Modified Automated Scoring system for Immunohistochemical staining using commercially available low cost software for image analysis

Background: During the past several years, there has been a rapidly escalating clinical need to perform IHC stains that require quantitative interpretation. Automated Cellular
Imaging System is used to analyze immunohistochemically stained slides, primarily for cancer-related diagnostics. Studies have shown that the device offers accuracy,
precision, and reproducibility of immunostained slide analysis exceeding that possible with manual evaluation, which was the prevailing method.
Aim of the study In this article we will demonstrate that meaningful image analysis of immunohistochemical staining studies can be performed using inexpensive, widely distributed
graphics software (Adobe Photoshop) on a personal computer. Also we will try to use a modified digital scoring system depending on the percentage of pixels that are showing a given
stain with regard to the total area of the slide. We select three sets for each antigen (one is optimally stained, one is insufficiently stained and third one is not stained one)
materials and methods Thirty digital pictures of immunohistochemically stained slides with monoclonal antibodies against different antigens, from standard quality control lab
(NORDIQC) and then were analyzed by Adobe Photoshop software, then we distribute the percent of pixels showing a giving band of the brown color into five groups, then we compare
those results in the three groups.
Results: Results showed that there was significant difference between color bands of the same tissue among optimal and insufficient staining (P<0.05), also there was significant difference between the group of slides that were optimally stained with those insufficiently stained (p<0.05), that’s to say the procedure of scoring that was done was accurate in discriminating between optimal staining and insufficient staining
Conclusion: Each slide was converted into a matrix of data that describe every pixel in the slide and by that we can compare between all slides that’s to say we convert the visual manual
evaluation into an automated objective analysis, which is the first step in establishing quantitative immunohistochemistry.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 30 2022
Journal Name
Iraqi Journal Of Science
Modified Blowfish Algorithm for Image Encryption using Multi Keys based on five Sboxes

In this paper, a new modification was proposed to enhance the security level in the Blowfish algorithm by increasing the difficulty of cracking the original message which will lead to be safe against unauthorized attack. This algorithm is a symmetric variable-length key, 64-bit block cipher and it is implemented using gray scale images of different sizes. Instead of using a single key in cipher operation, another key (KEY2) of one byte length was used in the proposed algorithm which has taken place in the Feistel function in the first round both in encryption and decryption processes. In addition, the proposed modified Blowfish algorithm uses five Sboxes instead of four; the additional key (KEY2) is selected randomly from additional Sbox

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Journal Of Ecological Engineering
Scopus Clarivate Crossref
View Publication
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study the Performance of Low Cost Material (Peanut Hulls) for Dye Adsorption Using Inverse Fluidized Bed

The present study dealt with the removal of methylene blue from wastewater by using peanut hulls (PNH) as adsorbent. Two modes of operation were used in the present work, batch mode and inverse fluidized bed mode. In batch experiment, the effect of peanut hulls doses 2, 4, 8, 12 and 16 g, with constant initial pH =5.6, concentration 20 mg/L and particle size 2-3.35 mm were studied. The results showed that the percent removal of methylene blue increased with the increase of peanut hulls dose. Batch kinetics experiments showed that equilibrium time was about 3 hours, isotherm models (Langmuir and Freundlich) were used to correlate these results. The results showed that the (Freundlich) model gave the best fitting for adsorption capacity. D

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 12 2016
Journal Name
Wireless Networks
Low communication cost (LCC) scheme for localizing mobile wireless sensor networks

In recent years, the number of applications utilizing mobile wireless sensor networks (WSNs) has increased, with the intent of localization for the purposes of monitoring and obtaining data from hazardous areas. Location of the event is very critical in WSN, as sensing data is almost meaningless without the location information. In this paper, two Monte Carlo based localization schemes termed MCL and MSL* are studied. MCL obtains its location through anchor nodes whereas MSL* uses both anchor nodes and normal nodes. The use of normal nodes would increase accuracy and reduce dependency on anchor nodes, but increases communication costs. For this reason, we introduce a new approach called low communication cost schemes to reduce communication

... Show More
Scopus (33)
Crossref (26)
Scopus Clarivate Crossref
View Publication
Publication Date
Wed Apr 01 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Evaluation of Performance Characteristics of different Commercially available Diagnostic tests for hepatitis C virus antibodies in major Public Laboratories in Baghdad

Background: Immunoassays are one of the oldest techniques used in diagnostic virology where a number of serologic techniques, with different degrees of sensitivity and specificity, for the detection of HCV antigens and their specific antibodies, have been developed.
Materials and methods: One hundred and four sera samples were collected from National Center for Blood Transfusion, Gastroenterology and Liver Diseases Hospital, Central Public Health Laboratories and Teaching Laboratories. According to the manufacturers practical instructions, many available methods for detecting Anti-HCV antibodies, including enzyme linked immunosorbent assay (ELISA), immunochromatographic assay (ICA), recombinant immunoblot

... Show More
Crossref
View Publication Preview PDF
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Link Failure Recovery for a Large-Scale Video Surveillance System using a Software-Defined Network

The software-defined network (SDN) is a new technology that separates the control plane from data plane for the network devices. One of the most significant issues in the video surveillance system is the link failure. When the path failure occurs, the monitoring center cannot receive the video from the cameras. In this paper, two methods are proposed to solve this problem.  The first method uses the Dijkstra algorithm to re-find the path at the source node switch. The second method uses the Dijkstra algorithm to re-find the path at the ingress node switch (or failed link).

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Information Engineering And Applications
Development of Prognosis Factors in a Scoring System for Predicting of Breast Cancer Mortality

Today, the prediction system and survival rate became an important request. A previous paper constructed a scoring system to predict breast cancer mortality at 5 to 10 years by using age, personal history of breast cancer, grade, TNM stage and multicentricity as prognostic factors in Spain population. This paper highlights the improvement of survival prediction by using fuzzy logic, through upgrading the scoring system to make it more accurate and efficient in cases of unknown factors, age groups, and in the way of how to calculate the final score. By using Matlab as a simulator, the result shows a wide variation in the possibility of values for calculating the risk percentage instead of only 16. Additionally, the accuracy will be calculate

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Low Cost Heart Rate Monitor Using Led-Led Sensor

A high sensitivity, low power and low cost sensor has been developed for photoplethysmography (PPG) measurement. The PPG principle was applied to follow the dilatation and contraction of skin blood vessels during the cardiac cycle. A standard light emitting diodes (LEDs) has been used as a light emitter and detector, and in order to reduce the space, cost and power, the classical analogue-to-digital converters (ADCs) replaced by the pulse-based signal conversion techniques. A general purpose microcontroller has been used for the implementation of measurement protocol. The proposed approach leads to better spectral sensitivity, increased resolution, reduction in cost, dimensions and power consumption. The basic sensing configuration prese

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Open Engineering
Producing low-cost self-consolidation concrete using sustainable material
Abstract<p>The disposal of the waste material is the main goal of this investigation by transformation to high-fineness powder and producing self-consolidation concrete (SCC) with less cost and more eco-friendly by reducing the cement weight, taking into consideration the fresh and strength properties. The reference mix design was prepared by adopting the European guide. Five waste materials (clay brick, ceramic, granite tiles, marble tiles, and thermostone blocks) were converted to high-fine particle size distribution and then used as 5, 10, and 15% weight replacements of cement. The improvement in strength properties is more significant when using clay bricks compared to other activated waste </p> ... Show More
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
View Publication
Publication Date
Sat Jan 01 2022
Journal Name
Open Engineering
Producing low-cost self-consolidation concrete using sustainable material
Abstract<p>The disposal of the waste material is the main goal of this investigation by transformation to high-fineness powder and producing self-consolidation concrete (SCC) with less cost and more eco-friendly by reducing the cement weight, taking into consideration the fresh and strength properties. The reference mix design was prepared by adopting the European guide. Five waste materials (clay brick, ceramic, granite tiles, marble tiles, and thermostone blocks) were converted to high-fine particle size distribution and then used as 5, 10, and 15% weight replacements of cement. The improvement in strength properties is more significant when using clay bricks compared to other activated waste </p> ... Show More
Crossref (7)
Crossref
View Publication