Preferred Language
Articles
/
iqjmc-84
Short segment versus long segment posterior pedicular fixation of thoracolumbar fracture
...Show More Authors

Background: Fracture dislocation at the junction between thoracic and lumber segments of spinal column by direct or indirect high energy force which is usually managed with more than three vertebral level fixation. Short segment stabilization have a wide range of benefits including length of time utilized for surgical intervention, reduce functional and psychological disability postoperatively and local surgical site complications.
Objective: Evaluate the efficacy of posterior short segment pedicle stabilization in T-L fracture clinically and radiologically. Also to compare outcome of pedicle fixation by long segment and short segment an finally we try to insert at least one screw in the fracture vertebra to strengthen the stabilization in case of short segment stabilisation.
Patients and Method: This is a prospective study of 40 patients operated in medical city from Jan. 2013 to Dec. 2015.complaining from T-L fracture (T12, L1, L2) due to any type of trauma. A total of 17 of the patients (13 male and 4 female) underwent long segment fixation (group A) whereas 23(15 male and 8 female) of those patients have short segment fixation (group B). Long segment fixation includes two levels above and one or two level below with or without single screw placed in the vertebra that is broken. While short fixation involving vertebra above and vertebra below the fracture one.
Results: In tis prospective male commonly involved with the mean age 35-40 years in both groups, also most common involved vertebrae was 1st lumber. According to Modified Mcnab criteria, good result acquired by most of the patients, and using radiological Cobb angle evaluation significant loss of correction occur.
Conclusions: Short segment fixation in Thoracolumar region as effective as long segment. Short segment fixations are low coast with little complications at surgical site and need less blood replacement with less restriction of movement at the thoracolumbar junction.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Association of Admission Serum Resistin Level with Acute ST-Segment Elevation Myocardial Infarction in Iraqi Patients
...Show More Authors

Human resistin is an adipokine, with a possible link to coronary heart disease.A few studies were done about resistin in acute phase of ST-segment elevation myocardial infarction (STEMI) especially in Iraqi patients. Accordingly we design a study to investigate the association between resistin concentration and acute phase of STEMI in Iraqi patients.

The present study was carried out at Al-Yarmouk Teaching Hospital from December 2011 until June 2012. Serum resistin levels were measured in 50 patients with acute STEMI (mean age: 58.16 ± 11.73 years) at the first 12 hours of admission and 34 normal controls (mean age: 53.98 ± 15.46 years) matched for age, sex and other risk factors.

 Resistin level in patients wi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Apr 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
The role of segment reporting requirements in enhancing the volume of segmental disclosure of the Iraqi corporations
...Show More Authors

The aim of this research was to analyze the financial reporting requirements of segmental information that stipulated by the Iraqi accounting rules, investigating the extent of it compliance with the requirements of the International Financial Reporting Standard No.8 (IFRS 8) and the Statement of Financial Standards No.131 (SFAS 131). Also the research aimed to identify the segmental disclosure practices in listed corporations on Iraq Stock Exchange (ISX), basing on a hypotheses said that “the insufficient  of Iraqi financial reporting requirements of segmental information affect<

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 03 2019
Journal Name
Rawal Medical Journal
SUPERIOR VERSUS ANTERIOR PLATING OF MIDSHAFT CLAVICLE FRACTURE IN ADULT COMPARATIVE STUDY
...Show More Authors

Clavicle fractures are common injuries in young, active individuals. The majority of the fractures (80% to 85%) occur in the mid-shaft of the bone and account for approximately 2.6% of all fractures. For many years the standard treatment of fracture clavicle was the "figure-of-eight" bandage but several indications for operative fixation, the position of plate fixation for clavicle fracture remains controversial. The aim of this study is to compare between anterio—inferior and anterior-superior plating of mid-shaft displaced clavicle fracture in complications, plate prominence, nonunion, malunion and range of motion. This study is a prospective study conducted in Al-Kindy teaching hospital .A total of 30 patients with fracture mid –sh

... Show More
View Publication Preview PDF
Publication Date
Wed May 03 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Identify The Optimal Values of the Geometric Deformable Models Parameters to Segment Multiple objects in Digital Images
...Show More Authors

 Accuracy in multiple objects segmentation using geometric deformable models sometimes is not achieved for reasons relating to a number of parameters. In this research, we will study the effect of changing the parameters values on the work of the geometric deformable model and define their efficient values, as well as finding out the relations that link these parameters with each other, by depending on different case studies including multiple objects different in spacing, colors, and illumination. For specific ranges of parameters values the segmentation results are found good, where the success of the work of geometric deformable models has been limited within certain limits to the values of these parameters.

View Publication Preview PDF
Publication Date
Sun Jul 03 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Synthetic vertebral body implantation Functional outcome in management of spinal disorders
...Show More Authors

Background: Synthetic vertebral body replacement has been widely used recently to treat different spinal conditions affecting the anterior column. They arrange from trauma, infections and even tumor conditions
Objective: To assess the functional outcome of this modality in different spinal conditions.
Patients and Methods: twenty-seven cases operated from Oct. 2010 to Dec. 9 cases had spinal fractures, 8 cases with spinal tuberculosis, and 10 cases with spinal tumors. They were followed clinically for a mean period of 36 months.
Results: All the cases approached anteriorly. 5 cases had postoperative infection. No neurological worsening reported. we had dramatic neurological improvement in all spinal tuberculo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Design and Implementation of a Generalized N-Digit Binary-To-Decimal Converter on an FPGA Seven-Segment Display Using Verilog Hdl
...Show More Authors

It is often needed to have circuits that can display the decimal representation of a binary number and specifically in this paper on a 7-segment display. In this paper a circuit that can display the decimal equivalent of an n-bit binary number is designed and it’s behavior is described using Verilog Hardware Descriptive Language (HDL).
This HDL program is then used to configure an FPGA to implement the designed circuit.

View Publication Preview PDF
Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
K. wire fixation versus conservative treatment of closed displaced intra-articular calcaneal fractures
...Show More Authors

Background: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use. The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displaced intra-art

... Show More
Preview PDF
Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Measuring Lower Uterine Segment Thickness Using Abdominal Ultrasound to Predict Timing of Cesarean Section in Women with Scarred Uterus at Elwiya Maternity Teaching Hospital
...Show More Authors

Background: Ultrasonography has been used to examine the thickness of the lower uterine segment in women with previous cesarean sections in an attempt to predict the risk of scar dehiscence during subsequent pregnancy. The predictive value of such measurement has not been adequately assessed. Objectives: To correlate lower uterine segment thickness measured by trans abdominal ultrasound in pregnant women with previous cesarean section with that measured during cesarean section by caliper and to find out minimum lower uterine segment thickness indicative of integrity of the scar.Methods: A prospective observational study at Elwyia Maternity Teaching Hospital, from January 2011 to January 2012. A total of 143 women were enrolled in the stu

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2013
Journal Name
Journal Of Engineering
Design and Implementation of a Generalized N-Digit Binary-To-Decimal Converter on an FPGA Seven-Segment Display Using Verilog Hdl Design and Implementation of a Generalized N-Digit Binary-To-Decimal Converter on an FPGA Seven-Segment Display Using Verilog Hdl
...Show More Authors

It is often needed to have circuits that can display the decimal representation of a binary number and specifically in this paper on a 7-segment display. In this paper a circuit that can display the decimal equivalent of an n-bit binary number is designed and it’s behavior is described using Verilog Hardware Descriptive Language (HDL). This HDL program is then used to configure an FPGA to implement the designed circuit.

Publication Date
Wed Sep 01 2021
Journal Name
Expert Systems With Applications
A long short-term recurrent spatial-temporal fusion for myoelectric pattern recognition
...Show More Authors

View Publication
Scopus (17)
Crossref (17)
Scopus Clarivate Crossref