Background: Coated aesthetic archwires are currently the existing solutions for the esthetic problem, but the color of these archwires tends to change overtime. This study was aimed to evaluate the color stability of different types of esthetic archwires from four different companies at different time periods after immersion of two different staining drinks which are tea and Pepsi cola. Materials and methods: 48 specimens were prepared, each specimen contains 10 aesthetic archwires; and were divided according to type of solution into two groups: A (tea) &B (Pepsi cola); each group contained 24 specimens (12 specimens were immersed in the staining solution as 4 specimens for each time intervals and 12 specimens were immersed in distilled water as control group). Each subgroup contains one specimen from each company. Color measurements were performed by means of a computed spectrophotometer according to the Commission Internationale de I’Eclairage L*a*b* system, and color changes (ΔE*) and National Bureau of Standards units. Results: Both staining solution caused color change in variable degree and the higher amount of color instability was found for the archwires from the Hubit Company while the least amount of color change was for the archwires from the Orthotechnology Company. Conclusion: The tea caused highly significant change on the aesthetic archwires which is higher than the effect of the Pepsi cola. Key words: Color stability, aesthetic archwires, staining drinks.
Background: Green Tea is made from the leaf of the plant “Camellia sinensisâ€. Green tea is reported to contain thousands of bioactive ingredients including catechins which have shown great promise for having antimicrobial effects. Periodontal diseases represent one of the most prevalent diseases around the world and the main etiologic factor behind it, is plaque accumulation, in addition certain kinds of bacteria have been detected frequently in subjects suffering from periodontitis, Several studies suggested that the outcome of periodontal treatment is better if particular pathogens including Aggregatibacteractinomycetemcomitans can no longer be detected after therapy. Materials and Methods: plaque samples were collected from 2
... Show MoreOxidative stress is oxidative damage caused by free radicals and reactive oxygen species (ROS). These ROS can cause oxidative damage to cellular components, including membrane lipids, receptors, enzymes, proteins, and nucleic acids. It would eventually lead to cell apoptosis and the appearance of certain pathological conditions. This work investigates the antioxidant potentials of chamomile extract in vitro by evaluating the extract activity to scavenge 2,2-Diphenyl-1-picrylhydrazyl (DPPH), also in vivo by investigating its effects on oxidative stress-induced rats by assessing the total oxidant status (TOS) and total antioxidant capacity in the radiation exposed rats with and without the treatment with chamomile extract. The results
... Show MoreObjectives This study aimed to compare the clinical effectiveness of four aligning archwires: Superelastic Nickel-Titanium (Superelastic-NiTi), SmartArch, Copper-Nickel-Titanium (Cu-NiTi), and Speed Tubular coaxial-Nickel-Titanium (Tubular coaxial-NiTi), regarding the alignment efficiency, associated perception of pain, and possibility of inducing root resorption.
Materials and Methods This study includes two randomized clinical trials run in parallel. Patients with 5 to 9 mm of mandibular anterior teeth crowding according to Little's irregularity index (LII) who needed fixed orthodontic appliances without extraction were randomly assigned to four groups of
The marine collagens are biocompatible and biodegradable materials that are considered as a biomimetic approach for tissue regeneration. This study evaluated the effect of daily consumption of marine collagen supplement drink on enamel white spot lesions (WSLs), comparing the results against Regenerate system and Sylc air abrasion methods. Fifty human enamel slabs were allocated into five groups (n = 10 per group): non-treated (sound); non-treated (WSLs, 8% methylcellulose gel with 0.1 M lactic acid (pH 4.6) at 37 °C for 21 days); and three treated surfaces with marine collagen; Regenerate system; and Sylc air abrasion. The treatment lasted for 28 days followed by four weeks’ storage in artificial saliva (pH = 7.0, 37 °C). Evalu
... Show MoreThe degradation of Toluidine Blue dye in aqueous solution under UV irradiation is investigated by using photo-Fenton oxidation (UV/H2O2/Fe+). The effect of initial dye concentration, initial ferrous ion concentration, pH, initial hydrogen peroxide dosage, and irradiation time are studied. It is found put that the removal rate increases as the initial concentration of H2O2 and ferrous ion increase to optimum value ,where in we get more than 99% removal efficiency of dye at pH = 4 when the [H2O2] = 500mg / L, [Fe + 2 = 150mg / L]. Complete degradation was achieved in the relatively short time of 75 minutes. Faster decolonization is achieved at low pH, with the optimal value at pH 4 .The concentrations of degradation dye are detected by spectr
... Show MoreThe drones have become the focus of researchers’ attention because they enter into many details of life. The Tri-copter was chosen because it combines the advantages of the quadcopter in stability and manoeuvrability quickly. In this paper, the nonlinear Tri-copter model is entirely derived and applied three controllers; Proportional-Integral-Derivative (PID), Fractional Order PID (FOPID), and Nonlinear PID (NLPID). The tuning process for the controllers’ parameters had been tuned by using the Grey Wolf Optimization (GWO) algorithm. Then the results obtained had been compared. Where the improvement rate for the Tri-copter model of the nonlinear controller (NLPID) if compared with
Background: Dental caries is one of the most significant problems in world health care. Restoring carious primary teeth is one of the major treatment goals for Children, and the light activated resin restoration materials like composite, resin-modified glass ionomer and polyacid-modified which was introduced in dentistry in 1970, widely used in clinical dentistry but its application increased dramatically in recent years because of its biocompatibility, color matching, good adhesive properties of its resemblance in physical and mechanical aspects to tooth. The aim of this study: To evaluate the microleakage of Polyacid-Modified Composite resin Compared to Flowable Hybrid Composite and Resin-Modified Glass ionomer cement. Materials and me
... Show MoreT.V photo in modern shows has emerged with special characteristics and signs that have developed in cope with the development of medium and technique. This leads to adding a variety of aesthetic dimensions which are capable of attracting audience because of its communicative elements that have an important role in increasing of T.V show Watching. As a result, the research is limited to methodological Framework as the problem. The problem of the research deals with emerging the aesthetic dimensions of T.V photo. The major question is (what are the aesthetic and communicative dimension of T.V Photo?). The research aims at finding out the aesthetic dimensions of T.V photo in modern artworks. The significance of the research on the presented
... Show MoreBackground: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t
... Show More