Many additives are used to improve the performance of cables in terms of increasing their flame retardancy, thermal stability, thermal conductivity, and other characteristics. Unfortunately, most of these additives contain heavy metals. Therefore, the main objective of this study is to introduce a material representing a new generation of environmentally friendly heavy metal-free stabilizers for cable grade poly(vinyl chloride) that can compete with traditional materials in terms of performance and distinctive properties. This unique additive is Oxydtron, a synthetic silicate or simply nanocement. The tests performed are rheological properties represented by a capillary rheometry analysis, limiting oxygen index, and volume resistivity. The most significant improvement in Bagley correction measurements was 14.61%; 18.13%; and 27.20% more than poly(vinyl chloride) basic formulation when using 5wt.% Oxydtron at 160 °C, 170 °C, and 180 °C, respectively. Also, the mean increases in relaxation time were 3.200 times, 8.825 times, and 12.458 times more than poly(vinyl chloride) basic formulation with 1wt.%, 3wt.%, and 5wt.% of Oxydtron, respectively. Furthermore, the Oxydtron lowered the value of the accompanying thermal gradient of the L.O.I test, reducing the heat-affected zone. The best result was with the extrusion processing method due to the uniformity of the processing conditions. However, the thermal gradient analysis showed residual heat stress in the test samples after cutting the burning layer and re-testing the samples again; this causes them to burn faster. This situation requires caution for designs that are exposed to high temperatures without burning. The optimum improvement in volume resistivity value was 14.71% and 38.24% more than poly(vinyl chloride) basic formulation after adding 5wt.% and 7wt.% of Oxydtron, respectively.
DBNRSK Sayed, Journal of Strategic Research in Social Science (JoSReSS), 2020
A new metal complexes are made from the ligands derived from amoxicillin based Schiff's base coordinated with Pd(II) and Co(II) have been synthesized and characterized via different spectroscopic methods. FT-IR spectroscopy have shown a formation of tetrahedral and square planar geometry for Co(II) and Pd(II) complexes, respectively. Surface morphology was inspected via field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM). The Brunauer–Emmett–Teller surface area of the metal complexes samples is about 6.63 to 8.71 m2/g, with pore diameters and volume of 0.030–0.0501 cm3/g and 18.39–22.98 nm, respectively. The quadrupo
In this research, a study is introduced on the effect of several environmental factors on the performance of an already constructed quality inspection system, which was designed using a transfer learning approach based on convolutional neural networks. The system comprised two sets of layers, transferred layers set from an already trained model (DenseNet121) and a custom classification layers set. It was designed to discriminate between damaged and undamaged helical gears according to the configuration of the gear regardless to its dimensions, and the model showed good performance discriminating between the two products at ideal conditions of high-resolution images. So, this study aimed at testing the system performance at poo
... Show MoreThin films of pure tin mono-sulfide SnS and tin mono-sulfide for (1,2,3,4)% fluorine SnS:F with Thicknesses of (0.85 ±0.05) ?m and (0.45±0.05) ?m respectively were prepared by chemical spray pyrolysis technique. the effect of doping of F on structural and optical properties has been studied. X-Ray diffraction analysis showed that the prepared films were polycrystalline with orthorhombic structure. It was found that doping increased the intensity of diffraction peaks. Optical properties of all samples were studied by recording the absorption and transmission spectrum in range of wave lengths (300-900) nm. The optical energy gap for direct forbidden transi
... Show MoreHerbal remedies are used in induction of lactation. In view of that .Borage Officinalis was employed to ensure an abundant milk supply or rectify milk insufficiency .However, this remedy has not been scientifically tested .The animals were treated with the aqueous extract of Borage Officinalis flowers at a daily concentration of 100 mg / kg body weight /ml for each rat through Oro-gastric tube for 14 days. Animals were subdivided into subgroups according to their physiological status. Mammary glands of these animals were processed for histological, histochemical and immunohistochemical studies. Parameters indicated that the aqueous extract of Borage Officinalis flowers induced lactogenesis in the mammmary glands of virgin and pregnant rats
... Show MoreHuman herpes virus-8 (HHV-8) infection has increased recently in Arabic countries. HHV-8 in healthy persons does not necessarily cause life-threatening infection, and however, it causes a more severe infection among immunocompromised patients. The distribution of HHV-8 genotypes varies according to ethnicity and depends on the geographic region prior rapid development of global travel. A cross sectional prospective study included a hundred healthy blood donor samples with a mean age of (36.60±10.381), 81% were positive for molecular detection of HHV-8 DNA. PCR results for HHV-8 were strongly related with risk factors such as the number of sexual relations, previous surgeries, blood transfusion, dental operation, and the number of b
... Show MoreBackground: Because of its clinical and surgical importance and lack of precise information about this rare and important anatomical landmark, this study was designed to detect the presence, configurations and length of Mandibular Retromolar Canal (MRMC) with aid of CBCT visualization. Materials and methods: In this retrospective study the data was obtained from Specialist Health Center in AL-Sadder city in Baghdad for (100) patients with 200 inferior dental canal, all of them referred to CBCT scan (Kodak 9500, French origin). The scanning was done with tube voltage 90 kVp, tube current with 10mA and exposure time was 10 s., the field of view was measured with 5cm x 3.7cmwith 0.03mm voxel size Results: In the present study the prevalence of
... Show More
