Sex Variations by Linear Measurements of Palatal Bones and Skull Base Using 3D Reconstructed Computed Tomographic Scan among Iraqi Sample
...Show More Authors

Background: The skull base and the hard palate contain many anatomical features that make them rich in information which are useful in sex differentiation; in addition to that they have the ability to resist the hardest environmental conditions that support them in making sex differentiation. Three dimensional computed tomographic techniques has important role in differentiation between sex since it offers images with very accurate data and details of all anatomical structures with high resolution. This study was made to study sex variations among Iraqi sample by craniometric linear measurements of the hard palate and the skull base using 3D reconstructed Computed Tomographic scan. Materials and methods: This study composed of 100 Iraqi subjects (50 male and 50 female) aged between 20-59 years. The sample collected from patients attending Al-Shaheed Ghazi hospital in Baghdad city to for spiral CT scanner. The craniometrical linear measurements of the hard palate and the skull base in this study were including: Maxillo-Alveolar Breadth, Maxillo-Alveolar Length, the distance between incisive foramen and greater palatine foramen (right and left), the distance between the incisor foramen and B point (the median point located at the anterior area of the magnum foramen), the distance between the incisor foramen and the anterior root of the mastoid notch on both sides (right and left), Maxillo-Alveolar Index and size of Palate. All these measurements were done by (mm) unit. Results: The statistical analysis of linear measurements of the hard palate and the skull base showed that the mean values of all measurements were significantly higher in males than females except for Maxillo-Alveolar Index was not significant and also showed that the size of the palate was the best indicator for sex variation and making the diagnosis of male with accuracy 93.3%. The age had none significant effect on these measurements. Conclusion: Three dimensional Computed Tomographic scanners is the best diagnostic tool for sex variation by the craniometrical linear measurements for the anatomical landmarks points of the hard palate and the skull base.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Postgraduate Medical Journal
Frequency of genodermatoses among Iraqi patient
...Show More Authors

HR Al-Hamami, AA Noaimi, MM Al-Waiz, AS Al-Kabraty, Iraqi Postgraduate Medical Journal, 2010 - Cited by 4

View Publication
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Comparative study of the linear and nonlinear optical properties for different Iraqi heavy and light crude oils
...Show More Authors

Iraqi oil crudes have some of the physical and chemical characteristics that distinguish it from other types of oil crudes in the world. Some of these features such us molecular composition, rheological, viscosity and emulsions are studied carefully by researchers. In this work, a comparative study of the linear and the non-linear optical properties for typical heavy and light crude oils of Iraqi origin was studied utilizing Z-scan technique. The He -Ne laser of wavelength 632.8 nm had been used for this purpose. These samples were collected from Basra and Kut oil fields. The values of the non-linear refractive index (n2), non-linear absorption coefficient (β), and third-order electrical susceptibility (χ3) were e

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer
...Show More Authors

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
linear equivalence determination of key-stream sequence using Z-Transform
...Show More Authors

the research ptesents a proposed method to compare or determine the linear equivalence of the key-stream from linear or nonlinear key-stream

View Publication Preview PDF
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Bruxism and Sleep Quality Among Iraqi Dental Students
...Show More Authors

Background: Undergraduate dental students are more susceptible to situations of stress that affected quality of sleep, such profiles of stress may result in sleep bruxism and/or awake bruxism, parafunctions that can affect oral and general health. The aim of the study was to evaluate the association of sleep bruxism, awake bruxism and sleep quality among dental students. Materials and methods: A cross-sectional study was performed including 260 Iraqi dental students from university of Baghdad aged from 20to25years old. Students enrolled in the third and fifth class participated in the study. The Pittsburgh Sleep Questionnaire Index (PSQI) was used for data collection. The PSQI was distributed during lecture classes. Sleep bruxism and awake

... Show More
View Publication
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
A Study of the Vertical Position of the Mental Foramen using Cone-Beam Computed Tomography
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (18)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Dec 15 2011
Journal Name
Iraqi Journal Of Laser
Laser Hole Drilling of Stainless Steel 321H and Steel 33 Using 3D CO2 Laser CNC Machine
...Show More Authors

In present work an investigation for precise hole drilling via continuous wave (CW) CO2 laser at 150 W maximum output power and wavelength 10.6 μm was achieved with the assistance of computerized numerical controlled (CNC) machine and assist gases. The drilling process was done for thin sheets (0.1 – 0.3 mm) of two types of metals; stainless steel (sst) 321H, steel 33 (st). Changing light and process parameters such as laser power, exposure time and gas pressure was important for getting the optimum results. The obtained results were supported with computational results using the COMSOL 3.5a software code.

View Publication Preview PDF
Publication Date
Wed Aug 30 2023
Journal Name
Baghdad Science Journal
Hepatocellular Carcinoma Prediction and early Diagnosis of Hepatitis B and C viral infection using miR-122 and miR-223 in a sample of Iraqi patients.
...Show More Authors

Hepatocellular carcinoma (HCC) is the third most common cause of cancer-related death. Therefore, it is critical for researchers to understand molecular biology in greater depth.  In several diseases including cancer, abnormal miRNA expression has been linked to apoptosis, proliferation, differentiation, and metastasis. Many miRNAs have been studied in relation to cancer, including miR-122, miR-223, and others. Hepatitis B and C viruses are the most important global risk factors for HCC. This study is intended to test whether serum miRNAs serve as a potential biomarker for both HCC and viral infections HBV and C. The expression of miRNA in 64 serum samples was analyzed by RT-qPCR. Compared to healthy volunteers, HCC patients' sera expre

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Crossref