’s syndrome. The aim of this study was to examine the styloid process using 3 dimensional multi-detector computed tomography (3D-MDCT) to detect the presence of Eagle’s syndrome that causes severe headache and migraine. Materials and methods: One hundred patients with severe headache and migraine were exposed to 3D- multi-detector CT with special
... Show MoreIn this research, the electrical conductivity and Hall effect measurements have been investigated on the CuInTe2 (CIT) thin films prepared by thermal evaporation technique on glass substrate at room temperature as a function of annealing temperature (R.T,473,673)K for different thicknesses (300 and 600) nm. The samples were annealed for one hour. The electrical conductivity analysis results demonstrated that all samples prepared have two types of transport mechanisms of free carriers with two values of activation energy (Ea1, Ea2), and the electrical conductivity increases with the increase of annealing temperature whereas it showed opposite trend with thickness , where the electrical conductivity would d
... Show More