Background: Dental implant considers a unique treatment option for the replacement of missing dentition. The new trend of implants is looking for materials which accelerate bone formation in bone implant interface and enhance osseointegration to provide immediate loading directly after placement and decrease the time period which is disturbs patients and uncomfortable. The aim of the study was to evaluate the effect of nano zirconium oxide (ZrO2) and nano hydroxyapatite (Hap) mixture coating of screw shaped commercially pure titanium (cpTi) implants on bond strength at the bone implant interface with torque removal test and histological analysis in comparison with non coated implants. Materials and methods: Forty screws were machined from cpTi rods using a lathe machine. Then 20 screws coated by electrophoretic deposition method by a mixture of nano hydroxyl apatite and nano zirconium oxide, while the other 20 screws remain uncoated. The tibia of 10 adult white New Zealand experimental rabbits was chosen as implantation site, each rabbit tibia received 2 screws, one coated and the other uncoated. Torque removal test was performed to measure the torque required to remove the screw and histological analysis was performed to observe the new bone formation, after 2 and 4 weeks healing intervals. Results: Implant coated with a mixture of nano zirconium oxide and nano hydroxyl apatite showed a significantly higher removal torque values compared to uncoated one. There was more new bone formation with coated implants for both healing periods. Conclusions: Coating by electrophoresis considers a valuable process to coat metallic implants with a ceramic material and to form a uniform composite layer of coating. Osseointegration improved at bone-implant interface associated with the coated implants, which was illustrated by higher bone formation at the two intervals of time 2 weeks and 4 weeks.
Conventional concretes are almost unbending, and even a small amount of strain potential leaves them brittle. This lack of bendability is a major source of strain loss, and it has been the main goal behind the development of bendable concrete, often known with engineered ce ment composites, or ECC. This form of concrete has a lot more flexibility than regular concrete. Micromechanical polymer fibers are used to strengthen ECC. In most cases, ECC uses a 2% amount of thin, separated fibers. As a result, bendable concrete deforms but unlike traditional concrete, it does not crack. This study aims to include this kind of concrete, bendable concrete, which can be used to solve concrete problems. Karasta (CK) and Tasluja (CT) Portland Lime
... Show MoreAbstract Additive manufacturing has been recently emerged as an adaptable production process that can fundamentally affect traditional manufacturing in the future. Due to its manufacturing strategy, selective laser melting (SLM) is suitable for complicated configurations. Investigating the potential effects of scanning speed and laser power on the porosity, corrosion resistance and hardness of AISI 316L stainless steel produced by SLM is the goal of this work. When compared to rolled stainless steel, the improvement is noticeable. To examine the microstructure of the samples, the optical microscopy (OM), scanning electron microscopy (SEM), and EDX have been utilized. Hardness and tensile strength were us
... Show MoreNew schiff bases series (VIII) a-e and 1,3-thiazolidin-4-one derivatives (IX) a-e containing the 1,2,4-triazole and 1,3,4-thiazazole rings were synthesized and screening their biological activities. These compounds were identified via Fourier transform infrared (FT-IR) spectra, some via Proton nuclear magnetic resonance (1H-NMR) and mass spectra. The biological results indicated that all of these compounds did not reveal antibacterial effectiveness against (Escherichia coli and Klebsiella species) (G-). Some of these compounds showed moderate antibacterial activity against (Staphylococcus aureus, and Staphylococcus epidermidis) (G+), and all compounds exhibited moderate activity against Candida albicans.
The aim: Infection with the hepatitis B virus (HBV) caused by blood transfusion is a big problem throughout the world. The aim of study is to determine the faster and more accurate methods for detection of hepatitis B infections by serological screening and PCR- amplification. Materials and methods: A total of 140528 donors were tested for HBsAg and total anti-HBc from January to October 2021 in Iraq’s National Blood Transfusion Center; however, only 100 samples with HBsAg (-) and anti-HBc (+) were collected and tested for HBV DNA using quantitative real-time PCR. Results: From 2015 to 2021, the percentage of HBsAg positive donors was 0.33 percent in 2015, 0.32 percent in 2016, 0.30 percent in 2017, 0.28 percent in 2018, 0.23 pe
... Show MoreThe amount of protein in the serum depends on the balance between the rate of its synthesis, and that of its catabolism or loss. Abnormal metabolism may result from nutritional deficiency, enzyme deficiency, abnormal secretion of hormones, or the actions of drugs and toxins. Renal cancer is the third most common malignancy of the genitourinary system, and accounts for 3% of adult malignancies globally. Total serum proteins were measured in malignant kidney tumor, benign kidney tumors, and non tumoral kidney diseases patient groups, as well as in healthy individuals. A significant decrease (p< 0.001) of total serum protein levels in patients with malignant kidney tumors when compared with those of benign tumors, non tumoral diseases, and hea
... Show More