Preferred Language
Articles
/
jBh6apQBVTCNdQwCYRXC
The optoelectronic properties of CdSe:Cu photoconductive detector
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Analysing of Hueckel Edge Detector Performance Using Satellite Image
...Show More Authors

In this research, an analysis for the standard Hueckel edge detection algorithm behaviour by using three dimensional representations for the edge goodness criterion is presents after applying it on a real high texture satellite image, where the edge goodness criterion is analysis statistically. The Hueckel edge detection algorithm showed a forward exponential relationship between the execution time with the used disk radius. Hueckel restrictions that mentioned in his papers are adopted in this research. A discussion for the resultant edge shape and malformation is presented, since this is the first practical study of applying Hueckel edge detection algorithm on a real high texture image containing ramp edges (satellite image).

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Mon Mar 27 2023
Journal Name
Iranian Journal Of Materials Science And Engineering
First-Principles Analysis of Cr-Doped SrTiO 3 Perovskite as Optoelectronic Materials
...Show More Authors

The influence of Cr3+ doping on the ground state properties of SrTiO 3 perovskite was evaluated using GGA-PBE approximation. Computational modeling results infered an agreement with the previously published literature. The modification of electronic structure and optical properties due to Cr3+ introducing into SrTiO 3 were investigated. Structural parameters assumed that Cr3+ doping alters the electronic structures of SrTiO 3 by shifting the conduction band through lower energies for the Sr and Ti sites. Besides, results showed that the band gap was reduced by approximately 50% when presenting one Cr3+ atom into the SrTiO 3 system and particularly positioned at Sr sites. Interestingly, substituting Ti site by Cr3+ led to eliminating the ban

... Show More
Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
design of cdte photoconductor detector and study of some electrical
...Show More Authors

Been manufacturing detector Altosalih optical pattern contact metal semiconductor through deposition poles of aluminum metal on the chips of crystal cadmium Tleraad (CdTe) with directional [111] and growing with laboratory and annealed at a temperature 80c for 30 minutes and eat Study of some electrical properties nailed and scoutNmadj ??????? copper with non ??????? models to see effect Alichoab well research deals impact Alichoab and frequency detector resistance

View Publication Preview PDF
Publication Date
Thu Jun 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Studying Hueckel Edge Detector Using Binary Step Edge Image
...Show More Authors

Hueckel edge detector study using binary step edge image is presented. The standard algorithm that Hueckel presented, in his paper without any alteration is adopted. This paper studies a fully analysis for the algorithm efficiency, time consuming and the expected results with slide window size and edge direction. An analysis for its behavior with the changing of the slide window size (disk size) is presented. The best result is acquired when the window size equals to four pixel.  

View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Studying Hueckel edge detector using binary step edge image
...Show More Authors

Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Improvement the efficiency of SnO2/n-Si detector by engraving method using a CNC machine
...Show More Authors

Tin oxide was deposited by using vacuum thermal method on silicon wafer engraved by Computer Numerical Controlled (CNC) Machine. The inscription was engraved by diamond-made brine. Deep 0.05 mm in the form of concentric squares. Electrical results in the dark were shown high value of forward current and the high value of the detection factor from 6.42 before engraving to 10.41 after engraving. (I-V) characters in illumination with powers (50, 100, 150, 200, 250) mW/cm2 show Improved properties of the detector, Especially at power (150, 200, 250) mW/cm2. Response improved in rise time from 2.4 μs to 0.72 μs and time of inactivity improved 515.2 μs to 44.2 μs. Sensitivity angle increased at zone from 40o to 65o.

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector
...Show More Authors

In the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Malaysian Journal Of Science
DETERMINATION OF URANIUM CONCENTRATIONS IN RICE SAMPLES AVAILABLE IN THE IRAQI MARKET USING THE CR-39 DETECTOR
...Show More Authors

In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma

... Show More
View Publication
Scopus Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Effect of Aluminum on Characterization of ZnTe/n-Si Heterojunction Photo detector
...Show More Authors

View Publication
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref