Preferred Language
Articles
/
jbcd-1498
In Vitro Comparative Assessment of Composite Nanoleakage Using Various Dentine Surface Treatments
...Show More Authors

Background: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was conditioning with Er, Cr: YSGG laser. Group (B): dentine was conditioning with (Er, Cr: YSGG laser + acid). Group (C): dentine was conditioning with (acid + Er, Cr: YSGG laser). Group (D): dentine was conditioning with acid etch. Group (E): dentine was conditioning with acid + 10% sodium hypochlorite. For All the teeth SBMP adhesive were used and restored with Z250 composite restoration then all specimens were subjected to thermocycling 500 cycles, at 5° to 55 °C. The teeth were soaked in silver nitrate suspension. Then the teeth sectioned bucco-lingually across the centre of the restorations. The specimens were characterized using scanning electron microscopy and the amount of nanoleakage was measured by EDX spectro-analysis to identify the existence of metallic silver particles. Results: Data were analysed statistically by one way ANOVA test and (LSD) Tests. The results showed that there were statistically highly significant differences among all groups of the present study.The resultshowed that the acid and laser (group III) exhibited the lowest mean value of nanoleakage at around (6.14 %), whereas the highest mean value of nanoleakage (12.83 %) was determined by the only acid (group IV). Conclusions: Treating the acid etched dentine with Er: Cr: YSGG laser showed promising results as it exhibits lowest amount of nanoleakage of the adhesive bonding system.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental and Numerical Analysis of Laser Surface Melting by Using Enthalpy Method
...Show More Authors
Abstract<p>In this study, experimental and numerical applied of heat distribution due to pulsed Nd: YAG laser surface melting. Experimental side was consists of laser parameters are, pulse duration1.3<italic>ms</italic>, wavelength 1064nm, laser energies 1.5, 2. 6 and 4.3 J, laser beam diameter is 0.6 mm and spot diameter 0.78 mm was applied a low carbon steel type St37 with a dimension 10, 10, 3 mm, length, width and thickness respectively. Numerical analysis side consist of a mathematical model and calculating a thermal cycle by using equation in the enthalpy method applied to determine the cooling rate in fusion zone. The simulation by using the enthalpy method, applied on conduction heat transfer </p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Crossref
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Study of Aerodynamic Surface Roughness for Baghdad City Using Signal-Level Measurements
...Show More Authors

Roughness length is one of the key variables in micrometeorological studies and environmental studies in regards to describing development of cities and urban environments. By utilizing the three dimensions ultrasonic anemometer installed at Mustansiriyah university, we determined the rate of the height of the rough elements (trees, buildings and bridges) to the surrounding area of the university for a radius of 1 km. After this, we calculated the zero-plane displacement length of eight sections and calculated the length of surface roughness. The results proved that the ranges of the variables above are ZH (9.2-13.8) m, Zd (4.3-8.1) m and Zo (0.24-0.48) m.

View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Oct 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Surface Contamination and Dose Rate Verification of Fertilizers common in Iraqi Plantations using RadEye B20 Detector
...Show More Authors

Twenty three samples of granular chemical fertilizers and organic fertilizers commonly utilized in Iraqi ranches were collected. The samples were prepaid and stored in a Marinelli beaker to measure; dose rate, general count rate and surface contamination of the samples using the RadEye B20 detector, firstly with shield, secondly without the shield to estimate the effect of shielding on the measurements. The results showed that using shield made a significant decrease in the radiation measurements reached about 25%. However the mean value of surface contamination, dose rate and general count rate with shield were 0.54Bq/cm2, 0.65µsv/h, and 0.28Cps respectively, and without shield being 0.34Bq/cm2, 1.33µsv/h, and 1.52Cps respectively

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Drilling of FR-4 Composite Materials Using Single Pulse of Nd:YAG Laser
...Show More Authors

Laser drilling is capable of producing small, precisely positioned holes with high degree of reproductively. In this paper , IR millisecond Nd:YAG single pulsed laser was used to determine the effect of laser parameters on the drilled hole of the glass - fiber reinforced epoxy composite FR-4 sample of 2 mm in thickness . The type of laser source was GSI lumonics JK760TR Series laser 1.064μm system in a CNC cabin. The JK760TR series has a 0.3-50ms pulse length and a maximum repetition rate 500Hz with an average power of 600W. The investigation of single pulse laser drilling in this paper was based on theoretical and experimental solutions. In single pulse technique, the investigation included focal plane position fpp, pulse shap

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The priorities and emergency treatments of multisystem injuries associated with maxillofacial traumas
...Show More Authors

Background: The purpose of this study is to evaluate the care of multiple trauma victims with maxillofacial injuries in terms of epidemiological distributions, types of injuries, the related different modalities of surgical treatments delivered, and their complications. Materials and Methods: This prospective study was performed on 50 patients with multiple traumas including maxillofacial injuries, caused by different etiological factors, who were brought first to the surgical emergencies department of the Medical City then referred to the Maxillofacial unit in the Specialized Surgeries Hospital, Baghdad, Iraq, during the period from April 2007 to April 2008. Information was documented prospectively from the time of the emergency call to

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Apr 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Shear bond strength of different lingual buttons bonded to wet and dry enamel surfaces with resin modified glass ionomer cement (in vitro comparative study)
...Show More Authors

Background: This study was aimed to investigate the effect of three lingual button (Nickel free / rectangular base, Nickel free / round base and Composite) and bonding environment, wet and dry enamel surface, on: the shear bond strength (SBS) of light and self-cured Resin Modified Glass Ionomer Cements, and the debonding failure sites. Materials and method: One hundred twenty no-carious, free of cracks maxillary first premolar teeth were selected. Three types of orthodontic lingual buttons were used in this study: Nickel free / rectangular base, Nickel free / round base and Composite buttons. The teeth were divided into two groups of sixty teeth each. One group was used for testing the chemically cured GC Fuji Ortho Resin modified Glass Io

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Engineering
Agile manufacturing assessment model using multi-grade evaluation
...Show More Authors

In unpredicted industrial environment, being able to adapt quickly and effectively to the changing is key in gaining a competitive advantage in the global market. Agile manufacturing evolves new ways of running factories to react quickly and effectively to changing markets, driven by customized requirement. Agility in manufacturing can be successfully achieved via integration of information system, people, technologies, and business processes. This article presents the conceptual model of agility in three dimensions named: driving factor, enabling technologies and evaluation of agility in manufacturing system. The conceptual model was developed based on a review of the literature. Then, the paper demonstrates the agility

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Apr 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the cleaning efficiency of the isthmus using different rotary instrumentation techniques (In vitro study)
...Show More Authors

Background: The aims of the study were to evaluate the unclean/clean root canal surface areas with a histopathological cross section view of the root canal and the isthmus and to evaluate the efficiency of instrumentation to the isthmus using different rotary instrumentation techniques. Materials and Methods:The mesial roots of thirty human mandibular molars were divided into six groups, each group was composed of five roots (10 root canals)which prepared and irrigated as: Group one A: Protaper system to size F2 and hypodermic syringe, Group one B: Protaper system to size F2 and endoactivator system, Group two A:Wave One small then primary file and hypodermic syringe, Group two B:Wave One small then primary file and endoactivator system, Gr

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Stimulation of Phagocytic Activity of Human Polymorphonuclear Leukocytes in Vitro Using 10 mW He-Ne Laser.
...Show More Authors

Stimulative effect of 10 mW He-Ne laser on the phagocytic activity of human polymorphonuclear leukocytes( PMNs) has been studied in vitro. Normal polymorphonuclear leucocytes were isolated from the human peripheral blood. A mixture of 0.25 ml of Hanks solution, 0.25 ml of serum, 0.25 ml of Candida albicans suspension and 0.25 ml of PMNs suspension was prepared. The samples of mixture of PMNs and Candida were subdivided in 1 ml ependrof tubes and irradiated to He-Ne laser for 1, 3, 5, 10 and 20 min. The diameter of the irradiated area was 0.8 cm. For calculation of Phagocytic index before and after irradiation, the samples were incubated (37°C) at 5, 15, 30, 60 min. The slides of samples were prepared and stained using Giemsa stain. The

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 05 2010
Journal Name
Baghdad Science Journal
Propagation of Chickpea in vitro
...Show More Authors

Apical meristems, lateral buds, anthers of immature flowers and immature embryos of chickpea ( Cicer arietinum L.) were cultured on MS media with different growth regulators and incubated for 6 weeks at 25-27?C with 16 hrs photoperiod for callus initiation. Results indicated that 1 and 0.1 mg/l of 2,4-D and BA were suitable for callus initiation when apical meristems and lateral buds were used. While 2 and 0.5 mg/l of both growth regulators were essential for immature embryos. It was noticed that using chickpea anthers of the MS medium must contain 1mg/l 2ip and 0.5 mg/l IAA. However, MS medium supplemented with 1-3 mg/l of BA and 2,4-D respectively was good for callus initiation from lateral buds, anther and immature embryos.

... Show More
View Publication Preview PDF
Crossref