Background: The surgical treatment of pilonidal sinus varies from wide excision and laying the wound open or excision with primary closure or excision with the use of skin graft in some special cases.
Objectives: The objectives of this study is to determine the efficacy of treating non complicated pilonidal sinus disease with minimal excision and primary closure technique, complications and recurrence rate.
Patients and methods: This is a prospective study conducted in shahid ahmed ismaiel hospital in rania – As sulaimania IRAQ during the period from December 2013 to January 2016 and was carried on one hundred (100) consecutive patients with non complicated non recurrent pilonidal sinus patients who were treated with minimal excision and primary closure technique. The data were analyzed focusing mainly on complications mainly infection, gapping, wound disruption, recurrence rate and patient’s compliance to antibiotics use and local wound care.The results obtained were compared with other similar studies.
Result: One hundred patients with non complicated pilonidal sinus were treated with minimal excision and primary closure technique.Fifteen patients developed superficial wound infection, seventeen patients developed simple superficial wound gapping .Three patients developed deep wound infection with disruption. Four patients developed recurrence and they were treated with re-excision and skin graft placement. Minimal follow up was six months, Operations were done under general or spinal anesthesia .operative time ranged between 12 to 22 minutes (mean time 17 minutes).
Conclusion: Minimal excision and primary closure technique for the treatment of pilonidal sinus disease is associated with short hospital stay, shorter off work time, less cost, low complications rate and low chance of recurrence.
Abdominal fat synthesizes a variety of adipokines, including vaspin and chemerin, that affect the resistance to insulin. This research was conducted to demonstrate the effect of pioglitazone, one insulin sensitizer used to decrease insulin resistance, on these adipokines in obese patients with polycystic ovary (PCOS). Twenty-five obese women with PCOS were treated with pioglitazone 15mg/bid for 12 weeks. Modifications in fasting blood glucose (FBG), serum fasting insulin (FSI), chemerin and vaspin serum levels, follicle stimulation hormone (FSH), luteinizing hormone (LH), testosterone (T), and in baseline and post-therapy were assessed. Body mass index decreased without any substantial variance after 12 weeks of piogl
... Show MoreKE Sharquie, HM Al-Hamamy, AA Noaimi, IA Al-Shawi, Journal of the Saudi Society of Dermatology & Dermatologic Surgery, 2011 - Cited by 9
Sewage water is a mixture of water and solids added to water for various uses, so it needs to be treated to meet local or global standards for environmentally friendly waste production. The present study aimed to analyze the new Maaymyrh sewage treatment plant's quality parameters statistically at Hilla city. The plant is designed to serve 500,000 populations, and it is operating on a biological treatment method (Activated Sludge Process) with an average wastewater inflow of 107,000m3/day. Wastewater data were collected daily by the Mayoralty of Hilla from November 2019 to June 2020 from the influent and effluent in the (STP) new in Maaymyrh for five water quality standards, such as (BOD5), (COD), (TSS), (TP)
... Show MoreIn this study, ultraviolet (UV), ozone techniques with hydrogen peroxide oxidant were used to treat the wastewater which is produced from South Baghdad Power Station using lab-scale system. From UV-H2O2 experiments, it was shown that the optimum exposure time was 80 min. At this time, the highest removal percentages of oil, COD, and TOC were 84.69 %, 56.33 % and 50 % respectively. Effect of pH on the contaminants removing was studied in the range of (2-12). The best oil, COD, and TOC removal percentages (69.38 %, 70 % and 52 %) using H2O2/UV were at pH=12. H2O2/ozone experiments exhibited better performance compared to
... Show MorePolycystic ovary syndrome (PCOS) is a prevalent condition in women of reproductive age. It is characterized by androgen excess and chronic anovulation. Some trace elements, macroelements, and heavy metals have been linked to pathophysiological mechanisms of PCOS .
To study the alterations in the serum levels of the trace element manganese (Mn), some macroelements, magnesium(Mg) and calcium (Ca), and the heavy metals cadmium (Cd) and lead (Pb), in obese and non-obese PCOS patients; and the association of these alterations with some of the hormonal changes occurring in PCOS.
The study was carried out at Kamal Al-Samarrai Hospital (Center for Infertility treatment and in vitro Fertilization "IVF") Baghdad- Iraq. Eig
... Show MoreIn this work, a local sunflower husk (SFH) was used as a natural surface for removing Basic Green-4 (BG4) dye, as a watersoluble pollutant. The effect of initial concentration, contact time, the mass of surface of the dye with the SFH as well as the medium temperature was studied. The application of Langmuir, Freundlich isotherms on the collected data of the adsorption process found to harmonize to Freundlich equation more than that of Langmuir. However, the adsorbed mass of BG4 dye showed a direct increase with the increase of SFH mass and equilibrium was achieved within a 60min window. The interaction of BG4 with SFH surface was spontaneous and exothermic. The empirical kinetic outcomes at ambient temperatures were applied to pseudo 1st a
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -
... Show More