Preferred Language
Articles
/
jbcd-1090
Cone Beam Computed Tomography in an Evaluation and Diagnosis of Anatomical Variations and Pathological Lesions in Maxillary Sinus Prior to Maxillary Sinus Lift Surgery
...Show More Authors

Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner reconstruction window in which the axial, coronal and sagittal plane could be visualized in 0.3 mm interval, 40 were smokers and 20 nonsmokers, both sides were evaluated to assess the presence of septa, maxillary sinus membrane (Schneiderian membrane)thickening, complete opacification and adenoid polyp. Result:The maxillary for nonsmoker patients (20) patients were clean and have no any pathological or anatomical changes, among smoker patients, it was found that 7 (17.5%) of them had a clean maxillary sinus, 25 (62.5%) patient from smokers, the mucosal thickening was clear and measured more than 4 mm, 20 (80%) of them bilateral maxillary sinus were involved and 5 (20%) of them have a unilateral thickening, 6 (15%) of the smoker patient have bilateral involved adenoid with max sinus, and 2(5%) of them have full opacification., no septa was found in this study. Conclusion:Cone Beam Computed Tomography(CBCT)was themost useful technique to diagnose maxillary sinusbefore maxillary sinus augmentation, an evaluation ofCone Beam Computed Tomography(CBCT)scans before implant surgery or sinus augmentation procedures has extreme clinical importance in evaluation of anatomic structures, such as thickening of the Schneiderian membrane and presence of pathological lesion such as adenoid polyp. Key words: Cone beam computed tomography, maxillary sinus, anatomical variations.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Emergency Medicine, Trauma And Acute Care
Cone beam computed tomography (CBCT) evaluation of ridge shape and bone density in Iraqi sample pre-dental implant insertion
...Show More Authors

One of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Jul 27 2021
Journal Name
Journal Of Craniofacial Surgery
Morphometric Analysis of the Mental Foramen Variation in an Iraqi Population by Using Cone-Beam Computed Tomography
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Aug 18 2023
Journal Name
Journal Of Research In Medical And Dental Science
Morphologic Evaluation of the Permanent Mandibular First Molar within an Iraqi Population Using Cone Beam Computed Tomography (Retrospective Study)
...Show More Authors

Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Cysts and Cystic-Like Lesions of the Jaws and Their Effect on Adjacent Structures by Using Cone Beam Computed Tomography (CBCT)
...Show More Authors

Background: Preoperative radiographical assessment of the maxillofacial lesions is of a great importance in guiding the surgeon during surgical procedure in reducing post-operative complications. This study highlighted the application of CBCT scan in the assessment of maxillofacial cystic and cystic like lesions as a part of advanced radiology Materials and methods: A total of 20 patients (15 males and 5 females) participated in this prospective study. CBCT scan (Kodak 9500 CBCT) with (DICOM) software utilized to perform scanning to all patients in order to assess lesion extension, morphological features and it’s relation to the adjacent vital structures. Results: In this study, the total cystic and cystic like lesions involving the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Assessment of Sagittal Condylar Position of TMJ Dysfunction in Centric Occlusion by Using Cone Beam Computed Tomography
...Show More Authors

Background: Temporomandibular joint (TMJ) is a compound articulation formed from the articular surfaces of the temporal bone and the mandibular condyle.CBCT imaging of TMJ is that it allows accurate measurements of the volume and surface of the condyle. The aim of the study is to assess the sagittal position of mandibular condyle in patients with temporomandibulardysfunction using Cone Beam Computed Tomography in centric occlusion. Materials and Methods: CBCT images for all patients were obtained in an upright position using New Tom Giano CBCT with different field of view (11 x 8), (11 x 5), and (8 x 8) and exposure factors was changed accordingly using NNT version 5.1 software for sagittal reconstruction, anterior, superior and posterior

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 10 2023
Journal Name
Journal Of Craniofacial Surgery
Cone Beam Computed Tomographic Evaluation of Schneiderian Membrane Thickness
...Show More Authors

This study aimed to determine the measurements and classification of Schneider membrane thickness correlated to age and sex factors using cone beam computed tomography (CBCT). Methods: The study included CBCT images for 100 maxillary sinuses of 50 consecutive patients, and the thickness of the maxillary sinus membrane (Schneiderian membrane) was measured in coronal view from the lowest point in the floor of the maxillary sinus to the highest point. The thickness of the Schneiderian membrane was classified into 4 types. Results: The study result revealed that out of the total cases, 45% of sinus membranes were classified as type 2, while only 10% were classified as type 4. The most frequent type of membrane thickness diagnosed in the age gro

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
The International Journal Of Oral & Maxillofacial Implants
Early Failure Rate and Associated Risk Factors for Dental Implants Placed With and Without Maxillary Sinus Augmentation: A Retrospective Study
...Show More Authors

View Publication
Scopus (22)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Al-kindy College Medical Journal
Comparative Study between Nasal Endoscopic Findings and Nose and Paranasal Sinus Computerized Tomography in diagnosis of Nose and Paranasal Sinuses Diseases
...Show More Authors

Background: Nasal obstruction is common in otorhinolaryngology outpatient visitors. The diagnosis of such compliant is by history, clinical examination and diagnostic procedures. Nasal endoscopy and computerized tomography scan are common diagnostic investigations. Nasal obstruction is either anterior or posterior (nasal septal deviations, hypertrophied turbinate pathological cyst, polyps, mass etc), or postnasal obstruction (hypertrophied turbinate, adenoid hypertrophy, nasopharyngeal cyst or nasopharyngeal tumors).

Aim of study: Prospective study to compare endoscopic finding and computerized tomography of nose, paranasal sinuses and postnasal space as diagnostic methods for nasal obstruction and other nose, p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 03 2022
Journal Name
Teikyo Medical Journal
Tooth agenesis and palatal dimensions associated with craniofacial deformity- Cone Beam Computed Tomography based study
...Show More Authors

Cleft / palate is one of the common congenital deformities in craniofacial region, associated with different types of dental anomalies like (Tooth agenesis, impaction, and supernumerary teeth) with marked changes in palatal dimensions. This study aimed to determine the prevalence of teeth agenesis and dental anomalies in cleft lip/palate patients using CBCT, and to compare the palatal dimension of cleft group with control subjects. Twenty-eight cleft cases collected during the period from 2015 to 2022, CBCT images evaluated, the study sample classified into two groups (14 bilateral and 14 unilateral cleft lip/palate) and the non-cleft control group (14 CBCT images). The presence of dental anomalies was assessed in relation to clef

... Show More
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in

... Show More
View Publication
Crossref