Objective: To determine the effectiveness of hypothermia on renal functions for patients undergoing
coronary artery bypass graft CABG surgery.
Methodology: A purposive (non-probability) sample of (50) patients undergoing Isolated coronary artery
bypass graft surgery consecutively admitted to the surgical ward, and they were followed up in the
intraoperative, Intensive Care Unit (ICU) and in the postoperative (surgical ward). Post-operative renal function
test (glumeruler filteration rate (GFR) by using the Crockroft-Gault formula and serum creatinine level) was
determined first week post operative and post operative renal function was classified on the base of peak of
the serum creatinine level and decline of glomeruler filteration rate(GFR) as following : normal renal function
serum creatinine concentration and decline in(GFR) less than 25% from preoperative, moderate renal
dysfunction increase serum creatinine concentration and decline in(GFR) 25%-50% from preoperative, sever
renal dysfunction increase serum creatinine concentration and decline in(GFR) more than 50% from
preoperative test.
Results: results of this study show that (78%) from the sample develop post operative renal dysfunction and
the highly percentage of them are male (50%), advance age 60-70 (60%), smoking (47.0%), diabetes mellitus
DM (68%), cardiopulmonary bypass 180 and more (57.20%), New York Heart Association calcification NYHA
class III(47.5%) and patient without Intra Aortic Balloon Pump IABP(50,0%) . We conclude from the study that
highly percentage of patient undergoing isolated CABG may develop postoperative renal dysfunction even
when using hypothermic strategy as a protective measure and the patients with DM, male, advance age,
smoker, prolong time of CPB (more than 180 minutes), NYHA class III and patient without IABP are considered
as patient at high risk to develop postoperative renal dysfunction.
Recommendations: The researcher recommended that to find addition strategy rather than hypothermia
to protect renal function especially with the high risk patients during isolated CABG surgery.
(Sepak takraw) is a game that mixes football and volleyball, it is played on a court similar to a badminton court, in which players have the right to play the ball with any part of the body except the arm and hand. The object of the game is to return the ball to the opponent's court and score a point. Since it is a newly emerging game, all aspects related to it must be studied and covered in order to reach the highest levels, and it is known that each game or sporting activity has its own physical and motor capabilities, which is important to determine the level of technical performance, as the game's abilities contribute to mastering the skills. The importance of research in determining standard levels of physical and motor abilities for y
... Show MoreBuilding numerical reservoir simulation model with a view to model actual case requires enormous amount of data and information. Such modeling and simulation processes normally require lengthy time and different sets of field data and experimental tests that are usually very expensive. In addition, the availability, quality and accessibility of all necessary data are very limited, especially for the green field. The degree of complexities of such modelling increases significantly especially in the case of heterogeneous nature typically inherited in unconventional reservoirs. In this perspective, this study focuses on exploring the possibility of simplifying the numerical simulation pr
The intelligent buildings provided various incentives to get highly inefficient energy-saving caused by the non-stationary building environments. In the presence of such dynamic excitation with higher levels of nonlinearity and coupling effect of temperature and humidity, the HVAC system transitions from underdamped to overdamped indoor conditions. This led to the promotion of highly inefficient energy use and fluctuating indoor thermal comfort. To address these concerns, this study develops a novel framework based on deep clustering of lagrangian trajectories for multi-task learning (DCLTML) and adding a pre-cooling coil in the air handling unit (AHU) to alleviate a coupling issue. The proposed DCLTML exhibits great overall control and is
... Show MoreThe effects of T-shaped fins on the improvement of phase change materials (PCM) melting are numerically investigated in vertical triple-tube storage containment. The PCM is held in the middle pipe of a triple-pipe heat exchanger while the heat transfer fluid flows through the internal and external pipes. The dimension effects of the T-shaped fins on the melting process of the PCM are investigated to determine the optimum case. Results indicate that while using T-shaped fins improves the melting performance of the PCM, the improvement potential is mainly governed by the fin’s body rather than the head. Hence, the proposed T-shaped fin did not noticeably improve melting at the bottom of the PCM domain; additionally, a flat fin is ad
... Show MoreThis investigation integrates experimental and numerical approaches to study a novel solar air heater aimed at achieving an efficient design for a solar collector suitable for drying applications under the meteorological conditions of Iraq. The importance of this investigation stems from the lack of optimal exploitation of solar energy reaching the solar collector, primarily attributable to elevated thermal losses despite numerous designs employed in such solar systems. Consequently, enhancing the thermal performance of solar collectors, particularly those employed in crop drying applications, stands as a crucial focal point for researchers within this domain. Two identical double-pass solar air heaters were designed and constructed for
... Show More