Background:sThe aims of this study were to evaluate and compare the ability of three different techniques to obdurate simulated lateral canals, evaluate the effect of the main canal curvature on obturation of lateral canals and compare the gutta-percha penetration between coronal and apical lateral canals. Materials and methods: Resin blocks with 30 straight and 30 curved were used in this study. Each canal has two parallel lateral canals. The main canal has 0.3 mm apical diameter and 0.04 taper. The canals were divided into six groups according to canal curvature and obturation techniques used (n=10): Groups C1 and C2: straight and curved canals obturated with continuous wave technique using E&Q masterTM system. Groups O1 and O2: straight and curved canals obturated with Obtura II. Groups T1 and T2: straight and curved canals obturated with Thermafil obturators. Soapy water was used to simulate sealer in all obturations performed. The depth of gutta-percha penetration into lateral canals was measured using computerized stereomicroscope. Results: There were very highly significant differences between the obturation techniques at each lateral canal level in both straight and curved canals. Continuous wave using E&Q masterTM system exhibited the greatest gutta-percha penetration into lateral canals with very highly significant difference from both other techniques at majority of lateral canals. There was non- significant difference between Thermafil and Obtura II except at coronal lateral canal of straight main canals where the difference was very highly significant. The gutta-percha depth was greater in coronal than apical lateral canals in all groups of both straight and curved canals, and gutta-percha depth was greater in straight than in curved canals within each obturation technique. Conclusion: This study showed that all the three obturation techniques used were able to obturate simulated lateral canals with the continuous wave technique being the best. Gutta-percha depth was less in the apical than the coronal lateral canals. Canal curvature can influence the gutta-percha depth.
Several directional wells have been drilled in Majnoon oilfield at wide variation in drilling time due to different drilling parameters applied for each well. This technical paper shows the importance of proper selection of the bit, Mud type, applied weight on Bit (WOB), Revolution per minute (RPM), and flow rate based on the previous wells drilled. Utilizing the data during drilling each section for directional wells that's significantly could improve drilling efficiency presented at a high rate of penetration (ROP). Based on the extensive study of three directional wells of 35 degree inclination (MJ-51, MJ-52, and MJ-54) found that the applied drilling parameters for MJ-54 and the bit type within associated drilling parameters to drill
... Show MoreBackground: Osteoarthritis is a chronic pathology of the joints causing disability and morbidity. Diacerein is a disease-modifying agent indicated for osteoarthritis management with enhanced performance and have much lower side effects profile than conventional non-steroidal anti-inflammatory drugs. Oral administration of Diacerein is associated with a laxative effect, thus causing treatment discontinuation. Aim: This study aimed to evaluate the activity of Diacerein novasome-based transdermal gel compared with standard oral treatment in the management of induced osteoarthritis in a rat model. Materials and methods: A single intra-articular injection of monosodium iodoacetate was administered to the left knee joint, resulting in the develop
... Show MoreThis paper investigates the performance evaluation of two state feedback controllers, Pole Placement (PP) and Linear Quadratic Regulator (LQR). The two controllers are designed for a Mass-Spring-Damper (MSD) system found in numerous applications to stabilize the MSD system performance and minimize the position tracking error of the system output. The state space model of the MSD system is first developed. Then, two meta-heuristic optimizations, Simulated Annealing (SA) optimization and Ant Colony (AC) optimization are utilized to optimize feedback gains matrix K of the PP and the weighting matrices Q and R of the LQR to make the MSD system reach stabilization and reduce the oscillation of the response. The Matlab softwar
... Show MoreBackground: The study was designed to evaluate the effect of local application of exogenous VEGF/collagen I separately and as a combination in socket healing. Sixty male Albino Wistar rats were subjected for a surgical tooth extraction of upper 1st molar of both sides (right side was considered as experimental site, while left be the control one, treated with 1µL of normal saline). The rats were scarified at 3, 7, 14, 28 days post extraction. Socket healing was histologically examined with immunohistochemistochemical localization of ALP&FGF2. Materials and Method: Sixty male Albino Wistar rats were subjected for a surgical tooth extraction of upper 1stmolar of both sides (right side was considered as experimental site, while left be the
... Show MoreBackground: The excessive use and abuse of antibiotics contribute to bacterial resistance, raising the risk of complications and treatment failures. This study investigates adherence to antibiotic prescriptions among Iraqi dental patients, highlighting implications for antimicrobial resistance.Objective: To assess adherence levels and identify factors influencing antibiotic therapy compliance among dental patients.Methods: A cross-sectional survey was conducted in which adult dental patients aged 18 and older, who had been prescribed antibiotics within the past year, participated. The modified Morisky Medication Adherence Scale-8 items was used to evaluate adherence, and data were analyzed with IBM SPSS Statistics software V26.Results: Amon
... Show MoreTwo methods were established to separate cobalt from the spent catalyst CoMo which also contain Co, Al and Fe. The first method was the precipitation technique by controlling the pH. At pH 5, 76% of the cobalt which was collected with 1.4% Al and 0.5% Fe as contaminants. The second method was the anion exchange by using Amberlite 400 resin, 100% of the cobalt and was collected with 99.46% purity.The only contaminant was Fe with 0.54% with no Al. For a large scale production of cobalt from this spent catalyst, a batch process was designed with a production of 80 grams per batch by using the anion exchange technique. Kilograms quantities of Co were collected.
For the most reliable and reproducible results for calibration or general testing purposes of two immiscible liquids, such as water in engine oil, good emulsification is vital. This study explores the impact of emulsion quality on the Fourier transform infrared (FT-IR) spectroscopy calibration standards for measuring water contamination in used or in-service engine oil, in an attempt to strengthen the specific guidelines of ASTM International standards for sample preparation. By using different emulsification techniques and readily available laboratory equipment, this work is an attempt to establish the ideal sample preparation technique for reliability, repeatability, and reproducibility for FT-IR analysis while still considering t
... Show MoreABSTRACT Background:Hydrogen absorption and related degradation in the mechanical properties of Ni-Ti based orthodontic wires has been demonstrated following exposure to fluoride prophylactic agents. This study was designed to investigate the effects of three fluoride containing agents on the load deflection characteristics of heat activated nickel titanium arch wires during unloading phase. Material and method: Eighty specimens of heat activated nickel titanium arch wires were obtained from Ortho Technology Company, half of which had a 0.016 inch round and 0.019x0.025 rectangular. Ten specimens from both wire size were immersed in one of the tested fluoride prophylactic agents (neutral sodium fluoride gel, stannous fluoride gel or phos-flu
... Show MoreBackground: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surfa
... Show More