Tillage appearance device is mechanical, electric-electronic design, getting Patent from the Central Organization for Standardization and Quality Control – Industrial Property Department - Ministry of Planning – The Republic of IRAQ under number Patent 3876 in 20 / 4 / 2014, calculates the number of clods per area by Tillage appearance device, This is done through the generation electrical impulses are sent to the controlled accurate calculates number clods required space and shows the result on the screen in order to see the tillage view per area. Three factor used in these experiment, first factor represents forward speed of tractor three levels (3.5, 4.5, and 5.5 km/h), second factor represent soil moisture content at two levels (14 – 17 and 17- 20 %) and third factor was depth of tillage at three levels (10 ,15 and 20 cm) in texture silt clay loam in Wasit cityIraq. Split – split plot design under randomized complete block design with three replications and Least Significant Design 5 % was used to compare the between means of treatments. The result showed that significant differences to forward speed to the tractor on tillage appearance of more than 10 cm. Speed 5.5 km/h recorded lower number of clods 10 cm 6.5230 clods/m2. Also result showed that the increase soil moisture content from 14-17 to 17-20 % led to increase the tillage appearance more than 10 cm from 7.5178 to 9.6200 clods/m2 for tillage appearance device respectively ,while the conventional method recorded 9.1639 to 9.9400 clods/m2. Observed also depth of tillage 10 cm for the least number of clods soil more 10 cm were 6.753,6.9633 clods/m2 when used the tillage view device and conventional method respectively. There was a significant correlation between the reading of the tillage appearance device and conventional methods which means that the reading device was Accuracy.
Transient mixed convection heat transfer in a confined porous medium heated at periodic sinusoidal heat flux is investigated numerically in the present paper. The Poisson-type pressure equation, resulted from the substituting of the momentum Darcy equation in the continuity equation, was discretized by using finite volume technique. The energy equation was solved by a fully implicit control volume-based finite difference formulation for the diffusion terms with the use of the quadratic upstream interpolation for convective kinetics scheme to discretize the convective terms and the temperature values at the control volume faces. The numerical study covers a range of the hydrostatic pressure head , , , , and ), sinusoidal amplitude range of
... Show MoreIn this work, the pseudoparabolic problem of the fourth order is investigated to identify the time -dependent potential term under periodic conditions, namely, the integral condition and overdetermination condition. The existence and uniqueness of the solution to the inverse problem are provided. The proposed method involves discretizing the pseudoparabolic equation by using a finite difference scheme, and an iterative optimization algorithm to resolve the inverse problem which views as a nonlinear least-square minimization. The optimization algorithm aims to minimize the difference between the numerical computing solution and the measured data. Tikhonov’s regularization method is also applied to gain stable results. Two
... Show MoreTransient mixed convection heat transfer in a confined porous medium heated at periodic sinusoidal heat flux is investigated numerically in the present paper. The Poisson-type pressure equation, resulted from the substituting of the momentum Darcy equation in the continuity equation, was discretized by using finite volume technique. The energy equation was solved by a fully implicit control volume-based finite difference formulation for the diffusion terms with the use of the quadratic upstream interpolation for convective kinetics scheme to discretize the convective terms and the temperature values at the control volume faces. The numerical study covers a range of the hydrostatic pressure sinusoidal amplitude range and
... Show MoreThe kindergarten teacher play a role in fixing the children behavior so she must plant the value and the habits that make a positive behavior and accepted by the society so the teacher must know all the right educational psychological styles to fix the children behavior and make them accepted psychologically and socially so the problem of the research start from knowing the relation between the methods of dealing with the kindergarten’s teachers and the non right behavior appearance for the kindergarten children. The current research aims to measure the negative behavior appearance of the children of kindergarten and distinguish it according to (sex and levels) and to distinguish the most using styles by the teachers of kinderg
... Show MoreBedside clinical teaching is a fundamental part of the medical education that offers invaluable opportunities for the students to build and improve their clinical and communication skills. However, there is a growing concern about the increasing refusal of patients to participate in clinical sessions, especially in certain settings where there are sensitive cultural traditions and decreased trust in institutions.
This paper discusses patient refusal duri
Eleven hymenopterous species: two braconids, seven eulophids and two pteromalids
parasitized the larvae of Phytomyza horticola Goureau. The activity of the parasites began at
the end of April and evidently increased during May. The female of the parasites fed and
parasitized mostly on the second and third larval instars of P. horticola . Diglyphus iseae
Walker and Cirrospilus vittatus Walker were dominant larval parasites. Chrysocharis
pentheus Walker and Pediobius acantha Walker were main pupal parasites.
Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)
... Show More