Preferred Language
Articles
/
jbcd-1498
In Vitro Comparative Assessment of Composite Nanoleakage Using Various Dentine Surface Treatments
...Show More Authors

Background: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was conditioning with Er, Cr: YSGG laser. Group (B): dentine was conditioning with (Er, Cr: YSGG laser + acid). Group (C): dentine was conditioning with (acid + Er, Cr: YSGG laser). Group (D): dentine was conditioning with acid etch. Group (E): dentine was conditioning with acid + 10% sodium hypochlorite. For All the teeth SBMP adhesive were used and restored with Z250 composite restoration then all specimens were subjected to thermocycling 500 cycles, at 5° to 55 °C. The teeth were soaked in silver nitrate suspension. Then the teeth sectioned bucco-lingually across the centre of the restorations. The specimens were characterized using scanning electron microscopy and the amount of nanoleakage was measured by EDX spectro-analysis to identify the existence of metallic silver particles. Results: Data were analysed statistically by one way ANOVA test and (LSD) Tests. The results showed that there were statistically highly significant differences among all groups of the present study.The resultshowed that the acid and laser (group III) exhibited the lowest mean value of nanoleakage at around (6.14 %), whereas the highest mean value of nanoleakage (12.83 %) was determined by the only acid (group IV). Conclusions: Treating the acid etched dentine with Er: Cr: YSGG laser showed promising results as it exhibits lowest amount of nanoleakage of the adhesive bonding system.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Calculating land surface temperature of South Baghdad by the using Landsat 8 images
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jan 10 2018
Journal Name
Al–bahith Al–a'alami
Quality standards and innovation in television production production processes in various fields
...Show More Authors

And the necessity for the progress of modern societies Because the scientific and objective characteristics that characterize modern societies and distinguish them from traditional societies, Is represented by the extent of its innovative achievements in the theoretical, applied and material scientific and spiritual fields. It should be noted that quality and innovation in modern societies is based on two main pillars, Standard measures for measuring and evaluating innovations to achieve their high quality, And the dissemination of the culture of innovation to spread awareness of the importance and conditions of success, and this is done by the advanced industrial countries, However, despite the great disparity between developed industri

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Stomatology
Preferences of treatments and materials used in the management of exposed pulps: a web-based questionnaire study
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of nano-hydroxy apatite on re-mineralize white spot lesions prior to orthodontic adhesive removal by different techniques (An In vitro comparative study)
...Show More Authors

Background: White-spot lesion is one of the problems associated with the fixed orthodontic treatment. The aims of this in-vitro study were to investigate enamel damage depth on adhesive removal when the adhesive were surrounded by sound, demineralized or demineralized enamel that had been re-mineralized prior to adhesive removal using 10% Nano-Hydroxy apatite and to determine the effect of three different adhesive removal techniques. Materials and methods: Composite resin adhesive (3M Unitek) was bonded to 60 human upper premolars teeth which were randomly divided in to three groups each containing ten sound teeth and ten teeth with demineralized and re-mineralized lesions adjacent to the adhesive. A window of 2 mm was prepared on the bucca

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Feb 13 2021
Journal Name
Journal Of Lasers In Medical Sciences
Effects of Different Laser Treatments on Some Properties of the Zirconia-Porcelain Interface
...Show More Authors

Introduction: This study was performed to compare the effect of Fractional CO2 laser or Q switched Nd:YAG laser of surface treatment on the shear bond strength of zirconia-porcelain interface. Methods: Fractional CO2 laser at 30 W, 2 ms, time interval 1 ms, distance between spots 0.3 mm, and number of scans is (4) or Q switched Nd:YAG laser at 30 J/mm2 and 10 Hz were used to assess the shear bond strength of zirconia to porcelain. Pre-sintered zirconia specimens were divided into three groups (n = 10) according to the surface treatment technique used: (a) untreated (Control) group; (b) CO2 group; (c) Nd:YAG group. All samples were then sintered and veneered with porcelain according to the manufacturer’s instructions. Surface morph

... Show More
View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing the Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 30 2025
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oxidation desulfurization of model oil using carbon composite derived from peach stone waste
...Show More Authors

     In this study, oxidative desulfurization of dibenzothiophene (DBT) with H2O2 as an oxidant was studied, whereas the catalyst used was zirconium oxide supported on Activated carbon (AC). Zirconium oxide (ZrO2) was impregnated over prepared activated carbon (AC) and characterized by various techniques such as XRD, FTIR, BET, SEM, and EDX. This composite was used as a heterogeneous catalyst for oxidation desulfurization of simulated oil. The results of this study showed that ZrO2/AC composite exhibited significant catalytic activity and stability, effectively lowering sulfur content under mild conditions. Factors such as reaction temperature (30, 40, 50, 60°C), time (5, 10, 15,20,30,60, 80 100 min), catalyst dose (0.3, 0.5,

... Show More
View Publication
Crossref
Publication Date
Mon Jan 18 2021
Journal Name
Materials Science And Engineering
Properties of engineered cementitious composite concrete (bendable concrete) produced using Portland limestone cement
...Show More Authors

Bendable concrete, also known as Engineered Cementitious Composite (ECC) is a type of ultra-ductile cementitious composites reinforced with fibres to control the width of cracks. It has the ability to enhance concrete flexibility by withstanding strains of 3% and higher. The properties of bendable concrete mixes (compressive strength, flexural strength, and drying shrinkage) are here assessed after the incorporation of supplementary cementitious materials, silica fume, polymer fibres, and the use of ordinary Portland cement (O.P.C) and Portland limestone cement (IL). Mixes with Portland limestone cement show lower drying shrinkage and lower compressive and flexural strength than mixes with ordinary Portland cement, due to the ratio o

... Show More
Publication Date
Wed Sep 01 2021
Journal Name
Journal Of Engineering
Thermal Buckling of Laminated Composite Plates Using a Simple Four Variable Plate Theory
...Show More Authors

In this study, the thermal buckling behavior of composite laminate plates cross-ply and angle-ply all edged simply supported subjected to a uniform temperature field is investigated, using a simple trigonometric shear deformation theory. Four unknown variables are involved in the theory, and satisfied the zero traction boundary condition on the surface without using shear correction factors, Hamilton's principle is used to derive equations of  motion depending on a Simple Four Variable Plate Theory for cross-ply and angle-ply, and then solved through Navier's double trigonometric sequence, to obtain critical buckling temperature for laminated composite plates. Effect of changing some design parameters such as, ortho

... Show More
View Publication Preview PDF
Crossref