Preferred Language
Articles
/
injns-123
The effect of mouth rinses on surface micro hardness of two esthetic restorative materials
...Show More Authors

Objective: To evaluate the effect of mouth rinses (Biofresh and ZAK) on the surface micro hardness
of two light cure restorative material (Tetric ceram ivoclar-vivadent) and (3M Z 250) dental
composite.
Methodology: The microhardness values of (sixty) composite specimens were measured at the top
surfaces after 24 hours of immersion in different solutions (Biofresh, Zak mouth wash and distilled
water as control). Comparison done using descriptive statistics (mean, SD, SEM, minimum and
maximum values) and inferential statistics (ANOVA and LSD) test.
Results: The biofresh mouth rinse which has high alcohol containing has less effect on
microhardness of tetric ceram than the zak &distiled water , while the effect of Zak mouth rinse on
microhhybrid composit (3M Z250) is less than biofresh &distiled water, also there was highly
significant difference between subgroup of tetric ceram and the same for (3M Z250) composite & the
effect of the mouth rinse on hardness was material dependent it may be attributed to the differences
in chemical composition and filler type of each material. Since it was found that alcohol is not the only
factor that has the softening effect on the restorative material, other ingredient in a mouth rinse. may
have softening effect on polymer matrix.
Recommendations: We recommend for a comparison of color stability for restorative material
under the effect of mouth rinsing.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 15 2021
Journal Name
Al-academy
Design and implementation of a glove theater of cardboard materials for the students of the Kindergarten Department: قيس هاشم احمد النعيمي
...Show More Authors

The current research aims to develop the skills of the kindergarten students in designing and implementing a theater for gauntlets made of cardboard materials. To study this, the researcher determined to build teaching plans for design and implementation skills according to (Kolb model).
The results of this research showed the effectiveness of teaching plans according to (Kolb's model) in developing skills of design and implementation (theater for gauntlets made of cardboard materials) for the students of the Kindergarten Department - the experimental group. Which had a positive effect to reach the desired results in the design and implementation of the gauntlet theater and dealing with cardboard materials

View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Effect Of Silicon Calcium, Boron On Proline And Relative Watiop Conference Series: Materials Science And Engineering
Effect of silicon calcium, boron on Proline and relative water contents in Apple leaves Salim, Q.T., Joody, A.T. IOP Conference Series: Materials Science and Engineering, 2018, 454(1), 012179
...Show More Authors

Publication Date
Tue Jan 01 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Experimental and numerical investigation on the behavior of reinforced reactive powder concrete two-way slabs under static load
...Show More Authors

This paper studied the behaviour of reinforced reactive powder concrete (RPC) two-way slabs under static load. The experimental program included testing three simply supported slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. Tested specimens were of identical properties except their steel fibers volume ratio (0.5 %, 1 %, and 1.5 %). Static test results revealed that, increasing steel fibers volume ratio from 0.5% to 1% and from 1% to 1.5%, led to an increase in: first crack load by (32.2 % and 52.3 %), ultimate load by (36.1 % and 17.0 %), ultimate deflection by (33.6 % and 3.4 %), absorbed energy by (128 % and 20.2 %), and the ultimate strain by (1.1 % and 6.73 %). The stiffness and ductility of the specimens also increased. A

... Show More
View Publication
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Drilling of FR-4 Composite Materials Using Single Pulse of Nd:YAG Laser
...Show More Authors

Laser drilling is capable of producing small, precisely positioned holes with high degree of reproductively. In this paper , IR millisecond Nd:YAG single pulsed laser was used to determine the effect of laser parameters on the drilled hole of the glass - fiber reinforced epoxy composite FR-4 sample of 2 mm in thickness . The type of laser source was GSI lumonics JK760TR Series laser 1.064μm system in a CNC cabin. The JK760TR series has a 0.3-50ms pulse length and a maximum repetition rate 500Hz with an average power of 600W. The investigation of single pulse laser drilling in this paper was based on theoretical and experimental solutions. In single pulse technique, the investigation included focal plane position fpp, pulse shap

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Studies on Surface Morphology and Electrical Conductivity of PS Thin Films in Presence of Divalent Complexes
...Show More Authors

       Optical properties and surface morphology of pure and doped Polystyrene films with different divalent metals of Zn, Cu and Sn and one concentration percentage have been studied. Measurements of UV-Vis spectrophotometer and AFM spectroscopy were determined. The absorbance, transmittance and reflectance spectrums were used to study different optical parameters such as absorption coefficient, refractive index, extinction coefficient and energy gap in the wavelengths rang 200-800nm. These parameters have increased in the presence of the metals. The change in the calculated values of energy gaps with doping metals content has been investigated in terms of PS matrix structural modification. The value of opt

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Dec 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Micro CT analysis of amount of dentin removal created by SAF vs. ProTaper systems
...Show More Authors

Background: Dentin removed during root canal system instrumentation for creating adequate geometry for the canal and cleaning the canal. A new instrument had been marketed with the aim of optimum shaping of all parts of the canal system, however, no information present about the amount of dentin removal compared to conventional rotary system. This study investigated the amount of dentin removal when the canal instrumented by SAF compared with ProTaper by using high resolution computed tomography (micro CT). Materials and Methods: Twenty extracted single canalled teeth were utilized for this study; and randomly divided into 2 groups. In the first group, the root canals were prepared by using protaper rotary system till F2 and the root canal

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing the Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Plant Archives
Surface epidermis of leaf and indumentum for five species of the genus Galium in Iraq
...Show More Authors

The current investigation included study of leaf surface epidermis beside indumentum for the species Galium aparine L., G. ceratopodum Boiss, G. setaceum Lam., G. spurium L., and G. tricornatum Dandy, the study showed that paracytic type of stomatal complex is the only type occur in leaf. The indumentum compose of eglandular hairs vary in their apices, length and occurrence of different part of plant body

View Publication
Scopus (1)
Scopus
Publication Date
Mon Feb 06 2023
Journal Name
Journal Of Kufa-physics
No-Core optical fibers sensor for detecting hemoglobin concentration (HB) based on the Surface Plasmon resonance.
...Show More Authors

In this work, a fiber-optic biomedical sensor was manufactured to detect hemoglobin percentages in the blood. SPR-based coreless optical fibers were developed and implemented using single and multiple optical fibers. It was also used to calculate refractive indices and concentrations of hemoglobin in blood samples. An optical fiber, with a thickness of 40 nanometers, was deposited on gold metal for the sensing area to increase the sensitivity of the sensor. The optical fiber used in this work has a diameter of 125μm, no core, and is made up of a pure silica glass rod and an acrylate coating. The length of the fiber was 4cm removed buffer and the splicing process was done. It is found in practice that when the sensitive refractive i

... Show More
View Publication Preview PDF
Crossref (1)
Crossref