Background: This in vitro study was carried out to evaluate the effects of various veneering dentin ceramic thicknesses and repeated firings on the color of lithium disilicate glass-ceramic (IPS e.max Press) and zirconium-oxide (IPS ZirCAD) all-ceramic systems, measured by clinical spectrophotometers (Easyshade Advance 4.0) . Materials and methods: The 72specimens cube-shaped have the dimension of about 11 mm in width, 14 mm in length, 1mm in thickness, these cores divided into 3 groups according to the type of material each group have (24)core specimens. Each group had been divided into three sub-groups (each having 8 specimens) according to veneering with dentin ceramic thicknesses: as 0.5, 1, or 2 mm (n=8). IPS e.max press and ZirCAD cores group had been veneered with IPS e.max Ceram dentin ceramic shade A2 according to manufacturer’s instructions and the metal group had been veneered with IPS classic dentine ceramic with shade A2 according to manufacturer’s instructions. Repeat firings (3, 5 and 7 times) had been applied on all the specimens. Color differences among ceramic specimens had been measured using a clinical spectrophotometer (VITA Easyshade); the color data had been expressed according the Vita Classic shade guide. Results: The shade of all specimens had been compared inside the subgroups and with the main groups. The percentage of color agreement among the subgroups showed the color of all ceramic systems had been affecting by firing interval, the ceramic thickness and brand of ceramic. The number firings intervals applied on the all ceramic system has a significant effect on the final color, the increase of firing number change the color to a darker and reddish color. The 5th firing interval is the point at which the major color changes happened (darker shade), and in next interval (7th firing) less color changes happened. The thickness of veneering ceramic affected the color significantly. The 0.5 mm specimens in all groups showed the highest percentage of agreement (less color changes) after firing intervals, then the 1mm came and the least percentage of agreement ( highest color changes ) was the 2 mm specimens. The Brand of veneering ceramic and the type of core record a significance difference in color changes when exposed to firing heat. Conclusion: With limit of this study, the final color of the all ceramic system definitely affected by the number of firing cycle exposed to, and the veneering ceramic thickness have a clear effect on the final shade of the all ceramic tested.
The research study and analysis of the integration of marketing communications and their impact on the marketing performance of a number of telecom companies, as included in the research problem to know the role of marketing communications community in achieving sales and market share, profitability and customer satisfaction. The importance of research begins to be the right choice for the elements of marketing communications, lead to savings in time, effort and money and create a more idea about the effectiveness of the application of the concept of integration. The research to determine the role of marketing communications in promoting the integration of the marketing performance of companies in the field of sales and marke
... Show MoreBackground: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Resu
... Show MoreThis study was aimed to reduce the amount of the sprayed solution lost during trees spraying. At the same time, the concentration of the sprayed solution on the target (tree or bush) must be ensured and to find the best combination of treatments. Two factors controls the spraying process: (i) spraying speed (1.2 km/h, 2.4 km/h, 3.6 km/h), and (ii) the type of sensor. The test results showed a significant loss reduction percentage. It reached (6.05%, 5.39% and 2.05%) at the speed (1.2 km/h, 2.4 km/h, 3.6 km/h), respectively. It was noticed that when the speed becomes higher the loss becomes less accordingly. The interaction between the 3.6 km/h speed and the type of Ultrasonic sensor led to a decrease in the percentage of the spray
... Show MoreConducted two trials separate plants Defla first two seasons, 1998 and 1999 to test the susceptibility Altgveria three varieties including Azharha colored white and pink Qati and pink Qtmr and second seasons 1999 and 2000, two types color Azhaarhama white and pink Qati treated mind half-timbered two types of Alaoxinat IBA and NAA and three concentrations as well as repeatersAdhrt results low Almaah rooting
A simple setup of random number generator is proposed. The random number generation is based on the shot-noise fluctuations in a p-i-n photodiode. These fluctuations that are defined as shot noise are based on a stationary random process whose statistical properties reflect Poisson statistics associated with photon streams. It has its origin in the quantum nature of light and it is related to vacuum fluctuations. Two photodiodes were used and their shot noise fluctuations were subtracted. The difference was applied to a comparator to obtain the random sequence.
Ceramic coating compose from a ceramic mixture (MgO, Al2O3) and metall (Al-Ni) were produced by Thermal Spray Technique. The mixed ratio of used materials Al:Ni (50%) and 40% of Al2O3 and 10% MgO. This mixture was spray on a stainless steel substrate of type (316 L) by using thermal spray with flame method and at spraying distances (8, 12, 16 and 20) cm, then the prepared films were treated by laser and thermal treatment. After that performing a hardness and adhesion tests were eximined. The present study shows that the best value of the thermal treatment is 1000 ℃ for 30 mint; the optimum spray distance is 12 cm and most suitable laser is 500 mJ where the microscopic and mechanical character
... Show MoreIn low-latitude areas less than 10° in latitude angle, the solar radiation that goes into the solar still increases as the cover slope approaches the latitude angle. However, the amount of water that is condensed and then falls toward the solar-still basin is also increased in this case. Consequently, the solar yield still is significantly decreased, and the accuracy of the prediction method is affected. This reduction in the yield and the accuracy of the prediction method is inversely proportional to the time in which the condensed water stays on the inner side of the condensing cover without collection because more drops will fall down into the basin of the solar-still. Different numbers of scraper motions per hour (NSM), that is
... Show MoreA simple all optical fiber sensor based on multimode interference (MMI) for chemical liquids sensing was designed and fabricated. A segment of coreless fiber (CF) was spliced between two single mode fibers to buildup single mode-coreless-single mode (SCS) structure. Broadband source and optical signal analyzer were connected to the ends of SCS structure. De-ionized water, acetone, and n-hexane were used to test the performance of the sensor. Two influence factors on the sensitivity namely the length and the diameter of the CF were investigated. The obtained maximum sensitivity was at n-hexane at 340.89 nm/RIU (at a wavelength resolution of the optical spectrum analyzer of 0.02 nm) when the diameter of the CF reduced from 125 μm to 60 μ
... Show MoreThis work was conducted to study the treatment of industrial waste water, and more particularly those in the General Company of Electrical Industries.This waste water, has zinc ion with maximum concentration in solution of 90 ppm.
The reuse of such effluent can be made possible via appropriate treatments, such as chemical coagulation, Na2S is used as coagulant.
The parameters that influenced the waste water treatment are: temperature, pH, dose of coagulant and settling time.
It was found that the best condition for zinc removal, within the range of operation used ,were a temperature of 20C a pH value of 13 , a coagulant dose of 15 g Na2S /400ml solution and a settling time of 7 days. Under these conditions the zinc concentrat