Preferred Language
Articles
/
jBh6apQBVTCNdQwCYRXC
The optoelectronic properties of CdSe:Cu photoconductive detector
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Fabrication and characterization of n- InSb Heterojunction for optoelectronic device
...Show More Authors

View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Chaos synchronization delay in semiconductor lasers with optoelectronic feedback
...Show More Authors

In this work we reported the synchronization delay in
semiconductor laser (SL) networks. The unidirectional
configurations between successive oscillators and the correlation
between them are achieved. The coupling strength is a control
parameter so when we increase coupling strength the dynamic of the
system has been change. In addition the time required to synchronize
network components (delay of synchronization) has been studied as
well. The synchronization delay has been increased by mean of
increasing the number of oscillators. Finally, explanation of the time
required to synchronize oscillators in the network at different
coupling strengths.

View Publication Preview PDF
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Optik
Assessing the optoelectronic performance of d-orbital doped cubic HfO2: The case of W, Nb, and Mo
...Show More Authors

This contribution provides an atomistic understanding into the impact of W, Nb, and Mo co-substitution at Hf-site of cubic HfO2 lattice to produce Hf1−xTMxO2 system at x = 25%. The calculations have been performed under the framework of density functional theory supported by Habbured parameter (DFT+U). Structural analysis demonstrates that the recorded lattice constants is in good coherence with the previously published results. For the lattice parameters, contraction by 1.33% comparing with the host system has been reported. Furthermore, the doping effect of TM on the band gap leads to its reduction in the resulting Hf0.75TM0.25O2 configurations. The partial density of states (PDOS) indicate that hybridization through localized electroni

... Show More
Publication Date
Mon Aug 01 2022
Journal Name
Optik
Assessing the optoelectronic performance of d-orbital doped cubic HfO2: The case of W, Nb, and Mo
...Show More Authors

This contribution provides an atomistic understanding into the impact of W, Nb, and Mo co-substitution at Hf-site of cubic HfO2 lattice to produce Hf1−xTMxO2 system at x = 25%. The calculations have been performed under the framework of density functional theory supported by Habbured parameter (DFT+U). Structural analysis demonstrates that the recorded lattice constants is in good coherence with the previously published results. For the lattice parameters, contraction by 1.33% comparing with the host system has been reported. Furthermore, the doping effect of TM on the band gap leads to its reduction in the resulting Hf0.75TM0.25O2 configurations. The partial density of states (PDOS) indicate that hybridization through localized electroni

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Jan 20 2023
Journal Name
Iranian Journal Of Materials Science And Engineering
First-Principles Analysis of Cr-Doped SrTiO3 Perovskite as Optoelectronic Materials
...Show More Authors

This contribution evaluates the influence of Cr doping on the ground state properties of SrTiO3 Perovskite using GGA-PBE approximation. Results of the simulated model infer agreement with the previously published literature. The modification of electronic structure and optical properties due to Cr3+ doping levels in SrTiO3 has been investigated. Structural parameters infer that Cr3+ doping alters the electronic structures of SrTiO3 by shifting the conduction band through lower energies for the Sr and Ti sites. Substituting Ti site by Cr3+ results the energy gap in being eliminated revealing a new electrical case of conducting material for the system. Furthermore, it has been noticed that Cr doping either at Sr or Ti positions could effectiv

... Show More
Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Iranian Journal Of Materials Science And Engineering
First-Principles Analysis of Cr-Doped SrTiO3 Perovskite as Optoelectronic Materials
...Show More Authors

The influence of Cr3+ doping on the ground state properties of SrTiO3 perovskite was evaluated using GGA-PBE approximation. Computational modeling results infered an agreement with the previously published literature. The modification of electronic structure and optical properties due to Cr3+ introducing into SrTiO3 were investigated. Structural parameters assumed that Cr3+ doping alters the electronic structures of SrTiO3 by shifting the conduction band through lower energies for the Sr and Ti sites. Besides, results showed that the band gap was reduced by approximately 50% when presenting one Cr3+ atom into the SrTiO3 system and particularly positioned at Sr sites. Interestingly, substituting Ti site by Cr3+ led to eliminating the band ga

... Show More
Scopus (2)
Scopus Clarivate
Publication Date
Fri Jan 01 2016
Journal Name
Iraqi J. Sci., Special Issue, Part B
Complex Dynamics in incoherent source with ac-coupled optoelectronic Feedback
...Show More Authors

The appearance of Mixed Mode Oscillations (MMOs) and chaotic spiking in a Light Emitting Diode (LED) with optoelectronic feedback theoretically and experimentally have been reported. The transition between periodic and chaotic mixed-mode states has been investigated by varying feedback strength. In incoherent semiconductor chaotically spiking attractors with optoelectronic feedback have been observed to be the result of canard phenomena in three-dimensional phase space (incomplete homoclinic scenarios).

Preview PDF
Publication Date
Mon May 28 2018
Journal Name
Iraqi Journal Of Science
Alternative Approach to Extract the Bulk Etching Rate of PADC Nuclear Detector
...Show More Authors

     The paper aims to propose the maximum track length (Lmax) measurement as an alternative approach to evaluate and extract the bulk etch rate (Vb) of the nuclear detector PADC CR-39, and compare it with the results obtained by the removal layer thickness measurement of the etched detector. The alternative Lmax-method mainly relies on the measuring the length of the etched tracks, their maximum values and saturation times from the obtained track profile images. The detectors were irradiated with different energies of alpha particles emitted from the 241Am source and then etched in a 6.5 N NaOH solution at 70±1oC for different successive time intervals. In

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Determination the concentration of radon in human urine using LR-115 detector
...Show More Authors

In the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.

View Publication Preview PDF
Crossref