Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chlorhexidine(0.2%( (Parodontax) and toothpaste media (Sensodyne) for (1, 7 and 28) days intervals. Moreover, this study is intended to compare the corrosion pits for each type of archwires at these different media among all intervals. Materials and Methods: In this study, two hundred forty pieces of orthodontic wires of Teflon (Hubit) coated Stainless steel (120 pieces) and epoxy (Orthotechnology) coated Stainless steel (120 pieces), rectangular in cross section, size (0.019 x 0.025) inch and 15mm in length divided into four groups according to immersion media: (dry environment group, artificial saliva group, chlorhexidine group and toothpaste group). The atomic force microscope was used to measure the corrosion pits for all samples at dry and wet conditions and after different immersion periods. Results: Statistical analysis showed that there was a highly significant increase in the corrosion pits of Teflon coated stainless steel archwires (P ≤ 0.05) in wet environment at 28 days immersion period.The highest corrosion pits were found in the toothpaste medium for the two archwire types at 28 days immersion period. Conclusion: We can conclude that Epoxy coatedstainless steel archwires are indicated to be used above Teflon coated stainless steel archwires in terms of corrosion resistance. IfTeflon coated stainless steel archwires should to be used, they should be change in shorter periods than Epoxy coated stainless steel archwires type Key words: Esthetic coated archwire, corrosion, Teflon, Epoxy, wet environment, AFM.
This study aims to identify the level of students’ awareness at Imam Muhammad bin Saud University of the requirements of married life in the light of social changes and suggested methods to deepen this awareness (according to the Islamic educational vision) from their own perspective. In this study, the researcher used the descriptive approach with a survey research method, depending on questionnaires to collect data, which he applied to students of College of Sharia in Imam Muhammad bin Saud Islamic University, as well as, students in the fields of Sociology, Social Work, and Psychology in the College of Social Sciences. The findings of the study revealed that students are aware of the requirements of married life concerning mutual ri
... Show MoreIt is no secret to everyone that the Arab individual suffers from poor self-awareness and political awareness, which made the state and the importance of its existence and preserving its institutions not among his interests, which made researchers wonder about the possibility of strengthening it and the extent of its impact on the future of building the contemporary Arab state, so the study attempted Addressing the issue of community awareness and its impact on building the state through a clear intellectual vision that blended what is social and political to define the concept of community awareness and highlight its importance and role as a basic pillar in shaping and building modern Arab countries. In the Arab world and ways to enhanc
... Show MoreTemporomandibular disorders (TMDs) were investigated in 143 pretreatment orthodontic patients (43 males and 102 females) whose age ranged between 10-25 years at the College of Dentistry, University of Baghdad, Iraq. The study was undertaken to elucidate the prevalence and severity of TMDs in malocclusion patients and to defme the relationships between malocclusion and TMDs. The clinical signs and subjective symptoms were recorded according to the principles introduced by Helkimo (1974b). Subjective symptoms were reported by 65.7% of the patients with 22.40/0 described as severe, and the most common symptoms were TMJ sounds and feeling offatigue. Clinical signs were observed in 81.8% of the sample with 22.4 and 6.3% described as moderate and
... Show MoreThe corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of
... Show MoreAbstract
Lack of safe available non-resistant treatment for visceral leishmaniasis (Kala-azar) keeps limiting the complete cure of this disease ,drugs that have toxic side effects or lack of effectiveness have led to disease relapse ,all these factors have lightened the way to the search for imperative drugs from natural resources that have been shown to have antileishmanial activity through literature survey
. In the present study, the comparative in vitro anti-leishmania activity of various fractions of Osteospermum ecklonis aerial parts fractions have been evaluated. Extracts were prepared through maceration and Soxhlet apparatus using 85% meth
... Show MoreThis paper deals with an analytical study of the flow of an incompressible generalized Burgers’ fluid (GBF) in an annular pipe. We discussed in this problem the flow induced by an impulsive pressure gradient and compare the results with flow due to a constant pressure gradient. Analytic solutions for velocity is earned by using discrete Laplace transform (DLT) of the sequential fractional derivatives (FD) and finite Hankel transform (FHT). The influences of different parameters are analyzed on a velocity distribution characteristics and a comparison between two cases is also presented, and discussed in details. Eventually, the figures are plotted to exhibit these effects.