Background: With the increased in the demands of adult orthodontics, the challenge of direct bonding to non-enamel surface (zirconium) had been increased. The present study was carried out to compare the shear bond strength of three different brackets (stainless steel, sapphire and composite) bonded to zirconium surface and study the mode of bond failure. Materials and methods: The sample was comprised of 30 models (8mm *6mm*1.5mm) of full contour zirconium veneers. They were divided into three groups according to the brackets type; all samples were treated first by sandblast with aluminum oxide particle 50 µm then coated by z-prime plus primer. A central incisor bracket of each group was bonded to the prepared zirconium surface with light cure adhesive resin (Transbond TM XT, 3M Unitek, USA). Shear bond strength was measured by using Tinius Olsen universal testing machine at crosshead speed of 0.5\min. After debonding, each bracket and zirconium surface were examined using magnifying lens and adhesive remnant index was recorded. The difference in shear bond strength between main groups was analyzed by using ANOVA at p≤0.05. Results: The results revealed high significant difference among all tested groups and the highest value was for sapphire brackets (7.49±1.45 Mpa) of all groups followed by stainless steel brackets (6.46±1.43Mpa) and composite brackets had the least value (4.35±0.72). Non-significant difference in the site of bond failure among all groups of brackets and zirconium-adhesive interface failure (score III) was the predominant. Conclusion: the new zirconium prime plus primer can be successfully used in bonding stainless steel and sapphire brackets to zirconium surface.
Background: Plaque retention during fixed orthodontic therapy is an important cause of developing enamel demineralization. The purpose of this study was to evaluate the effect of different brackets types on the count of Streptococcus Mutans in orthodontic patients using conventional fluoridated toothpaste. Materials and Methods: Plaque samples were collected from maxillary 1st premolar teeth of twenty right handed patients (using split mouth technique) before bonding, after 48 hrs of bonding using tooth brush only, and after 2 weeks of using fluoridated toothpaste. Stainless steel bracket was bonded on right first premolar while the left one was bonded with sapphire bracket. The calculation of the Streptococcus Mutans count was done usin
... Show MoreIn the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in pot
... Show MoreAutorías: Ghassan Adeeb Abdulhasan, Talib Faisal Shnawa, Yasir Wajih Qaddoori. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 6, 2022. Artículo de Revista en Dialnet.
Over the last two decades, several sustainability assessment methods have developed as key accelerators for the development and improvement of sustainable industrial buildings. Some of these systems, like as LEED or BREEAM, are considered international, whereas others, such as Pearl Rating Systems (PRS), are local. Although they all share similar goals, they can lead to the construction of green buildings or the improvement of the efficiency of existing conventional buildings. Each technique has its structure, certification process, and weighting norms. The inequalities have prompted various questions about whether global assessment systems appropriately consider the country’s national settings. This study aims to compare the Pear
... Show MoreIn this paper we reported the microfabrication of three-dimensional structures using two-photon polymerization (2PP) in a mixture of MEH-PPV and an acrylic resin. Femtosecond laser operating at 800nm was employed for the two-photon polymerization processes. As a first step in this project we obtained the better composition in order to fabricate microstructers of MEH-PPV in the resin via two-photon polymerzation. Acknowledgement:This research is support by Mazur Group, Harvrad Universirt.
Web application protection lies on two levels: the first is the responsibility of the server management, and the second is the responsibility of the programmer of the site (this is the scope of the research). This research suggests developing a secure web application site based on three-tier architecture (client, server, and database). The security of this system described as follows: using multilevel access by authorization, which means allowing access to pages depending on authorized level; password encrypted using Message Digest Five (MD5) and salt. Secure Socket Layer (SSL) protocol authentication used. Writing PHP code according to set of rules to hide source code to ensure that it cannot be stolen, verification of input before it is s
... Show MoreObjective(s): In the present study, glycerin is used as a substitute for tin-foil and cold mold seal (Alginate mould seal)
in the process of curing heat and cold-cure acrylic resin denture base against stone and plaster.
Methodology: 60 specimens were prepared from heat-cure acrylic resin and cold-cure acrylic resin denture base. The
study includes 12 groups of specimens depending on the type of processing, investment material and type of
separating medium that are used in curing process. Each group of them contains 5 specimens for each test.
Some of physical properties of the processed acrylic denture base that (water sorption and solubility) have been
compared with those processed using tin-foil and tin-foil substitut