Background:Image guided transthoracic needle biopsy (TTNB) has great diagnostic value for the definitive characterization of lung lesions and is an established primary procedure to diagnose pulmonary nodules. It is traditionally performed as an outpatient procedure. It is safe, accurate, sensitive, and can obviate surgical procedure.
Objective: to assess the accuracy and safety of CT-guided TTNB in Baghdad Teaching Hospital
Patients & Methods: From December 2009 to September 2011, we conducted a prospective study of 43 consecutive outpatient and inpatient lung biopsies. An informed consent was obtained from the patients. No sedation is required. All biopsies were performed using CT guidance without CT fluoroscopy and were performed under local anesthesia using a 16 gauge core biopsy needle with internal automated gun. A posteroanterior inspiratory CXR was obtained 30 minutes after biopsy. All complications were recorded. If there was no pneumothorax, the patient was discharged. If there was a small asymptomatic pneumothorax, serial radiographs has been performed, patients also were discharged if no change in size was noted.
Results: A total of 43 patients underwent CT guided TTNB of peripheral lung lesions (mean age 60 years) and a male to female ratio of 28:15. The operation was successful in 40 out of 43 patients. The sample was adequate in 39 out of 43 patients. Complications were recorded in 4 patients (the most common complication was pneumothorax). No patient needed chest tube insertion.
Conclusion: CT guided TTNB is safe and an accurate procedure and can be performed as an outpatient procedure under local anesthesia.
Patient safety is the main issue in health care organization, the Agency for Healthcare Research and Quality defines it as, “freedom from accidental or preventable injuries produced by medical care. Thus, practices or interventions that improve patient safety are those that reduce the occurrence of preventable adverse events”. The purpose of this study was to evaluate Iraqi pharmacist perception about the culture of patient safety. As well as estimate whether safety is a principal issue in their pharmaceutical practice this study was carried out on 435 pharmacists who are working in community pharmacies in various Iraqi provinces. A survey was distributed via the internet during the period from May to June 2020. A community pharmacy
... Show MoreStandardized uptake values, often known as SUVs, are frequently utilized in the process of measuring 18F-fluorodeoxyglucose (FDG) uptake in malignancies . In this work, we investigated the relationships between a wide range of parameters and the standardized uptake values (SUV) found in the liver. Examinations with 18F-FDG PET/CT were performed on a total of 59 patients who were suffering from liver cancer. We determined the SUV in the liver of patients who had a normal BMI (between 18.5 and 24.9) and a high BMI (above 30) obese. After adjusting each SUV based on the results of the body mass index (BMI) and body surface area (BSA) calculations, which were determined for each patient based on their height and weight. Under a variety of dif
... Show MoreSteganography is defined as hiding confidential information in some other chosen media without leaving any clear evidence of changing the media's features. Most traditional hiding methods hide the message directly in the covered media like (text, image, audio, and video). Some hiding techniques leave a negative effect on the cover image, so sometimes the change in the carrier medium can be detected by human and machine. The purpose of suggesting hiding information is to make this change undetectable. The current research focuses on using complex method to prevent the detection of hiding information by human and machine based on spiral search method, the Structural Similarity Index Metrics measures are used to get the accuracy and quality
... Show MoreBreast cancer is the most common malignancy in female and the most registered cause of women’s mortality worldwide. BI-RADS 4 breast lesions are associated with an exceptionally high rate of benign breast pathology and breast cancer, so BI-RADS 4 is subdivided into 4A, 4B and 4C to standardize the risk estimation of breast lesions. The aim of the study: to evaluate the correlation between BI-RADS 4 subdivisions 4A, 4B & 4C and the categories of reporting FNA cytology results. A case series study was conducted in the Oncology Teaching Hospital in Baghdad from September 2018 to September 2019. Included patients had suspicious breast findings and given BI-RADS 4 (4A, 4B, or 4C) in the radiological report accordingly. Fine needle aspirati
... Show MoreBackground: Ultrasound guided fine needle aspiration (FNA) is a quick nonmorbid method of staging disease in the axilla,Color doppler ultrasound is used to differentiate benign lymph node from node that bears metastasis.
Objective: To evaluate the utility of ultrasound guided (FNA) of the axillary L.N depending on the size of the primary tumor and the appearance of the lymph node by ultrasound , and to document the difference in color Doppler flow features between benign and malignant lymph node in women with primary breast cancer.
Patients and methods: The total number of the patient in the study is (60). Data were collected about tumor size, lymph node appearance and color-power Doppler sonography compared to the result of ultras
A three-dimensional (3D) model extraction represents the best way to reflect the reality in all details. This explains the trends and tendency of many scientific disciplines towards making measurements, calculations and monitoring in various fields using such model. Although there are many ways to produce the 3D model like as images, integration techniques, and laser scanning, however, the quality of their products is not the same in terms of accuracy and detail. This article aims to assess the 3D point clouds model accuracy results from close range images and laser scan data based on Agi soft photoscan and cloud compare software to determine the compatibility of both datasets for several applications. College of Scien
... Show MoreAssessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.
In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.
To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) de
... Show MoreOpenStreetMap (OSM), recognised for its current and readily accessible spatial database, frequently serves regions lacking precise data at the necessary granularity. Global collaboration among OSM contributors presents challenges to data quality and uniformity, exacerbated by the sheer volume of input and indistinct data annotation protocols. This study presents a methodological improvement in the spatial accuracy of OSM datasets centred over Baghdad, Iraq, utilising data derived from OSM services and satellite imagery. An analytical focus was placed on two geometric correction methods: a two-dimensional polynomial affine transformation and a two-dimensional polynomial conformal transformation. The former involves twelve coefficients for ad
... Show More<p>Analyzing X-rays and computed tomography-scan (CT scan) images using a convolutional neural network (CNN) method is a very interesting subject, especially after coronavirus disease 2019 (COVID-19) pandemic. In this paper, a study is made on 423 patients’ CT scan images from Al-Kadhimiya (Madenat Al Emammain Al Kadhmain) hospital in Baghdad, Iraq, to diagnose if they have COVID or not using CNN. The total data being tested has 15000 CT-scan images chosen in a specific way to give a correct diagnosis. The activation function used in this research is the wavelet function, which differs from CNN activation functions. The convolutional wavelet neural network (CWNN) model proposed in this paper is compared with regular convol
... Show More<p>Analyzing X-rays and computed tomography-scan (CT scan) images using a convolutional neural network (CNN) method is a very interesting subject, especially after coronavirus disease 2019 (COVID-19) pandemic. In this paper, a study is made on 423 patients’ CT scan images from Al-Kadhimiya (Madenat Al Emammain Al Kadhmain) hospital in Baghdad, Iraq, to diagnose if they have COVID or not using CNN. The total data being tested has 15000 CT-scan images chosen in a specific way to give a correct diagnosis. The activation function used in this research is the wavelet function, which differs from CNN activation functions. The convolutional wavelet neural network (CWNN) model proposed in this paper is compared with regular convol
... Show More