The present study aimed to investigate CMV and Rubella virus as a causative agent of recurrent abortion, while the IL-2 levels were estimated as immune parameter during pregnancy period. A total of 63 blood samples were collected from recurrently aborted women, control non-pregnant women and control pregnant women. The results recorded 72.09 % CMV positive aborted women and 27.91 % Rubella virus positive aborted women. Levels of IL-2 were (437.03 ± 38.02) pg/ ml in first group, (390.51± 63.56) pg/ ml in second group, (32.98 ±15.12) pg/ ml in control group non pregnant women and (118.63 ± 24.81) pg/ ml in control pregnant women. High IL-2 levels in all studied women indicate presence of a factor affecting the immune system other than viral infection or pregnancy which may be needing more investigations.
In this paper, the researcher suggested using the Genetic algorithm method to estimate the parameters of the Wiener degradation process, where it is based on the Wiener process in order to estimate the reliability of high-efficiency products, due to the difficulty of estimating the reliability of them using traditional techniques that depend only on the failure times of products. Monte Carlo simulation has been applied for the purpose of proving the efficiency of the proposed method in estimating parameters; it was compared with the method of the maximum likelihood estimation. The results were that the Genetic algorithm method is the best based on the AMSE comparison criterion, then the reliab
... Show MoreNon Uniform Illumination biological image often leads to diminish structures and inhomogeneous intensities of the image. Algorithm has been proposed using Morphological Operations different types of structuring elements including (dick, line, square and ball) with the same parameters of (15).To correct the non-uniform illumination and enhancement biological images, the non-uniform background illumination have been removed from image, using (contrast adjustment, histogram equalization and adaptive histogram equalization). The used basic approach to extract the statistical features values from gray level of co-occurrence matrices (GLCM) can show the typical values for features content of biological images that can be in form of shape or sp
... Show MoreThe current research demonstrates the ERI method's effectiveness as a supplementary engineering site investigation approach. Engineering site research is important to indicate the subsoil of proposed production sites. The benefit of the dipole-dipole array for ERI electrical resistivity imaging is that it provides informative records of subsurface geology and condition along with profiles. The dipole-dipole array was performed along with three parallel profiles at the Diyala University site to identify the buried facilities (pipes and cables) in the area. The buried electric cable embedded in a plastic tube was used for simulation to report and verify the field resistivity results. Interpretation of field facts confirmed that
... Show MoreSummary
I wanted to address this topic because of creedal purposes importance,and its r le in regulating lives of individuals and society, and to talk about purposes of Almighty's saying:{It is easy for me},to simplify its meanings for general educated person to obtain the believe of the Creator’s power and his oneness.
Therefore,this research came,whichincludes:an introduction and topics, first :concept of creedal objectives and their divisions,second: creedal purposes in Almighty’s saying:{It is easy for me},and conclusion:in where most important results were included:
... Show MoreThe current study presents the cellar spiders genus Nita Huber & El-Hennawy, 2007 (Araneae, Pholcidae) as the first record for Iraq spider fauna, this genus represented by the species Nita elsaff Huber & El-Hennawy, 2007 were identified based on morphological characteristics and DNA sequence data. A short morphological description is also presented for cellar spiders listed in Iraq; including this species in addition to Artema Atlanta Walckenaer, 1837.
In this work the radioactive wastes in the Old Russian
Cemetery Al -Tuwaitha site were classified according to risks for
workers who are involved in the retrieval process. The exposure
assessment results expressed as estimates of radionuclide intakes by
inhalation and ingestion, exposure rates and duration for external
exposure pathways, and committed effective dose equivalents to
individuals from all relevant radionuclides and pathways. Results
showed the presence of natural radionuclides Ra-226, Th-234 and K-
40, as well as the produced radionuclide Cs-137 and Eu-152 in the
cemetery wells. The absorbed doses from the waste were classified to
two categories; exempt waste and low level waste according to
The temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show MoreIn this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies
... Show More