Preferred Language
Articles
/
jbcd-1495
Comparison of the Marginal Fitness of the Ceramic Crowns Fabricated with Different CAD/CAM Systems (An In Vitro Study)
...Show More Authors

Background: The marginal fit is the most characteristic that closely related to the longevity or success of a restoration, which is absolutely affected by the fabrication technique. The objective of present in vitro study was to evaluate the effect of four different CAD/CAM systems on the marginal fit of lithiµm disilicate all ceramic crowns. Materials and Methods: Adentoform tooth of a right mandibular first molar was prepared to receive all ceramic crown restoration with deep chamfer finishing line (1mm) and axial reduction convergence angle of 6 degree, dentoform model duplicated to have Nickel-Chromiµm master die. Thirty two stone dies produce from master die and distributed randomly in to four groups (8 dies for each group) according to the type of CAD/CAM system that used: Group A: fabricated with CERAMILL motion2 (Amann Girrbach); Group B:fabricated with CEREC in lab MCXL (Sirona);Group C: fabricated with CORiTEC 250i (imes-icore); Group D: fabricated with ZIRKONZAHN M5 (Zirkonzahn). Marginal discrepancy was measured at four points at each tooth surface. Sixteen points per tooth were measured using digital stereomicroscope at (140X) magnification. Results: ANOVA and LSD post Hoc tests were used to identify and localize the source of difference among the groups. It was found that there is a highly significant difference in the marginal gap mean values between group C and group D, and highly significant differences between group A and group D. Conclusions: From the above result we can conclude that better marginal fit values were may be exhibited by CORiTEC 250i CAD/CAM system.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 15 2017
Journal Name
Journal Of Pharmacy And Biological Sciences
In-vitro effect of Artemisinin on L. tropica promastigotes
...Show More Authors

Leishmaniasis is a widespread parasitic disease caused by Leishmania parasite, this disease considers a major health problem among worldwide. Treatments available are expensive or with cytotoxic side effect. This study was aimed to investigate the effect of an herbal new compound, called artemisinin, derived from a Chinese plant called Artemisia annua. Various concentrations were studied in vitro against L. tropica amastigotes by chamber counting to investigate its effect on the proliferation of promastigotes. Three incubation periods were adopted (24, 48, 72) hours. The results showed a significant decrease in surviving promastigotes, in parallel with the normal parasite count of untreated promastigotes, along the periods studied. Th

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 30 2017
Journal Name
Iosr Journal Of Pharmacy And Biological Sciences (iosr-jpbs)
In-vitro effect of artemisinin on L. tropica promastigotes
...Show More Authors

Leishmaniasis is a widespread parasitic disease caused by Leishmania parasite, this disease considers a major health problem among worldwide. Treatments available are expensive or with cytotoxic side effect. This study was aimed to investigate the effect of an herbal new compound, called artemisinin, derived from a Chinese plant called Artemisia annua. Various concentrations were studied in vitro against L. tropica amastigotes by chamber counting to investigate its effect on the proliferation of promastigotes. Three incubation periods were adopted (24, 48, 72) hours. The results showed a significant decrease in surviving promastigotes, in parallel with the normal parasite count of untreated promastigotes, along the periods studied. This stu

... Show More
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of different curing distances on the microhardness of flowable bulk-fill composite materials
...Show More Authors

Background: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For e

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Clinical Dentistry
THE EFFECT OF A PROTECTIVE BARRIER ON THE SHEAR BOND STRENGTH OF DIFFERENT ORTHODONTIC BRACKETS
...Show More Authors

Background and objectives: This study aimed at testing the effect of plastic sleeve or barrier, used to cover the guide of the light cure unit to prevent cross-infection, on the shear bond strength and site of bond failure of stainless steel and ceramic orthodontic brackets. Materials and methods: Forty orthodontic brackets; twenty stainless steel and twenty ceramic brackets bonded to forty extracted human maxillary first premolars using light cure adhesive cured with and without the use of a protective plastic barrier on the guide. Comparing the effect of this barrier on the shear bond strength and adhesive remnant index was performed using an independent t-test and Chi-square test. Results: The protective barrier had decreased the shear b

... Show More
Scopus (3)
Scopus
Publication Date
Fri Jul 25 2014
Journal Name
Modern Sport
Analyze study for some biomechanics variables to jump shoot skill from different spots with and without defense to basketball youth players in 3x3
...Show More Authors

The research to knows some biomechanics variables in different spots with and without players in basketball youth players and analysis by using destructive method in surfing study and the research were applied for jump shoot from one of basketball players in ( middle , left , right ) in side zone and out of zone also from three point shoot with and without defense and we depend on successful shoot on analyze .The results and conclusions that center of weight of the player on standby on high and knee angel and hips were more wide also the two angle of wrist , elbow on start of shooting be more wide with defender more than without defender .the maximum high center of weight and shooting angle and ball entrance being less degree with defender

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Environmental Research
Can electrocoagulation technology be integrated with wastewater treatment systems to improve treatment efficiency?
...Show More Authors

View Publication
Scopus (77)
Crossref (72)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Environmental Research
Can electrocoagulation technology be integrated with wastewater treatment systems to improve treatment efficiency?
...Show More Authors

Considerable amounts of domestic and industrial wastewater that should be treated before reuse are discharged into the environment annually. Electrocoagulation is an electrochemical technology in which electrical current is conducted through electrodes, it is mainly used to remove several types of wastewater pollutants, such as dyes, toxic materials, oil content, chemical oxygen demand, and salinity, individually or in combination with other processes. Electrocoagulation technology used in hybrid systems along with other technologies for wastewater treatment are reviewed in this work, and the articles reviewed herein were published from 2018 to 2021. Electrocoagulation is widely employed in integrated systems with other electrochemical tech

... Show More
View Publication
Scopus (77)
Crossref (72)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
In Vitro Release Study on Capsules and Tablets Containing Enteric - Coated Granules Prepared by Wet Granulation
...Show More Authors

Wet granulation method was used instead of conventional pan coating  or fluidized –bed coating technique to prepare enteric-coated diclofenac sodium granules, using ethanolic solution of EudragitTM L100 as coating, binding and granulating agent .Addition of PEG400 or di-n-butyl phthalate as a plasticizer was found to improve the enteric property of the coat.

Part of the resulted granules was filled in hard gelatin capsules (size 0), while the other part was compressed into tablets with and without disintegrant.

The release profile of these two dosage forms in 0.1N HCl (pH 1.2)for 2 hours, and in phosphate buffer (pH 6.8) for 45 minutes as well as the release kinetic were compared with that of the en

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Preparation ultra fine particles from Ceramic refractory material using CO2 Laser
...Show More Authors

S a mples of compact magnesia and alumina were evaporated
using CO2-laser .The
Processed powders were characterized by electron microscopy
and both scanning and transmission electron microscope. The results
indicated that the particle size for both powders have reduced largely
to 0.003 nm and 0.07 nm for MgO and Al2O3, with increasing in
shape sphericity.

View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Comparison Study of Some Mechanical Properties of Epoxy Composites usinguncarbonized Orange peel and Carbonized Orange peel
...Show More Authors
Abstract<p>Inthis investigation the epoxy was reinforced by orange peel and carbonized orange peel particles with percentages (5%, 10%, 15% and 20% by weight).Mechanical tests like:Tensile, flexural,Hardness, impact and compression were carried out on these natural epoxy composites. The results showed the tensile strength have a higher value by adding (15% by weight )of orange peel and carbonized orange peel particles to epoxy,while the value (10% by weight ) of addition is suitable to get improvement in the other mechanical properties as flexural strength, Hardness, impact and compressive strength. The epoxy / carbonized orange peel powder have the best valuesin all mechanical properties than t</p> ... Show More
View Publication
Scopus (3)
Crossref (5)
Scopus Crossref