Background: Masseter muscle is one of the most obvious muscles of mastication and considered as one indicator of jaw muscle activity. It has a major influence on the transverse growth of the midface and the vertical growth of the mandible. This study undertaken to determine the role of cephalometric analysis for discrimination between Cl I and Cl III skeletal relationships, determine the role of ultrasonography in determination of masseter muscle thickness, compare masseter muscle thickness between Cl I and Cl III skeletal relationships, and determine the effect of gender on masseter muscle thickness. Material and Method: The sample of the current study consisted of 70 Iraqi subjects 40 males and 30 females with age ranging 18-25 years. They were divided into 2 groups depending on ANB angle: class I skeletal relationship 20 males and 15 females and class III skeletal relationship 20 males and 15 females. The collected sample included patients attended for different diagnostic purposes to the Dental Radiology Department at College of Dentistry/Babylon University, standardized lateral cephalogram was taken to determine facial morphology, six angular and eight linear measurements were assessed. Masseter muscle thickness measured ultrasonography in Al-Hilla General Teaching Hospital/Ultrasonorgaphic Department, in relaxation and contraction conditions for both sides. Results: Various parameters measured for males and females in each class and the comparison shown statistically significant differences between them (P<0.05). No difference in muscle thickness between right and left sides in the same class (P>0.05). Gender variation showed significant difference in masseter muscle thickness during rest and occlusion conditions (P<0.001). Conclusion: Cephalometric analysis served to demonstrate the skeletal morphologies and provide a base for discrimination between class I and class III skeletal relationships. Ultrasonographic scanning is an important imaging procedure. It is reproducible and simple method for accurately measuring masseter muscle thickness. The ultrasonorgaphic study has revealed variations in masseter muscle thickness among individuals with different skeletal morphologies in each gender on one hand and between males and females in each skeletal class on the other hand. Key words: Masseter muscle thickness, skeletal morphology, cephalometric analysis, ultrasonorgaphic scanning.
Pure and Fe-doped zinc oxide nanocrystalline films were prepared
via a sol–gel method using -
C for 2 h.
The thin films were prepared and characterized by X-ray diffraction
(XRD), atomic force microscopy (AFM), field emission scanning
electron microscopy (FE-SEM) and UV- visible spectroscopy. The
XRD results showed that ZnO has hexagonal wurtzite structure and
the Fe ions were well incorporated into the ZnO structure. As the Fe
level increased from 2 wt% to 8 wt%, the crystallite size reduced in
comparison with the pure ZnO. The transmittance spectra were then
recorded at wavelengths ranging from 300 nm to 1000 nm. The
optical band gap energy of spin-coated films also decreased as Fe
doping concentra
Crime is a threat to any nation’s security administration and jurisdiction. Therefore, crime analysis becomes increasingly important because it assigns the time and place based on the collected spatial and temporal data. However, old techniques, such as paperwork, investigative judges, and statistical analysis, are not efficient enough to predict the accurate time and location where the crime had taken place. But when machine learning and data mining methods were deployed in crime analysis, crime analysis and predication accuracy increased dramatically. In this study, various types of criminal analysis and prediction using several machine learning and data mining techniques, based o
Background: Preeclampsia occurs in 3-5% of
pregnancies and is a major cause (12-20 %) of
maternal mortality in developed countries. It is the
leading cause of preterm birth and intra-uterine
growth restrictions (IUGR).
Objective: The study was designed to determine and
demonstrate the ultra structural changes of
endothelial cells in placenta of women suffering from
hypertensive disease.
Patients & Methods: Placental samples were
obtained from two groups of pregnant women
groups (preeclamptic and normal pregnant women).
The specimens were fixed in 2.5% gluteraldehyde
and preceded for electron microscopic examination.
Results: Placenta of women with preeclampsia has
shown marked degenerative
Since 1990 internal combustion engines and variable systems has been considered as emission. Noise can be defined as undesirable sound, and in high levels it can be considered ahealth hazard. Large internal combustion engines produce high levels of noise. In many countries there are laws restricting the noise levels in large engine rooms and fixed applications. Locomotives engines have the minimum emission influence because of noise control techniques capability.
In this paper study on a single cylinder internal combustion engine was conducted. The engine works by adding ethanol to gasoline, at variable speeds, without adding ethanol, and with adding 10 and 20% ethanol in volumetric ratio. Using one sound insulator or two or with
... Show MoreBackground: Cisplatin is one of the most
commonly used anti-cancer drugs , but its
clinical use was limited by its nephrotoxicity .
Methods: In this study we try to investigate the
renoprotective effect of captopril and
aminophylline against cisplatin induced
nephrotoxicity .For this purpose a 36 Sprague
Dawley rats was divided randomly to 6 groups ,
each group consist of 6 rats. The first group
given normal saline and act as control group,
while the other 5 groups given cisplatin ( 7.5
mg/kg ) , captopril ( 60 mg/kg ) , aminophylline
( 24 mg/kg ) , captopril with cisplatin and
aminophylline with cisplatin respectively. All
drugs are given as single dose through
intraperitonial route. After 6
There is a suggestion that an antidiuretic hormone-induced decrease in diuresis might contribute to the rapid relief of the acute pain in renal colic. This study was designed to evaluate the efficacy of desmopressin nasal spray compared with diclofenac given intramuscularly in patients with acute renal colic. The study included 75 patients randomized into three different groups; group A received desmopressin (40 μg, nasal spray), group B diclofenac (75 mg) intramuscularly and group C, both desmopressin and diclofenac. Pain was assessed using a visual analogue scale (a 10-cm horizontal scale ranging from `no pain' to `unbearable pain') at baseline, 10, 20 and 30 min after administering t
... Show MoreThis study was aimed to reduce the amount of the sprayed solution lost during trees spraying. At the same time, the concentration of the sprayed solution on the target (tree or bush) must be ensured and to find the best combination of treatments. Two factors controls the spraying process: (i) spraying speed (1.2 km/h, 2.4 km/h, 3.6 km/h), and (ii) the type of sensor. The test results showed a significant loss reduction percentage. It reached (6.05%, 5.39% and 2.05%) at the speed (1.2 km/h, 2.4 km/h, 3.6 km/h), respectively. It was noticed that when the speed becomes higher the loss becomes less accordingly. The interaction between the 3.6 km/h speed and the type of Ultrasonic sensor led to a decrease in the percentage of the spray
... Show MoreThis study aimed to determine the measurements and classification of Schneider membrane thickness correlated to age and sex factors using cone beam computed tomography (CBCT). Methods: The study included CBCT images for 100 maxillary sinuses of 50 consecutive patients, and the thickness of the maxillary sinus membrane (Schneiderian membrane) was measured in coronal view from the lowest point in the floor of the maxillary sinus to the highest point. The thickness of the Schneiderian membrane was classified into 4 types. Results: The study result revealed that out of the total cases, 45% of sinus membranes were classified as type 2, while only 10% were classified as type 4. The most frequent type of membrane thickness diagnosed in the age gro
... Show MoreFlexible pavement design and analysis were carried out in the past with semi-experimental methods, using elastic characteristics of pavement layers. Due to the complex interferences between various layers and their time consumption, the traditional pavement analysis, and design methods were replaced with fast and powerful methods including the Finite Element Method (FEM) and the Discrete Element Method (DEM). FEM requires less computational power and is more appropriate for continuous environments. In this study, flexible pavement consisting of 5 layers (surface, binder, base, subbase, and subgrade) had been analyzed using FEM. The ABAQUS (6.14-2) software had been utilized to investigate the influence of the base layer depth on ver
... Show More