Preferred Language
Articles
/
jbcd-1504
Sex Variations by Linear Measurements of Palatal Bones and Skull Base Using 3D Reconstructed Computed Tomographic Scan among Iraqi Sample
...Show More Authors

Background: The skull base and the hard palate contain many anatomical features that make them rich in information which are useful in sex differentiation; in addition to that they have the ability to resist the hardest environmental conditions that support them in making sex differentiation. Three dimensional computed tomographic techniques has important role in differentiation between sex since it offers images with very accurate data and details of all anatomical structures with high resolution. This study was made to study sex variations among Iraqi sample by craniometric linear measurements of the hard palate and the skull base using 3D reconstructed Computed Tomographic scan. Materials and methods: This study composed of 100 Iraqi subjects (50 male and 50 female) aged between 20-59 years. The sample collected from patients attending Al-Shaheed Ghazi hospital in Baghdad city to for spiral CT scanner. The craniometrical linear measurements of the hard palate and the skull base in this study were including: Maxillo-Alveolar Breadth, Maxillo-Alveolar Length, the distance between incisive foramen and greater palatine foramen (right and left), the distance between the incisor foramen and B point (the median point located at the anterior area of the magnum foramen), the distance between the incisor foramen and the anterior root of the mastoid notch on both sides (right and left), Maxillo-Alveolar Index and size of Palate. All these measurements were done by (mm) unit. Results: The statistical analysis of linear measurements of the hard palate and the skull base showed that the mean values of all measurements were significantly higher in males than females except for Maxillo-Alveolar Index was not significant and also showed that the size of the palate was the best indicator for sex variation and making the diagnosis of male with accuracy 93.3%. The age had none significant effect on these measurements. Conclusion: Three dimensional Computed Tomographic scanners is the best diagnostic tool for sex variation by the craniometrical linear measurements for the anatomical landmarks points of the hard palate and the skull base.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Solving a three dimensional transportation problem using linear programming
...Show More Authors

Transport is a problem and one of the most important mathematical methods that help in making the right decision for the transfer of goods from sources of supply to demand centers and the lowest possible costs, In this research, the mathematical model of the three-dimensional transport problem in which the transport of goods is not homogeneous was constructed. The simplex programming method was used to solve the problem of transporting the three food products (rice, oil, paste) from warehouses to the student areas in Baghdad, This model proved its efficiency in reducing the total transport costs of the three products. After the model was solved in (Winqsb) program, the results showed that the total cost of transportation is (269,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 23 2023
Journal Name
Al-mustansiriyah Journal Of Science
Image Encryption Using New Non-Linear Stream Cipher Cryptosystem
...Show More Authors

In this paper, we designed a new efficient stream cipher cryptosystem that depend on a chaotic map to encrypt (decrypt) different types of digital images. The designed encryption system passed all basic efficiency criteria (like Randomness, MSE, PSNR, Histogram Analysis, and Key Space) that were applied to the key extracted from the random generator as well as to the digital images after completing the encryption process.

Publication Date
Thu Aug 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Aggregate production planning using linear programming with practical application
...Show More Authors

Abstract :

The study aims at building a mathematical model for the aggregate production planning for Baghdad soft drinks company. The study is based on a set of aggregate planning strategies (Control of working hours, storage level control strategy) for the purpose of exploiting the resources and productive capacities available in an optimal manner and minimizing production costs by using (Matlab) program. The most important finding of the research is the importance of exploiting during the available time of production capacity. In the months when the demand is less than the production capacity available for investment. In the subsequent months when the demand exceeds the available energy and to minimize the use of overti

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
A Study of the Vertical Position of the Mental Foramen using Cone-Beam Computed Tomography
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Modern Trends In Engineering And Research
Quadtree Partitioning Scheme using Fixed Predictor Base
...Show More Authors

Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in

... Show More
View Publication
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (13)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Mon Nov 09 2015
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Variations Heavy Metals Concentrations in Tigris River in Baghdad City.: Variations Heavy Metals Concentrations in Tigris River in Baghdad City.
...Show More Authors

The aim of the research is the detection of heavy metals using (Inductively coupled Plasma ICP) for samples in Tigris river at intakes of water treatment plants Baghdad (Sharq dejla, Al-Wathba, Al-Wahda, and Al-Dora) and samples at Tigris banks near (Al-Adhamya, Al-Shuhda bridge and al-Jadrya).
All the recorded results were fitted with Iraqi standers No. 25 in 1967 for all samples with heavy metals (arsenic Ar, Cadmium Cd, Chromium Cr, Zinc Zn, Lead Pb, Copper Cu, Nickel Ni, Manganese Mn, Ferrous Fe) where all concentration were lower than standard values except Cadmium (0.01- 0.014) in plants intakes and (0.027- 0.048) in river samples while the standard value is (0.005).
Other tests such as chemical oxygen demand and oil &

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Iosr Journal Of Dental And Medical Sciences (iosr-jdms)
Diabetic Cheiroarthropathy in a Sample of Iraqi Diabetic Patients
...Show More Authors

Background: Diabetic cheiroarthropathy is a term derived from the Greek word “cheiros” meaning “of the hand”, It is characterized by stiff hands with distinctively thick, tight, and waxy skin, especially on the dorsal aspects of the hands. It is part of long term complication of diabetes and many suggest it is associated with microvascular complication. The aim of the study was to determine the prevalence of diabetic cheiroarthropathy in Iraqi patients with diabetes, and to study its association with diabetic retinopathy and glycemic control. Material and Methods: A cross-sectional study in which 110 diabetic patients and 110 non-diabetic healthy people who accepted to take part in the study were ran

... Show More
Publication Date
Sun Jan 01 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Preliminary quality assurance of printgrammetry technique-3D modeling from Google Earth 3D imagery data
...Show More Authors

View Publication
Scopus Crossref